Part Description

LP21378-2   Catheter
In medicine, a catheter is a tube that can be inserted into a body cavity duct or vessel. Catheters thereby allow drainage or injection of fluids or access by surgical instruments. The process of inserting a catheter is catheterization. In most uses a catheter is a thin, flexible tube: a soft catheter; in some uses, it is a larger, solid tube: a hard catheter. Copyright Text is available under the Creative Commons Attribution/Share-Alike License. See http://creativecommons.org/licenses/by-sa/3.0/ for details. Source: Wikipedia, Catheter (Wikipedia)

LOINC Names Get Info

Fully-Specified Name
Guidance for placement of catheter for infusion of thrombolytic^W contrast intravascular:Find:Pt:XXX>Vessel:Doc:RF.angio
Long Common Name
RFA Guidance for placement of catheter for infusion of thrombolytic in Vessel-- W contrast intravascular
Short Name
RFA Guide Ves Cath throm adm W con vasc

Part Model Get Info

  • Component
    Guidance for placement of catheter for infusion of thrombolytic^W contrast intravascular
    LP309118-0
    • Analyte
      Guidance for placement of catheter for infusion of thrombolytic
      LP33515-5
      • Component Numerator
        Guidance for placement of catheter for infusion of thrombolytic
        LP33515-5
        • Component Numerator Core
          Guidance for placement of catheter for infusion of thrombolytic
          LP33515-5
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      W contrast intravascular
      LP173495-5
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Find
    LP6813-2
  • Time
    Pt
    LP6960-1
  • System
    XXX>Vessel
    LP220309-1
  • Scale
    Doc
    LP32888-7
  • Method
    RF.angio
    LP220469-3

Associated Observations

81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Releases 2.0 & 2.1.

LOINCNameR/O/CCardinalityExample UCUM Units
81220-6Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections
Indent11329-0History generalO
Indent55115-0Request (Radiology)O
Indent55111-9Current imaging procedure descriptions DocumentO
Indent55114-3Prior procedure descriptionsO
Indent18834-2Radiology Comparison study - observationO
Indent18782-3Radiology Study observation (findings)R
Indent19005-8Radiology - ImpressionO
Indent18783-1Radiology Study recommendationO
Indent55110-1ConclusionsO
Indent55107-7AddendumO
Indent18785-6Radiology Reason for studyO
Indent55108-5Patient presentationO
Indent55109-3ComplicationsO
Indent55112-7SummaryO
Indent55113-5Key imagesO

72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on the HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Release 1.1.

LOINCNameR/O/CCardinalityExample UCUM Units
72230-6Diagnostic imaging report - recommended C-CDA R1.1 sections
Indent18782-3Radiology Study observation (findings)R
Indent55107-7AddendumO
Indent55108-5Patient presentationO
Indent55109-3ComplicationsO
Indent55110-1ConclusionsO
Indent55111-9Current imaging procedure descriptions DocumentO
Indent11329-0History generalO
Indent55113-5Key imagesO
Indent55114-3Prior procedure descriptionsO
Indent19005-8Radiology - ImpressionO
Indent18834-2Radiology Comparison study - observationO
Indent18785-6Radiology Reason for studyO
Indent18783-1Radiology Study recommendationO
Indent55115-0Request (Radiology)O
Indent55112-7SummaryO

Basic Attributes

Class
RAD
Type
Clinical
First Released
Version 1.0o
Last Updated
Version 2.64 (NAM)
Change Reason
The scale has been changed from "Nar" to "Doc" to fit with the CDA model. Changed system from Vessel for conformance with LOINC/RadLex unified model.; Method of "XR.fluor.angio" was changed to "RF.angio". The LOINC/RadLex Committee agreed to use a subset of the two-letter DICOM modality codes as the primary modality identifier.; Fixed spelling of "adminstration"; Updated "administration" to "infusion" for consistency across terms
Order vs. Observation
Both
HL7® Attachment Structure
Implementation guide exists

Member of these Groups Get Info

LOINC GroupGroup Name
LG41853-9Region imaged: Unspecified (XXX)

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Οδηγίες για τοποθέτηση καθετήρα για έγχυση θρομβολυτικού^Με σκιαγραφικό ενδοαγγειακά:Εύρεση:Pt:XXX>Αγγείο:Doc:RF.angio
Synonyms: Doc Pt RAD RF RF.angio XXX XXX>Αγγείο Ενδοαγγειακός Εύρεση Με σκιαγραφικό Με σκιαγραφικό ενδοαγγειακά Οδηγίες Οδηγίες για τοποθέτηση καθετήρα Οδηγίες για τοποθέτηση καθετήρα για έγχυση θρομβολυτικού
es-ARSpanish (Argentina)guía para procedimiento de colocación de catéter para la administración de agente trombolítico^con contraste.XXX intravascular:hallazgo:punto en el tiempo:vaso.XXX:Narrativo:fluoroangiografía
es-MXSpanish (Mexico)Guía para la colocación del catéter para infusión de contraste trombolítico ^ W intravascular:Tipo:Punto temporal:XXX> Buque:Documento:RF.angio
it-ITItalian (Italy)Linee guida per posizionamento di catetere per somministrazione di trombolitico^Con contrasto intravascolare:Osservazione:Pt:XXX>Vaso:Doc:RF.angio
Synonyms: Osservazione Punto nel tempo (episodio) Raccomandazioni cliniche per posizionamento di catetere Raccomandazioni cliniche per posizionamento di catetere per somministrazione di trombolitico Radio-fluoroscopia Radio-fluoroscopia Angiografia Radiologia Vaso
pt-BRPortuguese (Brazil)Orientação para colocação de catéter para administração de trombolítico^com contraste intravascular:Achado:Pt:Vaso.XXX:Nar:Radioscopia.angiografia
Synonyms: ; Plac of cath; Cath plac guid for TL admin; W contr; WC; Finding; Findings; Point in time; Random; ves; Misc; Miscellaneous; Unspecified; Other; Narrative; Report; XRA; Angiogram; Ang; Angm; Flr; Fluoro; Fluoroscopy; Xray; X-ray; Plain Films; Thrombolysis; IV; Intravenous; Guid; Guided; Guide; c; Contrst; Contr; Contra; RADIOLOGY; Imaging
zh-CNChinese (China)旨在为输注溶栓剂而置入导管的引导^采用血管内对比剂:发现:时间点:XXX>血管:文档型:放射荧光透视法.血管造影术
Synonyms: RF;放射荧光透视;放射线荧光透视法;放射线荧光透视;透视摄影;无线荧光透视法;无线荧光透视 XXX>血管(脉管) 不明的;其他;将在相应消息内其他部分之中加以详细说明;未作详细说明的;未作说明的;未做说明的标本;未加规定的;未加说明的标本;杂项 临床文档型;临床文档;文档;文书;医疗文书;临床医疗文书 制导 发现是一个原子型临床观察指标,并不是作为印象的概括陈述。体格检查、病史、系统检查及其他此类观察指标的属性均为发现。它们的标尺对于编码型发现可能是名义型,而对于叙述型文本之中所报告的发现,则可能是叙述型。;发现物;所见;结果;结论 增强剂 对比增强剂 导向 导尿管 导管 导管置入 成像;放射医学;放射学;显像 指导 指引 放射荧光透视法(RF、放射荧光透视、放射线荧光透视法、放射线荧光透视、透视摄影、无线荧光透视法、无线荧光透视).血管造影术(血管造影、血管照相术、血管照相、血管学、血管摄影、血管摄影术) 旨在(针对、用于)为输注(输入、施用、使用、给予)溶栓剂(血栓溶解剂、溶解血栓剂、溶血栓药、溶栓药物、溶血栓药物)而置入(安置、放置、摆位、安排)导管(导液管)的引导;旨在为施用溶栓剂而进行导管置入(置入术)的引导 旨在(针对、用于)置入(安置、放置、摆位、安排)导管(导液管)的引导;旨在导管置入(置入术)的引导 时刻;随机;随意;瞬间 溶栓 溶栓剂 溶血栓 溶解血栓 溶解血栓的 置入导管 脉管 血栓溶解 血栓溶解剂 血管内的 采用增强剂;采用对比增强剂 采用血管内增强剂

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=25028-2