Version 2.78

Part Description

LP6617-7   US.doppler
Doppler ultrasound detects the shift in frequency of ultrasound signals reflected from moving objects. Conventional Doppler techniques assess the velocity of blood flow by measuring high-frequency, low-amplitude signals from small, fast-moving blood cells. PMID: 16534017 Source: Regenstrief LOINC, PMID: 16534017

Fully-Specified Name

Component
Multisection for graft
Property
Find
Time
Pt
System
Upper extremity>Upper extremity vessel
Scale
Doc
Method
US.doppler

Additional Names

Short Name
DOP UE ves for graft

Associated Observations

81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Releases 2.0 & 2.1.

LOINC Name R/O/C Cardinality Example UCUM Units
81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections
Indent11329-0 History general O
Indent55115-0 Request (Radiology) O
Indent55111-9 Current imaging procedure descriptions Document O
Indent55114-3 Prior procedure descriptions O
Indent18834-2 Radiology Comparison study - observation O
Indent18782-3 Radiology Study observation (findings) R
Indent19005-8 Radiology - Impression O
Indent18783-1 Radiology Study recommendation O
Indent55110-1 Conclusions O
Indent55107-7 Addendum O
Indent18785-6 Radiology Reason for study O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55112-7 Summary O
Indent55113-5 Key images O

72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on the HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Release 1.1.

LOINC Name R/O/C Cardinality Example UCUM Units
72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections
Indent18782-3 Radiology Study observation (findings) R
Indent55107-7 Addendum O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55110-1 Conclusions O
Indent55111-9 Current imaging procedure descriptions Document O
Indent11329-0 History general O
Indent55113-5 Key images O
Indent55114-3 Prior procedure descriptions O
Indent19005-8 Radiology - Impression O
Indent18834-2 Radiology Comparison study - observation O
Indent18785-6 Radiology Reason for study O
Indent18783-1 Radiology Study recommendation O
Indent55115-0 Request (Radiology) O
Indent55112-7 Summary O

Basic Attributes

Class
RAD
Type
Clinical
First Released
Version 2.19
Last Updated
Version 2.61
Change Reason
The scale has been changed from "Nar" to "Doc" to fit with the CDA model. Moved "graft" from the System to Component to represent the Reason for Exam and changed System from "Upper extremity vessel graft" to "Upper extremity>Upper extremity vessel" for conformance with the LOINC/Radlex unified model.
Order vs. Observation
Both
HL7® Attachment Structure
Implementation guide exists

Member of these Groups Get Info

LOINC Group Group Name
LG41850-5 Region imaged: Upper extremity
LG38360-0 US.doppler|Upper extremity vessel|Multisection for graft|Laterality:ANY

Language Variants Get Info

Tag Language Translation
es-MX Spanish (Mexico) Multisección para injerto:Tipo:Punto temporal:Extremidad superior> Vaso de la extremidad superior:Documento:US.doppler
it-IT Italian (Italy) Sezioni multiple per innesto:Osservazione:Pt:Estremità superiore>Vaso di estremità superiore:Doc:Eco.doppler
Synonyms: Eco Ecografia.doppler Multistrato Multistrato per trapianto Osservazione Punto nel tempo (episodio) Radiologia Vaso delle estremità Vaso dell''estremità superiore
pt-BR Portuguese (Brazil) Seccionais:Achado:Pt:Enxerto vaso do membro superior:Nar:US.Doppler
Synonyms: Finding; Findings; Point in time; Random; UE ves graft; Arm; Extr ves; EXT; Narrative; Report; DOP; DUPLEX; Ultrasound; ULS; Sonogram; Sonography; Sonograph; Echography; RADIOLOGY; Imaging
zh-CN Chinese (China) 针对移植物的多层:发现:时间点:上肢>上肢血管:文档型:超声.多普勒
Synonyms: (多层(多平面、多切面、多断面、多截面、多剖面、多排) Up 上的 上肢(胳膊、手臂、臂);胳膊;手臂;臂) 上肢(胳膊、手臂、臂)>上肢(胳膊、手臂、臂)血管;上肢(胳膊、手臂、臂)血管(脉管) 上边 上边的 上部 上部的 上部的(Upper,Up) 上面 上面的 临床文档型;临床文档;文档;文书;医疗文书;临床医疗文书 发现是一个原子型临床观察指标,并不是作为印象的概括陈述。体格检查、病史、系统检查及其他此类观察指标的属性均为发现。它们的标尺对于编码型发现可能是名义型,而对于叙述型文本之中所报告的发现,则可能是叙述型。;发现物;所见;结果;结论 在上面 在上面的 多层(多平面、多切面、多断面、多截面、多剖面、多排);多排 心脏超声.多普勒 成像;放射医学;放射学;显像 时刻;随机;随意;瞬间 肢;四肢 肢体(肢、四肢)血管(脉管);四肢脉管;肢体脉管;肢体血管 脉管 超声检查方法;超声检查法;超声波;超声波检查方法;超声波检查法 较高 较高的 针对(旨在、用于)移植物(移植体)的多层(多平面、多切面、多断面、多截面、多剖面、多排)

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=46385-1