LOINC
Version 2.66

24887-2RFA Guidance for embolectomy of Pulmonary arteries-- W contrast IAActive

Component
Guidance for embolectomy^W contrast IA
Property
Find
Time
Pt
System
Chest>Pulmonary arteries
Scale
Doc
Method
RF.angio

Additional Names

Short Name
RFA Guided PA Embolec--W contr IA

Part Description

LP33542-9   Guidance for embolectomy
Surgical removal of an obstructing clot or foreign material which has been transported from a distant vessel by the bloodstream. Removal of a clot at its original site is called THROMBECTOMY. Source: National Library of Medicine, MeSH 2006

Basic Attributes

Class
RAD
Type
Clinical
First Released
Version 1.0o
Last Updated
Version 2.64
Change Reason
The scale has been changed from "Nar" to "Doc" to fit with the CDA model.; Jan 2016 Changed System from "Pulmonary artery" to "Chest>Pulmonary arteries" to clarify the System as including the main Pulmonary artery plus its branches and to conform with the LOINC/RadLex unified model; Method of "XR.fluor.angio" was changed to "RF.angio". The LOINC/RadLex Committee agreed to use a subset of the two-letter DICOM modality codes as the primary modality identifier.; Updated "Embolectomy^W contrast IA" in component based on LOINC/Radlex unified model
Order vs. Observation
Both
HL7 Attachment Structure
Implementation guide exists

Associated Observations

This panel contains the recommended sections for diagnostic imaging reports based on HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Releases 2.0 & 2.1.

LOINC Name R/O/C Cardinality Example UCUM Units
81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections
Indent11329-0 History general O
Indent55115-0 Request (Radiology) O
Indent55111-9 Current imaging procedure descriptions Document O
Indent55114-3 Prior procedure descriptions O
Indent18834-2 Radiology Comparison study - observation O
Indent18782-3 Radiology Study observation (findings) R
Indent19005-8 Radiology - Impression O
Indent18783-1 Radiology Study recommendation O
Indent55110-1 Conclusions O
Indent55107-7 Addendum O
Indent18785-6 Radiology Reason for study O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55112-7 Summary O
Indent55113-5 Key images O

Associated Observations

This panel contains the recommended sections for diagnostic imaging reports based on the HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Release 1.1.

LOINC Name R/O/C Cardinality Example UCUM Units
72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections
Indent18782-3 Radiology Study observation (findings) R
Indent55107-7 Addendum O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55110-1 Conclusions O
Indent55111-9 Current imaging procedure descriptions Document O
Indent11329-0 History general O
Indent55113-5 Key images O
Indent55114-3 Prior procedure descriptions O
Indent19005-8 Radiology - Impression O
Indent18834-2 Radiology Comparison study - observation O
Indent18785-6 Radiology Reason for study O
Indent18783-1 Radiology Study recommendation O
Indent55115-0 Request (Radiology) O
Indent55112-7 Summary O

Member of these Groups

LG41847-1 Region imaged: Chest

Language Variants Get Info

zh-CNChinese (China)
旨在栓子切除术的引导^采用动脉注射对比剂:发现:时间点:胸部>肺动脉类:文档型:放射荧光透视法.血管造影术
pt-BRPortuguese (Brazil)
Embolectomia^com contraste IA:Achado:Pt:Artéria Pulmonar:Nar:Radioscopia.angiografia
es-ARSpanish (Argentina)
embolectomía^con contraste.XXX intraarterial:hallazgo:punto en el tiempo:arteria pulmonar:Narrativo:fluoroangiografía

LOINC FHIR® API Example - CodeSystem Request Get Info

https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=24887-2