59261-8
Hemoglobin A1c/Hemoglobin.total in Blood by IFCC protocol
Active
Term Description
This term is not proposed for use in the United States, who will continue to use the NGSP protocol and report the Hgb A1c as %.
Hemoglobin A1c measured using IFCC reference materials. The International Federation of Clinical Chemistry Working Group (IFCC-WG) on HbA1c has recommended a new approach to HbA1c analysis that uses mass spectroscopy and capillary electrophoresis as the reference methods, and set of reference laboratories that use prepared mixtures of purified Hemoglobin A1c and HbA0 as calibrators. (http://www.ngsp.org/prog/IFCCstd.pdf). The IFCC method is reported as millimoles/Mole - which resolves to units that are ten times the value of a pure fraction. The value number produced by the IFCC method differs by less than a factor of ten from the NGSP approach which has been the standard in clinical care since DCCT/UKPDS diabetes studies. A value of 6% under the NGSP method would be 42.8 millimole/mole when tested by the IFFCC approach (per the conversion formula in the above reference). Many countries will report the IFCC value along with the NGSP values and the estimated average glucose - at least for a time. In the US the policies are not as clear and there is at least a chance of no change in the current reporting style will occur. (Source- many- written by CJM 2010 04 27).
Source: Regenstrief Help
Part Description
LP16413-4 Hemoglobin A1c
Currently (2010), four standardization protocols exist for measuring Hgb A1c:
1. IFCC - designated as a Reference Method or RM (http://www.ifcchba1c.net/)
2. NGSP - the long standing protocol used in the US and most other countries since the DCCT study (http://www.ngsp.org/factors.asp)
3.JDS/JSCC - a protocol used in Japan, Spain and possibly other countries
4. Swedish - used in Sweden at least
Protocols 2-4 are known as Designated Comparison Methods (DCM) and have been connected to the Reference Method and each other through various regression equations.
Because of the high degrees of standardization within protocol it should no longer be necessary to specify a LOINC code with a method such as "HPLC", "electrophoresis" or anything else. Analytical instruments will be designed so that an Hgb A1c result can be traced back to a specific standardization protocol, so the important distinction will be the standardization protocol as described above and which will be carried in the method field.
A meeting of instrument manufacturers (presumably including Japanese) in Milan, Italy, December 12, 2007, agreed (among other items) that:
-All manufacturers should implement worldwide the traceability to the IFCC reference system for Hgb -A1c.
-All new instruments sold after January 1st, 2011 will report (as a result of an Hgb A1c test) both SI (mmol/mol - no decimals) and NGSP derived units (percentage - one decimal), in agreement with the Consensus Statement.
-Note they only committed to supporting protocol (1) and (2)
Different countries are adopting the international harmonization recommendations in different ways. We have information from the NGSP that the US will continue to report only Hgb A1c/NGSP, with the unit percent - i.e., no change. In Great Britain, labs have already started to report all results both as Hgb A1c (NGSP) in % and Hgb A1c (IFCC) in mmol/mol. In Canada, they are awaiting a recommendation from an expert panel. Any of these measures could be reported in the same units, but the convention for the reporting Hgb A1c under the new IFCC protocol will be to use units of mmol/mol to avoid confusion between the DCCT/NGSP and the IFFCC protocol.
LOINC has defined 59261-8 (Hemoglobin A1c/Hemoglobin.total in Blood) by IFCC protocol.
These protocols produce different results when expressed in the same units. For example, the equivalent of Hgb A1c (NGSP) of 6.5% is Hgb A1c (IFCC) is 4.8%.
The NGSP web site (http://www.ngsp.org/factors.asp) suggests the use of alternate measures, such as glycated albumen, for patients with severe iron deficiency, dialysis patients, and those with SS SC CC because of over or under reading that can occur with these interferences. It also describes the effect of abnormal hemoglobins on results of HbA1c by instrument.
Studies have demonstrated racial and ethnic differences in the relationship between glucose levels and hemoglobin A1C [22238408], and it has been suggested that some descendants of sub-Saharan Africa may have higher levels of measured hemoglobin A1C compared to glucose levels due to hemoglobin variants PMID: 31675503.
Source: Regenstrief Help
Reference Information
Type | Source | Reference |
---|---|---|
Webcontent | Lab Tests Online®Copyright Copyright © 2021 Lab Tests Online. All rights reserved. | Hemoglobin A1c |
Fully-Specified Name
- Component
- Hemoglobin A1c/Hemoglobin.total
- Property
- SFr
- Time
- Pt
- System
- Bld
- Scale
- Qn
- Method
- IFCC
Additional Names
- Long Common Name
- Hemoglobin A1c/Hemoglobin.total in Blood by IFCC protocol
- Short Name
- HbA1c SFr Bld IFCC
- Display Name
- HbA1c IFCC protocol (Bld) [Molar fraction]
- Consumer Name Alpha Get Info
- HbA1c/Total Hgb, Blood
Basic Attributes
- Class
- CHEM
- Type
- Laboratory
- First Released
- Version 2.32
- Last Updated
- Version 2.73 (MIN)
- Change Reason
- Release 2.70: CLASS: Changed Class from HEM/BC to CHEM as A1C tests are more correctly classified in CHEM.;
- Order vs. Observation
- Both
- Common Test Rank Get Info
- 2804
Member of these Panels
LOINC | Long Common Name |
---|---|
67767-4 | HEDIS 2012 panel |
72199-3 | HEDIS 2013 panel |
74234-6 | HEDIS 2014 Value Sets |
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
de-AT | German (Austria) | Synonyms: Hämoglobin A1c IFCC |
de-DE | German (Germany) | Hämoglobin A1c/Hämoglobin.gesamt: Synonyms: HbA1c |
el-GR | Greek (Greece) | Αιμοσφαιρίνη A1c/Αιμοσφαιρίνη.ολική: Synonyms: SFr Αιμοσφαιρίνη Αιμοσφαιρίνη A1c |
es-ES | Spanish (Spain) | Hemoglobina A1c (Hemoglobina glicosilada)/Hemoglobina.total: Synonyms: Cuantitativo |
es-MX | Spanish (Mexico) | Hemoglobina A1c / Hemoglobina total: |
fr-CA | French (Canada) | Hémoglobine A1c/Hémoglobine.totale: |
fr-FR | French (France) | Hémoglobine A1c/hémoglobine totale: |
fr-BE | French (Belgium) | Hémoglobine A1c/Hémoglobine.totale: Synonyms: Fraction. Concentration Hb Hb.totale HbA1c International Federation Clinical Chemistry |
it-IT | Italian (Italy) | Emoglobina A1c/Emoglobina.totale: Synonyms: Chimica Emoglobina A1c (HgB glicata ) Frazione di Sostanza Protocollo IFCC Punto nel tempo (episodio) Sangue |
nl-NL | Dutch (Netherlands) | hemoglobine A1c/hemoglobine.totaal: |
pl-PL | Polish (Poland) | Hemoglobina A1c/hemoglobina całkowita: Synonyms: Hemoglobina A1c/Hemoglobina całkowita |
pt-BR | Portuguese (Brazil) | Hemoglobina A1c/Hemoglobina.total: |
tr-TR | Turkish (Turkey) | Hemoglobin A1c/Hemoglobin.total: |
uk-UA | Ukrainian (Ukraine) | Гемоглобін A1c/Гемоглобін.загальний: Synonyms: Blood; |
zh-CN | Chinese (China) | 血红蛋白 A1c/血红蛋白.总计: Synonyms: GHb; |
Example Units
Unit | Source |
---|---|
% | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=59261-8
LOINC Copyright
Copyright © 2025 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://