Term Description

D-dimer is considered a coagulation or hemostasis assay and will usually require platelet poor plasma (PPP); tests done on whole blood are the exception. Some assays do not specify PPP (e.g. VIDAS D-Dimer Exclusion II, Biomerieux, Inc) per se but the whole blood is spun down to yield plasma, which will be low in platelets. Spinning is the most common way to obtain plasma low in platelets.

Part Description

LP15987-8   Fibrin D-dimer
D-dimer is elevated in disseminated intravascular coagulation (DIC), deep vein thrombosis (DVT), and pulmonary embolism (PE). Source: Regenstrief Institute

LOINC Names Get Info

Fully-Specified Name
Fibrin D-dimer:MCnc:Pt:PPP:Qn:IA.FEU
Long Common Name
Fibrin D-dimer [Mass/volume] in Platelet poor plasma by Immunoassay.FEU
Short Name
D Dimer PPP IA.FEU-mCnc
Display Name
Fibrin D-dimer IA.FEU (PPP) [Mass/Vol]
Consumer Name Alpha Get Info
Fibrin d-dimer, Blood

Part Model Get Info

  • Component
    Fibrin D-dimer
    LP15987-8
    • Analyte
      Fibrin D-dimer
      LP15987-8
      • Component Numerator
        Fibrin D-dimer
        LP15987-8
        • Component Numerator Core
          Fibrin D-dimer
          LP15987-8
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    MCnc
    LP6827-2
  • Time
    Pt
    LP6960-1
  • System
    PPP
    LP7494-0
    • System Core
      PPP
      LP7494-0
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    IA.FEU
    LP443378-7

Basic Attributes

Class
COAG
Type
Laboratory
First Released
Version 2.21
Last Updated
Version 2.79 (NAM)
Change Reason
Release 2.79: METHOD_TYP: Change due to change in modeling heuristics as result of collaboration with SCT, and potential improvement in preparation for post-coordination; COMPONENT: Change due to change in modeling heuristics as result of collaboration with SCT, and potential improvement in preparation for post-coordination; LONG_COMMON_NAME: Change due to change in modeling heuristics as result of collaboration with SCT, and potential improvement in preparation for post-coordination; SHORTNAME: Change due to change in modeling heuristics as result of collaboration with SCT, and potential improvement in preparation for post-coordination; Previous Releases: The EIA method, which was always intended to cover more than just enzyme-linked immunoassay and whose display name for the long common name has always been Immunoassay, was renamed IA in order to eliminate ambiguity about whether the method has a broader meaning than just enzyme-linked immunoassay. Likewise, EIA.rapid was renamed IA.rapid. These changes were approved by the Laboratory LOINC Committee in June 2016.
Order vs. Observation
Both
Common Test Rank Get Info
2555

Member of these Panels

LOINCLong Common Name
98125-8Intravascular coagulation and fibrinolysis panel
112626-7Liver Transplant intraoperative panel - Specimen

Member of these Groups Get Info

LOINC GroupGroup Name
LG52053-2Fibrin D-dimer|Pt|ANYBldPPP

Language Variants Get Info

TagLanguageTranslation
cs-CZCzech (Czechia)D-dimer fibrinu FEU (fibrinogen equivalent units):Hmotnostní koncentrace:Časový bod:Plazma chudá na trombocyty:Kvantitativní:Imunoanalýza
de-DEGerman (Germany)Fibrin D-Dimer:Massenkonzentration:Zeitpunkt:Thrombozytenarmes Plasma:Quantitativ:Immunoassay.FEU
es-ESSpanish (Spain)Dimero D de fibrina:Concentración de masa:Punto temporal:Plasma pobre en plaquetas:Qn:FEU mediante inmunoensayo
Synonyms: Cuantitativo Inmunoensayo. Unidades Equivalentes de Fibrinógeno Unidades Equivalentes de Fibrinógeno
es-MXSpanish (Mexico)Dímero D de fibrina FEU:Concentración de masa:Punto temporal:Plasma pobre en plaquetas:Cuantitativo:Inmunoensayo
fr-CAFrench (Canada)D-dimère de fibrine:Concentration de masse:Temps ponctuel:Plasma pauvre en plaquettes:Quantitatif:Immunodosage.FEU
fr-FRFrench (France)D-Dimères:Masse/Volume:Ponctuel:Plasma pauvre en plaquettes:Numérique:Immunoanalyse FEU
it-ITItalian (Italy)Fibrina D-dimero:MCnc:Pt:PPP:Qn:IA.FEU
Synonyms: Concentrazione di Massa FEU Immunoassay Immunoassay.FEU Plasma povero di piastrine Punto nel tempo (episodio) Studio di coagulazione
nl-NLDutch (Netherlands)fibrine D-dimeer FEU:massa/volume:moment:plaatjesarm plasma:kwantitatief:immunoassay
Synonyms: coagulatiemethode IA
pl-PLPolish (Poland)D-dimer fibryny:stężenie masowe:punkt w czasie:osocze ubogopłytkowe:ilościowy:metoda immunologiczna.FEU
Synonyms: D-dimer jednostka ekwiwalentu fibrynogenu metoda immunologiczna.jednostka ekwiwalentu fibrynogenu PPP
pt-BRPortuguese (Brazil)Dímero-D fibrina FEU:MCnc:Pt:PPPQ:Qn:Imunoensaio
Synonyms: Fragment D-dimer; Rhesus; Rh; Mass concentration; Level; Point in time; Random; Platelet poor plasma; Plas; Quantitative; QNT; Quant; Quan; Enzyme immunoassay; ELISA; MEIA; SUDS; ELFA; IAA; COAGULATION
uk-UAUkrainian (Ukraine)D-димер Фібрину FEU (Фібриноген Еквівалентні Одиниці):Масова Концентрація:МоментЧасу:Бідна тромбоцитами плазма:Кількісно:Імуноаналіз
Synonyms: COAGULATION; D Dimer; D dimer FEU; Dextro; EIA; ELFA; ELISA; Enzyme immunoassay; Fragment D-dimer; Hematology; Heme; IAA; Level; Mass concentration; MEIA; Plas; Platelet poor plasma; Point in time; QNT; Quan; Quant; Quantitative; Random; SUDS
zh-CNChinese (China)纤维蛋白 D-二聚体:质量浓度:时间点:贫血小板血浆:定量型:免疫测定法.FEU
Synonyms: D-二聚体;D-二聚体片段;二聚体片段;纤维蛋白二聚体 Rh;Rhesus;恒河猴;猕猴;罗猴 乏血小板血浆;Platelet poor plasma;PPP 免疫测定;免疫分析法;免疫检定法;免疫检定;免疫试验;酶免疫测定法;酶免疫测定;酶免疫分析法;酶免疫检定法;酶免疫检定;酶免疫试验 免疫测定法(IA、免疫分析、免疫检定、免疫试验).FEU(纤维蛋白 D-二聚体 FEU、D 二聚体 FEU) 凝血功能;凝血功能试验;凝血过程;血液凝固;血液凝固功能;血液凝固过程 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 时刻;随机;随意;瞬间 水平;浓度;质量浓度(单位体积) 纤维蛋白 D-二聚体 FEU;D 二聚体 FEU

Example Units

UnitSource
ug/mL{FEU}Example UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=48067-3