24342-8
Gas and Carbon monoxide panel - Capillary blood
Active
Term Description
Knowing the concentration of inspired O2 is important to the interpretation of PO2 results. Inspired O2 can be recorded in two ways- as percent- of O2 delivered to the patient (Venturi mask, re-breather mask, or ventilator) or as liters of oxygen per minute (nasal canula). This panel includes terms for recording the inspired O2 in either fashion. But because only one will apply and labs do not always receive this information they are designated as optional.
The term "oxygen saturation" is often used to refer to two distinctly different quantities, hemoglobin oxygen saturation (recommended symbol = sO2) and fractional oxyhemoglobin (recommended symbol = FO2Hb). The former is sometimes called functional oxygen saturation and the later, fractional oxygen saturation
Hemoglobin oxygen saturation = is the amount of oxyhemoglobin expressed as the percent of the hemoglobin able to bind oxygen, i.e. oxyhemoglobin (O2Hb) + deoxyhemoglobin (HHb).
sO2 = 100 x O2Hb/ (O2Hb + HHb)
Fractional oxyhemoglobin = the amount of oxyhemoglobin expressed as a percent of the total hemoglobin, where tHb = O2Hb + HHb + [COHb + MetHb + SulfHb]. Note that COHb, MetHb, and SulfHb, cannot carry oxygen and are thus called dyshemoglobins.
FO2Hb = O2Hb/tHb
Gas machines that can measure carbon monoxide, could, in principle, also report FO2Hb, and we had assumed that they would. However, at least some machines that do measure COHb and MetHb provide no option for reporting FO2Hb, and report only sO2. When mapping blood gas panels that report COHb% and also report FO2Hb, map that term to the LOINC term with the component of "Oxyhemoglobin /Total hemoglobin". If such an instrument reports only "oxygen saturation, verify with the lab that they are really reporting a functional O2 sat and not the Fractional Oxyhemoglobin, because the two are not always correctly labeled. If it is sO2 then map it to the LOINC term with a component of "Oxygen saturation".
When you are mapping data from a simpler Blood gas instrument (one that can read fewer than 4 wave lengths), then the O2 saturation will likely be a sO2. So map also moat that variable to the LOINC with a component of "Oxygen Saturation".
(Source: McD derived from Gill and McD- 2009 09)
Source: Regenstrief LOINC
Panel Hierarchy
Details for each LOINC in Panel LHC-Forms
LOINC | Name | R/O/C | Cardinality | Example UCUM Units |
---|---|---|---|---|
24342-8 | Gas and Carbon monoxide panel - Capillary blood | |||
Indent2745-8 | pH of Capillary blood | R | [pH] | |
Indent39485-8 | pH of Capillary blood adjusted to patient's actual temperature | O | [pH] | |
Indent2020-6 | Carbon dioxide [Partial pressure] in Capillary blood | R | mm[Hg] | |
Indent40620-7 | Carbon dioxide [Partial pressure] adjusted to patient's actual temperature in Capillary blood | O | mm[Hg] | |
Indent2704-5 | Oxygen [Partial pressure] in Capillary blood | R | mm[Hg] | |
Indent19256-7 | Oxygen [Partial pressure] adjusted to patient's actual temperature in Capillary blood | O | mm[Hg] | |
Indent19219-5 | Oxygen content in Capillary blood | O | mol/L | |
Indent1961-2 | Bicarbonate [Moles/volume] in Capillary blood | O | mmol/L | |
Indent16551-4 | Carbon dioxide, total [Moles/volume] in Capillary blood | C | mmol/L | |
Indent1926-5 | Base excess in Capillary blood by calculation | O | mmol/L | |
Indent1923-2 | Base deficit in Capillary blood | O | mmol/L | |
Indent2715-1 | Fractional oxyhemoglobin in Capillary blood | R | % | |
Indent2709-4 | Oxygen saturation in Capillary blood | C | % | |
Indent2031-3 | Carboxyhemoglobin/Hemoglobin.total in Capillary blood | R | % | |
Indent2616-1 | Methemoglobin/Hemoglobin.total in Capillary blood | R | % | |
Indent30352-9 | Hemoglobin [Mass/volume] in Capillary blood | O | g/dL | |
Indent3150-0 | Inhaled oxygen concentration | C | % | |
Indent3151-8 | Inhaled oxygen flow rate | C | L/min | |
Indent8310-5 | Body temperature | O | Cel |
Fully-Specified Name
- Component
- Gas & CO panel
- Property
- -
- Time
- Pt
- System
- BldC
- Scale
- Qn
- Method
Additional Names
- Short Name
- Gas + CO Pnl BldC
- Display Name
- Gas and Carbon monoxide panel (BldC)
- Consumer Name Alpha Get Info
- Gas and Carbon monoxide panel, Blood
Basic Attributes
- Class
- PANEL.CHEM
- Type
- Laboratory
- First Released
- Version 1.0o
- Last Updated
- Version 2.42
- Order vs. Observation
- Order
- Panel Type
- Panel
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
el-GR | Greek (Greece) | Έλεγχος αερίων και μονοξειδίου: |
es-AR | Spanish (Argentina) | pruebas analíticas de gases y monóxido de carbono: |
es-ES | Spanish (Spain) | Perfil gases y Co-oximetría: Synonyms: Cuantitativo |
es-MX | Spanish (Mexico) | Panel de gas y CO: |
fr-CA | French (Canada) | Gaz sanguins & Carboxyhémoglobine: |
fr-FR | French (France) | Gaz du sang et monoxyde de carbone panel: |
fr-BE | French (Belgium) | Gaz sanguins & Carboxyhémoglobine: Synonyms: Gaz sanguins & |
it-IT | Italian (Italy) | Gas & CO, panel: Synonyms: Chimica Panel gas & |
nl-NL | Dutch (Netherlands) | gassen & koolmonoxide panel: |
pl-PL | Polish (Poland) | Panel gazów i tlenku węgla: |
pt-BR | Portuguese (Brazil) | Gasometria painel: Synonyms: ; |
ru-RU | Russian (Russian Federation) | Газы & CO панель: Synonyms: Количественный Кровь капиллярная Точка во времени; |
tr-TR | Turkish (Turkey) | Gaz ve CO paneli: |
zh-CN | Chinese (China) | 气体与一氧化碳组套: Synonyms: 化学; |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=24342-8 - Questionnaire definition
- https:
//fhir.loinc.org/Questionnaire/?url=http: //loinc.org/q/24342-8
LOINC Copyright
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright