82936-6
Signal Recognition Particle (SRP) IgG Ab [Presence] in Serum by Line blot
Active
Term Description
This term was created for, but is not limited in use to, the submitter's test strip, a membrane strip pre-coated with a specific set of antigens in parallel lines. If antibodies to any of those antigens are present in the patient's serum, they will bind to the specific antigen. The bound patient antibodies are then detected using labelled anti-human antibodies. Various manufacturers classify this method as an immunoblot technique. LOINC uses the immunoblot (IB) method to mean that some electrophoretic/chromatographic separation occurs such that position (size) of the band is part of the assessment (as in Western blot). Because this assay does not involve a separation step but rather uses strips with pre-fixed antigens, the LOINC Method is Line blot.
Source: Regenstrief LOINC
Part Description
LP31710-4 Signal recognition particle
A cytosolic ribonucleoprotein complex that acts to induce elongation arrest of nascent presecretory and membrane proteins until the ribosome becomes associated with the rough endoplasmic reticulum. It consists of a 7S RNA and at least six polypeptide subunits (relative molecular masses 9, 14, 19, 54, 68, and 72K).
Source: National Library of Medicine, MeSH 2006
Fully-Specified Name
- Component
- Signal recognition particle Ab.IgG
- Property
- PrThr
- Time
- Pt
- System
- Ser
- Scale
- Ord
- Method
- Line blot
Additional Names
- Short Name
- SRP IgG Ser Ql Line blot
- Display Name
- Signal Recognition Particle (SRP) IgG Line blot Ql (S)
- Consumer Name Alpha Get Info
- Signal Recognition Particle (SRP) IgG antibody, Blood
Example Answer List: LL2010-8
Source: Estonian Society of Laboratory MedicineAnswer | Code | Score | Answer ID |
---|---|---|---|
PositiveCopyright http://snomed.info/sct ID:10828004 Positive (qualifier value) | LA6576-8 | ||
NegativeCopyright http://snomed.info/sct ID:260385009 Negative (qualifier value) | LA6577-6 | ||
Borderline | LA4259-3 |
Basic Attributes
- Class
- SERO
- Type
- Laboratory
- First Released
- Version 2.58
- Last Updated
- Version 2.66
- Change Reason
- This term was created for an assay that uses a membrane strip pre-coated with a specific set of antigens in parallel lines. Because the antigens are seperated by electrophoresis/chromatographic separation during manufacturing, not during the test procedure itself, this test was assigned a LOINC Method of Immunoassay (IA) and not Immunoblot (IB). However, upon further review of IA, IB, and Immunoblot strip methodologies and regulatory distinctions between these, we changed the Method from IA to Line blot so that users can distinguish between these three Methods. The meaning of the term has not changed since it was created for an IB strip assay as described in the term description.
- Order vs. Observation
- Both
Member of these Panels
LOINC | Long Common Name |
---|---|
97561-5 | Necrotizing myopathy autoimmune Ab panel - Serum |
Member of these Groups Get Info
LOINC Group | Group Name |
---|---|
LG51136-6 | Signal recognition particle Ab.IgG| |
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
es-ES | Spanish (Spain) | Particula de reconocimiento de señal (SRP) IgG: |
es-MX | Spanish (Mexico) | Partícula de reconocimiento de señal Ab.IgG: |
fr-CA | French (Canada) | Particule reconnaissance signal, IgG: |
fr-FR | French (France) | SRP anticorps IgG: |
it-IT | Italian (Italy) | Particella di riconoscimento del segnale Ab.IgG: Synonyms: anticorpi IgG anticorpo Particella di Riconoscimento del Segnale (SRP) Presenza o Soglia Punto nel tempo (episodio) Siero Sierologia (anticorpi e la maggior parte degli ant |
nl-NL | Dutch (Netherlands) | signaalherkenningsdeeltje As.IgG: Synonyms: antistof; |
pl-PL | Polish (Poland) | Cząsteczka rozpoznająca sygnał Ab.IgG: Synonyms: Cząsteczka rozpoznająca sygnał IgG Przeciwciała do cząsteczek rozpoznających sygnał Przeciwciała IgG do cząsteczek rozpoznających sygnał |
zh-CN | Chinese (China) | 信号识别颗粒 抗体.IgG: Synonyms: Ab.IgG; |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=82936-6
Third Party Copyright
This material includes SNOMED Clinical Terms® (SNOMED CT®) which is used by permission of the International Health Terminology Standards Development Organisation (IHTSDO) under license. All rights reserved. SNOMED CT® was originally created by The College of American Pathologists. "SNOMED" and "SNOMED CT" are registered trademarks of the IHTSDO.
This material includes content from the US Edition to SNOMED CT, which is developed and maintained by the U.S. National Library of Medicine and is available to authorized UMLS Metathesaurus Licensees from the UTS Downloads site at https://uts.nlm.nih.gov.
Use of SNOMED CT content is subject to the terms and conditions set forth in the SNOMED CT Affiliate License Agreement. It is the responsibility of those implementing this product to ensure they are appropriately licensed and for more information on the license, including how to register as an Affiliate Licensee, please refer to http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org<mailto:info@snomed.org>. This may incur a fee in SNOMED International non-Member countries.
LOINC Copyright
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright