52776-2
Clotting time.intrinsic coagulation system activated of Blood by Rotational TEG
Active
Term Description
CT (Clotting time): The CT is the latency time from adding the start reagent to blood until the clot starts to form. Prolongation of CT may be a result of coagulation deficiencies, primarily coagulation factors, or heparin (dependent on the test used). A potential contribution of heparin can be detected by comparing INTEM- with HEPTEM CT data (see "reagents" below). A shortening of CT indicates hypercoagulability.
Source: Wikipedia
Part Description
LP270303-3 Thromboelastography.rotational
Rotational thromboelastography, also called thromboelastometry or ROTEM, is similar to traditional thromboelastography (TEG) in that it is used to measure the viscoelastic properties of a clot. In TEG, whole blood is added to a cup in which a pin is suspended, the cup is rotated, and as the clot forms, the rotational force is transferred to the pin. The movement of the pin is transformed into a tracing, from which the clotting parameters are derived. In ROTEM, the cup is stationary and the pin rotates, and as the clot forms, the rotation of the pin slows down. The torsion of the pin is transformed into a tracing from which the ROTEM parameters are derived. PMID: 22726088
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- Clotting time.intrinsic coagulation system activated
- Property
- Time
- Time
- Pt
- System
- Bld
- Scale
- Qn
- Method
- Thromboelastography.rotational
Additional Names
- Long Common Name
- Clotting time.intrinsic coagulation system activated of Blood by Rotational TEG
- Short Name
- CT.intrinsic Bld ROTEM
- Display Name
- Clotting time.intrinsic coagulation system activated ROTEM (Bld)
- Consumer Name Alpha Get Info
- Clotting time.intrinsic coagulation system activated, Blood
Basic Attributes
- Class
- COAG
- Type
- Laboratory
- First Released
- Version 2.24
- Last Updated
- Version 2.73 (MIN)
- Change Reason
- Updated Method from Thromboelastography to clarify that the Method used for this assay is rotational TEG ("ROTEM") and to distinguish from the original thromboelastography and new resonance thromboelastography Methods.
- Order vs. Observation
- Observation
- Common Test Rank Get Info
- 1973
Member of these Panels
LOINC | Long Common Name |
---|---|
52762-2 | Intrinsic coagulation system thromboelastography panel - Blood |
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
de-AT | German (Austria) | Synonyms: Clotting Time INTEM |
de-DE | German (Germany) | Gerinnungszeit.intrinsisches Gerinnungssystem aktiviert: Synonyms: Thromboelastographie |
el-GR | Greek (Greece) | Χρόνος σχηματισμού θρόμβου.ενεργοποιημένο ενδογενές σύστημα πήξης: Synonyms: Time Πήξη Χρόνος πήξης Χρόνος σχηματισμού θρόμβου.ενεργοποιημένο ενδογενές σύστημα πήξης |
es-ES | Spanish (Spain) | Activación del sistema intrinseco de coagulación. Tiempo de coagulación: Synonyms: Cuantitativo |
es-MX | Spanish (Mexico) | Tiempo de coagulación Sistema de coagulación intrínseco activado: |
fr-FR | French (France) | Temps de coagulation (activation de la voie intrinsèque): |
it-IT | Italian (Italy) | Tempo di coagulazione.sistema coagulazione intrinseco attivato: Synonyms: Punto nel tempo (episodio) Sangue Studio di coagulazione TEG Tempo (e.g. secondi) Tromboelastografia rotazionale; |
pl-PL | Polish (Poland) | Czas krzepnięcia.szlak wewnątrzpochodny aktywowany: Synonyms: Czas krzepnięcia po aktywacji szlaku wewnątrzpochodnego |
pt-BR | Portuguese (Brazil) | Tempo de Coagulação.sistema de coagulação intrínseca ativado: Synonyms: ; |
zh-CN | Chinese (China) | 凝血时间.内源性凝血系统激活型: Synonyms: 凝固 凝固; |
Example Units
Unit | Source |
---|---|
s | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=52776-2
LOINC Copyright
Copyright © 2025 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://