LOINC
Version 2.67

82926-7Phospholipase A2 receptor IgG Ab [Presence] in Serum by Line blotActive

Term Description

This term was created for, but is not limited in use to, the submitter's test strip, a membrane strip pre-coated with a specific set of antigens in parallel lines. If antibodies to any of those antigens are present in the patient's serum, they will bind to the specific antigen. The bound patient antibodies are then detected using labelled anti-human antibodies. Various manufacturers classify this method as an immunoblot technique. LOINC uses the immunoblot (IB) method to mean that some electrophoretic/chromatographic separation occurs such that position (size) of the band is part of the assessment (as in Western blot). Because this assay does not involve a separation step but rather uses strips with pre-fixed antigens, the LOINC Method is Line blot.
Source: Regenstrief LOINC

Part Description

LP172674-6   Phospholipase A2 receptor Ab.IgG
The M-type phospholipase A2 receptor (PLA2R) stimulates the production of phospholipase A2 receptor autoantibodies. The PLA2R antibodies are a sensitive biomarker for idiopathic membranous nephropathy (MN). Over 80% of patients with MN are positive for PLA2R antibodies. MN is a syndrome where immune complexes deposit on the basement membrane and along with complement fixation alter the filtration barrier leading to proteinuria. The target antigens reside on the podocytes and is where the disease process begins. PLA2R antibodies are useful to diagnose and monitor treatment of MN. [PMCID: PMC3103733] Source: Regenstrief LOINC

Fully-Specified Name

Component
Phospholipase A2 receptor Ab.IgG
Property
PrThr
Time
Pt
System
Ser
Scale
Ord
Method
Line blot

Additional Names

Short Name
PLA2R IgG Ser Ql Line blot
Display Name
Phospholipase A2 receptor IgG Line blot Ql (S)

Basic Attributes

Class
SERO
Type
Laboratory
First Released
Version 2.58
Last Updated
Version 2.66
Change Reason
This term was created for an assay that uses a membrane strip pre-coated with a specific set of antigens in parallel lines. Because the antigens are seperated by electrophoresis/chromatographic separation during manufacturing, not during the test procedure itself, this test was assigned a LOINC Method of Immunoassay (IA) and not Immunoblot (IB). However, upon further review of IA, IB, and Immunoblot strip methodologies and regulatory distinctions between these, we changed the Method from IA to Line blot so that users can distinguish between these three Methods. The meaning of the term has not changed since it was created for an IB strip assay as described in the term description.
Order vs. Observation
Both

Example Answer List LL360-9

Source: Regenstrief Institute

Answer Code Score Answer ID
Positive Copyright http://snomed.info/sct ID:10828004 Positive (qualifier value) LA6576-8
Negative Copyright http://snomed.info/sct ID:260385009 Negative (qualifier value) LA6577-6

Member of these Groups

LG31602-2 Phospholipase A2 receptor Ab.IgG|PrThr|Pt|ANYBldSerPl

Language Variants Get Info

zh-CNChinese (CHINA)
磷脂酶 A2 受体 抗体.IgG:存在情况或阈值:时间点:血清:序数型:线点印迹法
nl-NLDutch (NETHERLANDS)
fosfolipase A2-receptor As.IgG:aanwezigheid:moment:serum:ordinaal:lijnblot
fr-FRFrench (FRANCE)
Phospholipase A2 récepteur anticorps IgG:Présence/Seuil:Ponctuel:Sérum:Qualitatif:Blot en ligne
es-ESSpanish (SPAIN)
Receptor fosfolipasa A2 IgG:PrThr:Punto temporal:Suero:Ord:Line blot