104641-6
Time below range, low in Reporting Period Interstitial fluid by calculation
Active
LOINC Names Get Info
- Fully-Specified Name
- Time below range, low:
TimeFr: RptPeriod: Interstitial fluid: Qn: Calculated - Long Common Name
- Time below range, low in Reporting Period Interstitial fluid by calculation
- Short Name
- Time hypoglycemic RptPrd Intrsttl
- Display Name
- Time below range, low Calc (Reporting Period Interstitial fluid)
- Consumer Name Alpha Get Info
- Time below range, low, Interstitial fluid
Part Model Get Info
- Component
- Time below range, low
LP441038-9
- Analyte
- Time below range, low
LP441038-9
- Component Numerator
- Time below range, low
LP441038-9
- Component Numerator Core
- Time below range, low
LP441038-9
- Component Numerator Core Suffix
- NULL
- Component Denominator
- NULL
- Component Denominator Core
- NULL
- Component Denominator Core Suffix
- NULL
- Challenge
- NULL
- Adjustment
- NULL
- Count
- NULL
- Property
- TimeFr
LP185982-8
- Time
- RptPeriod
LP190654-6
- Time Core
- RptPeriod
LP190654-6
- Time Modifier
- NULL
- System
- Interstitial fluid
LP426918-1
- System Core
- Interstitial fluid
LP426918-1
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- Calculated
LP6165-7
Survey Question
- Text
- Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent below target glucose range, low (TBR-L) 54-69 mg/dL (3.0-3.8 mmol/L) (hypoglycemic) during reporting period.
Basic Attributes
- Class
- CHEM
- Type
- Laboratory
- First Released
- Version 2.79
- Last Updated
- Version 2.79 (ADD)
- Order vs. Observation
- Observation
Formula (Readable)
(TBR-L) 54-69 mg/dL (3.0-3.8 mmol/L)
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 106793-3 | Continuous glucose monitoring time in ranges panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| es-ES | Spanish (Spain) | Tiempo por debajo del rango, bajo: Synonyms: Cuantitativo |
| fr-FR | French (France) | Fraction de temps passé au-dessous des valeurs cibles de glucose, valeur basse: |
| it-IT | Italian (Italy) | Tempo sopra il range, basso: Synonyms: Chimica Frazione di Tempo Tempo sopra l''intervallo, basso |
| zh-CN | Chinese (China) | 低于范围的时间, 低: Synonyms: 低于范围(正常参考范围、 |
Example Units
| Unit | Source |
|---|---|
| % | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://