52788-7
Maximum lysis.intrinsic coagulation system activated.heparin insensitive [Length fraction] in Blood by Rotational TEG
Active
Term Description
The ML (Maximum Lysis) parameter describes the percentage of lost clot stability (relative to MCF, in %) viewed at any selected time point or when the test has been stopped. A high ML value indicates hyperfibrinolysis. While in normal blood fibrinolysis activity is quite low, in clinical samples a more rapid loss of clot stability by hyperfibrinolysis may lead to bleeding complications which can be treated by the administration of antifibrinolytic drugs.
Source: Wikipedia
Part Description
LP270303-3 Thromboelastography.rotational
Rotational thromboelastography, also called thromboelastometry or ROTEM, is similar to traditional thromboelastography (TEG) in that it is used to measure the viscoelastic properties of a clot. In TEG, whole blood is added to a cup in which a pin is suspended, the cup is rotated, and as the clot forms, the rotational force is transferred to the pin. The movement of the pin is transformed into a tracing, from which the clotting parameters are derived. In ROTEM, the cup is stationary and the pin rotates, and as the clot forms, the rotation of the pin slows down. The torsion of the pin is transformed into a tracing from which the ROTEM parameters are derived. PMID: 22726088
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- Maximum lysis.intrinsic coagulation system activated.heparin insensitive
- Property
- LenFr
- Time
- Pt
- System
- Bld
- Scale
- Qn
- Method
- Thromboelastography.rotational
Additional Names
- Long Common Name
- Maximum lysis.intrinsic coagulation system activated.heparin insensitive [Length fraction] in Blood by Rotational TEG
- Short Name
- ML.heparin insens LenFr Bld ROTEM
- Display Name
- Maximum lysis.intrinsic coagulation system activated.heparin insensitive ROTEM (Bld) [Length fraction]
- Consumer Name Alpha Get Info
- Maximum lysis.intrinsic coagulation system activated.heparin insensitive, Blood
Basic Attributes
- Class
- COAG
- Type
- Laboratory
- First Released
- Version 2.24
- Last Updated
- Version 2.70 (MIN)
- Change Reason
- Updated Method from Thromboelastography to clarify that the Method used for this assay is rotational TEG ("ROTEM") and to distinguish from the original thromboelastography and new resonance thromboelastography Methods.
- Order vs. Observation
- Observation
Member of these Panels
LOINC | Long Common Name |
---|---|
52777-0 | Intrinsic coagulation system with heparin inhibition thromboelastography panel - Blood |
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
el-GR | Greek (Greece) | Μέγιστη λύση.ενεργοποιημένο ενδογενές σύστημα πήξης.μη ευαίσθητο στην ηπαρίνη: Synonyms: LenFr Ηπαρίνη Μέγιστη λύση Μέγιστη λύση.ενεργοποιημένο ενδογενές σύστημα πήξης Μέγιστη λύση.ενεργοποιημένο ενδογενές σύστημα πήξης.μη ευαίσθητο στην ηπαρίνη Πήξη |
es-ES | Spanish (Spain) | Lisis máxima. sistema intrínseco de coagulación activado.resistente a heparina: Synonyms: Cuantitativo |
es-MX | Spanish (Mexico) | Lisis máxima, sistema de coagulación intrínseco activado, insensible a la heparina: |
fr-FR | French (France) | Lyse maximale (activation voie intrinsèque) héparine insensible: |
it-IT | Italian (Italy) | Lisi massima.sistema intrinseco di coagulazione attivato.eparina insensibile: Synonyms: Frazione di lunghezza Punto nel tempo (episodio) Sangue Studio di coagulazione TEG Tromboelastografia rotazionale; |
pl-PL | Polish (Poland) | Maksymalna liza.szlak wewnątrzpochodny aktywowany.niewrażliwa na heparynę: Synonyms: Maksymalna liza po aktywacji szlaku wewnątrzpochodnego Maksymalna liza po aktywacji szlaku wewnątrzpochodnego niewrażliwa na heparynę |
pt-BR | Portuguese (Brazil) | Lise máxima.sistema de coagulação intrínseca ativado.insensível a heparina: Synonyms: ; |
zh-CN | Chinese (China) | 最大溶解.内源性凝血系统激活型.肝素不敏感型: Synonyms: 凝固; |
Example Units
Unit | Source |
---|---|
% | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=52788-7
LOINC Copyright
Copyright © 2025 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://