22003-8
Site and laterality and morphology override flag Cancer case
Active
Term Description
Some computer edits identify errors. Others indicate possible errors that require manual review for resolution. To eliminate the need to review the same cases repeatedly, over-ride flags have been developed to indicate that data in a record (or records) have been reviewed and, while unusual, are correct. This over-ride is used with the following edits in the NAACCR Metafile of the EDITS software: Laterality, Primary Site, Morphology (NAACCR IF42) Laterality, Primary Site, Morphology (SEER IF42) Laterality, Primary Site, Morph ICDO3 (NAACCR IF42) Laterality, Primary Site, Morph ICDO3 (SEER IF42)
Some edits check for code combinations that are possible, but quite rare. If the code combination generates an error message and review of the case indicates that the codes are correct for the case, then the over-ride flag is used to skip the edit in the future. See Chapter IV, Recommended Data Edits and Software Coordination of Standards. Over-ride Flag as Used in the EDITS Software Package Edits of the type Laterality, Primary Site, Morph differ in whether they produce a warning or an error message and in use of ICD-O-2 (including the Field Trial Editions) or ICD-O-3 morphology and do the following: If the Primary Site is a paired organ and Behavior is in situ (2), then laterality must be 1, 2, or 3. If diagnosis year less than 1988 and histology >= 9590, no further editing is performed. If diagnosis year greater than 1987 and histology = 9140, 9700, 9701, 9590-9980, no further editing is performed. The intent of this edit is to force review of in situ cases for which laterality is coded 4 (bilateral) or 9 (unknown laterality) as to origin. In rare instances when the tumor is truly midline (9) or the rare combination is otherwise confirmed correct, enter a code 1 for Override Site/Lat/Morph. Instructions for Coding Leave blank if the program does not generate an error message for the edit Laterality, Primary site, Morphology (SEER IF 42) and/or the edit Laterality, Primary site, Morph ICDO3 (SEER IF42). Leave blank and correct any errors for the case if an item is discovered to be incorrect. Code 1 if review of site, laterality and morphology verifies that the case had behavior code of "in situ" and laterality is not stated as "right: origin of primary;" "left: origin of primary;" or "only one side involved, right or left origin not specified"... NAACCR Data Standards and Data Dictionary Version 11
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- Site & laterality & morphology override flag
- Property
- Arb
- Time
- Pt
- System
- Cancer case.XXX
- Scale
- Ord
- Method
Additional Names
- Short Name
- Site/lat/morph O/R Cancer case
Normative Answer List: LL152-0
Answer | Code | Score | Answer ID |
---|---|---|---|
Reviewed | 1 | LA4354-2 | |
Not reviewed | Blank | LA4694-1 |
Basic Attributes
- Class
- TUMRRGT
- Type
- Clinical
- First Released
- Version 1.0m
- Last Updated
- Version 2.38
Member of these Panels
LOINC | Long Common Name |
---|---|
49083-9 | North American Association of Central Cancer Registries, Inc (NAACCR, Inc) version 11 panel |
59852-4 | North American Association of Central Cancer Registries, Inc (NAACCR, Inc) version 12 panel |
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
es-AR | Spanish (Argentina) | SITE&LATERALITY&MORPHOLOGY OVERRIDE FLAG: |
es-MX | Spanish (Mexico) | Indicador de anulación de sitio, lateralidad y morfología: |
it-IT | Italian (Italy) | Sito & lateralità & morfologia, flag ignorato: Synonyms: Arbitrario Caso di cancro XXX; |
ru-RU | Russian (Russian Federation) | Локализация & латеральность & морфология переопределение флаг: Synonyms: Латерализация Порядковый Произвольный Случай рака XXX Точка во времени; |
zh-CN | Chinese (China) | 部位与偏侧性与形态学重写标记: Synonyms: NAACCR 肿瘤登记; |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=22003-8
LOINC Copyright
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright