LOINC
Version 2.73

99707-2Continuous renal replacement therapy panelActive

Term Description

This panel includes terms to report results related to continuous renal replacement therapy, including parameters related to the pressures, volumes and rates of various components in the dialysis circuit, information about the patient's dialysis access, and lab results. Continuous renal replacement therapy (CRRT) is typically prescribed for critically ill patients and runs continuously for 24 hours/day. This is in contrast to intermittent hemodialysis, which is typically performed three times a week for several hours. CRRT may be used to remove solutes, fluid, or both. It is commonly prescribed for patients with acute renal failure and is also used to treat patients with septic shock.[PMID:18360553]
Source: Regenstrief LOINC

Panel Hierarchy
Details for each LOINC in Panel LHC-Forms

LOINC Name R/O/C Cardinality Example UCUM Units
99707-2 Continuous renal replacement therapy panel
Indent57835-1 Appearance of Dialysis fluid
Indent51617-9 Color of Dialysis fluid
Indent12457-8 Volume of Dialysis fluid mL
Indent53654-0 pH of Dialysis fluid [pH]
Indent5919-6 Creatinine [Mass/volume] in Dialysis fluid mg/dL
Indent2343-2 Glucose [Mass/volume] in Dialysis fluid mg/dL
Indent2775-5 Phosphate [Mass/volume] in Dialysis fluid mg/dL
Indent2820-9 Potassium [Moles/volume] in Dialysis fluid mmol/L
Indent5920-4 Protein [Mass/volume] in Dialysis fluid g/L
Indent2949-6 Sodium [Moles/volume] in Dialysis fluid mmol/L
Indent45302-7 Urea [Moles/volume] in Dialysis fluid mmol/L
Indent5918-8 Urea nitrogen [Mass/volume] in Dialysis fluid mg/dL
Indent99708-0 Continuous renal replacement therapy mode Renal replacement therapy circuit
Indent99709-8 Continuous renal replacement therapy fluid removal goal [Volume] 1 hour mL
Indent99710-6 Venous lumen volume Dialysis catheter mL
Indent99711-4 Blood flow rate Renal replacement therapy circuit mL/min
Indent99712-2 Dialysate flow rate Renal replacement therapy circuit mL/min
Indent99713-0 Post-filter replacement fluid rate Renal replacement therapy circuit mL/min
Indent99714-8 Pre-filter replacement fluid rate Renal replacement therapy circuit mL/min
Indent99715-5 Dialysis access site
Indent99716-3 Dialysis access site appearance
Indent99717-1 Access pressure Renal replacement therapy circuit mm[Hg]
Indent99718-9 Effluent pressure Renal replacement therapy circuit mm[Hg]
Indent99719-7 Filter pressure Renal replacement therapy circuit mm[Hg]
Indent99720-5 Transmembrane pressure Renal replacement therapy circuit mm[Hg]
Indent99721-3 Return pressure Renal replacement therapy circuit mm[Hg]
Indent99731-2 Pressure drop Renal replacement therapy circuit mm[Hg]
Indent99732-0 Dialysate fluid Renal replacement therapy circuit
Indent99733-8 Replacement fluid Renal replacement therapy circuit
Indent99734-6 Arterial lumen volume Dialysis catheter mL
Indent99735-3 Ultrafiltrate volume removed 1 hour mL
Indent72050-8 Dialysis access
Indent99736-1 Reason for filter change Renal replacement therapy circuit

Fully-Specified Name

Component
Continuous renal replacement therapy panel
Property
-
Time
Pt
System
^Patient
Scale
-
Method

Additional Names

Short Name
CRRT panel

Basic Attributes

Class
PANEL.CLIN
Type
Clinical
First Released
Version 2.72
Last Updated
Version 2.72
Order vs. Observation
Order
Panel Type
Convenience group

Language Variants Get Info

zh-CNChinese (China)
连续性肾脏替代治疗组套:-:时间点:^患者:-:
it-ITItalian (Italy)
Terapia renale sostitutiva continua, panel:-:Pt:^Paziente:-:

LOINC FHIR® API Example - CodeSystem and Questionnaire Requests Get Info

https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=99707-2 https://fhir.loinc.org/Questionnaire/?url=http://loinc.org/q/99707-2