Part Description

LP203206-0   PISA radius.diastole
The Proximal Isovelocity Surface Area (PISA) method is based on convergent flow dynamics and the Continuity Principle. Proximal to the orifice, flow converges in hemispheric layers of equal velocity. The flow rate across any of these hemispherical isovelocity surfaces is equal to the area of the surface (which can be calculated from its radius) multiplied by the flow velocity at the surface. Choosing a PISA velocity equal to the aliasing velocity of the system is an easy way to visualize an isovelocity surface (which will appear as the surface where the Doppler color switches between red and blue) and measure the corresponding PISA radius from the center of the orifice to the surface. The Continuity Principle states that in the absence of a leak or additional flow into a conduit, the flow rate will be constant along the length of the conduit, whether the conduit is the heart or the regurgitant jet. So the flow rate through the regurgitant orifice is the same as the flow rate across the PISA surface. Dividing the flow rate by the peak velocity through the orifice (measured using continuous wave Doppler of the regurgitant jet) provides the effective regurgitant orifice area (EROA). Source: DICOM

LOINC Names Get Info

Fully-Specified Name
PISA radius.diastole:Len:Pt:Aortic valve:Qn:US.2D+doppler
Long Common Name
Aortic valve PISA radius during diastole [Length] by US.2D+doppler
Short Name
AV PISA radius dias US.2D+DOP

Part Model Get Info

  • Component
    PISA radius.diastole
    LP203206-0
    • Analyte
      PISA radius.diastole
      LP203206-0
      • Component Numerator
        PISA radius.diastole
        LP203206-0
        • Component Numerator Core
          PISA radius.diastole
          LP203206-0
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Len
    LP6822-3
  • Time
    Pt
    LP6960-1
  • System
    Aortic valve
    LP7026-0
    • System Core
      Aortic valve
      LP7026-0
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    US.2D+doppler
    LP203247-4

Basic Attributes

Class
CARD.US.DICOM
Type
Clinical
First Released
Version 2.54
Last Updated
Version 2.67 (MIN)
Order vs. Observation
Observation

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Ακτίνα PISA.διαστολή:Len:Pt:Αορτική βαλβίδα:Qn:Υπερηχογράφημα.2D+doppler
Synonyms: CARD.US CARD.US.DICOM Len Pt Qn US.2D Ακτίνα PISA.διαστολή Αορτική βαλβίδα ΗΠΑ Κερκίδα Υπερηχογράφημα.2D+doppler
es-MXSpanish (Mexico)Radio PISA diástole:Len:Punto temporal:Valvula aortica:Cuantitativo:US.2D+doppler
it-ITItalian (Italy)Raggio PISA.diastole:Len:Pt:Valvola aortica:Qn:Eco.2D+doppler
Synonyms: DICOM Simplified Adult Echo Report concepts Eco Ecografia 2D Ecografia cardiaca Lunghezza Punto nel tempo (episodio) Raggio PISA durante diastole
zh-CNChinese (China)PISA 半径.舒张期:长度:时间点:主动脉瓣:定量型:超声.2D+多普勒
Synonyms: PISA 半径(半径范围、半径长度).舒张期(心脏舒张期、心舒期);舒张期(心脏舒张期、心舒期)过程中(当中、期间)的PISA 半径(半径范围、半径长度);近端等速表面积;近端等速表面积法;近心端等速表面积;Proximal Isovelocity Surface Area;PISA;PISA法;血流汇聚法 二维超声;二维超声检查;超声.二维;超声检查.2D;超声检查.二维 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 心脏病学 心脏病学.超声;心脏超声 时刻;随机;随意;瞬间 桡骨 超声.二维+多普勒 超声检查方法;超声检查法;超声波;超声波检查方法;超声波检查法 近端等速表面积 近端等速表面积(Proximal Isovelocity Surface Area,PISA) 长;长短

Example Units

UnitSource
cmExample UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=79945-2