Part Descriptions

LP202951-2   Pressure half time.diastole
Pressure half-time is the time needed for the atrioventricular pressure gradient to reduce to half its initial measurement during ventricular diastole. It is primarily assessed through Doppler echocardiography though more invasive cardiac catherization and provides a means of calculating the approximate mitral valve area and evaluating mitral valve stenosis regurgitation. Caution should be used when applying pressure half-time measurements in patients with prosthetic mitral valves, mitral commissurotomy, tachycardia, arrhythmias, and aortic insufficiency. PMID: 21044983 Source: Regenstrief LOINC

LP6617-7   US.doppler
Doppler ultrasound detects the shift in frequency of ultrasound signals reflected from moving objects. Conventional Doppler techniques assess the velocity of blood flow by measuring high-frequency, low-amplitude signals from small, fast-moving blood cells. PMID: 16534017 Source: Regenstrief LOINC, PMID: 16534017

LOINC Names Get Info

Fully-Specified Name
Pressure half time.diastole:Time:Pt:Mitral valve:Qn:US.doppler
Long Common Name
Mitral valve Pressure half time during diastole by US.doppler
Short Name
MV PHT dias

Part Model Get Info

  • Component
    Pressure half time.diastole
    LP202951-2
    • Analyte
      Pressure half time.diastole
      LP202951-2
      • Component Numerator
        Pressure half time.diastole
        LP202951-2
        • Component Numerator Core
          Pressure half time.diastole
          LP202951-2
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Time
    LP6879-3
  • Time
    Pt
    LP6960-1
  • System
    Mitral valve
    LP7424-7
    • System Core
      Mitral valve
      LP7424-7
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    US.doppler
    LP6617-7

Basic Attributes

Class
CARD.US.DICOM
Type
Clinical
First Released
Version 2.54
Last Updated
Version 2.67 (MIN)
Order vs. Observation
Observation

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Χρόνος υποδιπλασιασμού πίεσης.διαστολή:Time:Pt:Μιτροειδής βαλβίδα:Qn:Υπερηχογράφημα.doppler
Synonyms: CARD.US CARD.US.DICOM Pt Qn Time ΗΠΑ Μιτροειδής βαλβίδα Πίεση Υπερηχογράφημα.doppler Χρόνος ημίσειας πίεσης Χρόνος υποδιπλασιασμού πίεσης.διαστολή
es-MXSpanish (Mexico)Presión medio tiempo diástole:Tiempo:Punto temporal:La válvula mitral:Cuantitativo:US.doppler
it-ITItalian (Italy)Pressione metà del tempo.diastole:Tempo:Pt:Valvola mitrale:Qn:Eco.doppler
Synonyms: DICOM Simplified Adult Echo Report concepts Eco Ecografia cardiaca Ecografia.doppler Emitempo di pressione Punto nel tempo (episodio) Tempo (e.g. secondi)
zh-CNChinese (China)压力减半时间.舒张期:时间:时间点:二尖瓣:定量型:超声.多普勒
Synonyms: 僧帽瓣 压力(压差、压强)减半(半减、半衰、半寿、降半、半降)时间(期).舒张期(心脏舒张期、心舒期) 压差降半时间;压差半降时间;压力减半时间;压力半减时间;压差半减时间 压强 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 心脏病学 心脏病学.超声;心脏超声 心脏超声.多普勒 时刻;随机;随意;瞬间 时间(如秒);时间(如秒数) 超声检查方法;超声检查法;超声波;超声波检查方法;超声波检查法

Example Units

UnitSource
msExample UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=79912-2