From the Puritan Bennett 840 Operator's and Technical Reference Manual: The DSENS setting defines the percentage of returned volume lost, above which the ventilator declares a CIRCUIT DISCONNECT alarm. When DSENS is set to its lowest value (20%), it has the highest sensitivity for detecting a disconnect or leak. When DSENS is set to its highest value (95%), the ventilator has the least sensitivity for detecting a circuit disconnection, as greater than 95% of the returned volume must be lost before the alarm occurs.

LOINC Names Get Info

Fully-Specified Name
Disconnect sensitivity setting:VFr:Pt:Ventilator.alarm:Qn:
Long Common Name
Disconnect sensitivity setting Ventilator alarm
Short Name
Disconnect sensitivity VFr Vent alarm

Part Model Get Info

  • Component
    Disconnect sensitivity setting
    LP97532-3
    • Analyte
      Disconnect sensitivity setting
      LP97532-3
      • Component Numerator
        Disconnect sensitivity setting
        LP97532-3
        • Component Numerator Core
          Disconnect sensitivity setting
          LP97532-3
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    VFr
    LP6891-8
  • Time
    Pt
    LP6960-1
  • System
    Ventilator.alarm
    LP7709-1
    • System Core
      Ventilator.alarm
      LP7709-1
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    NULL
     

Basic Attributes

Class
PULM
Type
Clinical
First Released
Version 2.29
Last Updated
Version 2.70 (MIN)
Order vs. Observation
Observation

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Αποσύνδεση ρύθμιση ευαισθησίας:VFr:Pt:Αναπνευστήρας.συναγερμός:Qn:
Synonyms: Pt PULM Qn VFr Αναπνευστήρας Αναπνευστήρας.συναγερμός Αποσύνδεση ρύθμιση ευαισθησίας Πλαίσιο
es-MXSpanish (Mexico)Desconectar el ajuste de sensibilidad:VFr:Punto temporal:Ventilador.alarma:Cuantitativo:
it-ITItalian (Italy)Sensibilità disconnessione, setting:VFr:Pt:Respiratore.allarme:Qn:
Synonyms: Allarme del respiratore Frazione di Volume Gestione ventilazione polmonare Impostazione sensibilità di disconnessione Punto nel tempo (episodio) Setting sensibilità di disconnessione
pt-BRPortuguese (Brazil)Desligue o ajuste de sensibilidade:#N/A:Pt:Ventilador.alarme:Qn:
Synonyms: ; Fr; Volume fraction; Volfr; Percent; Point in time; Random; Vent alarm; Quantitative; QNT; Quant; Quan; PULMONARY
ru-RURussian (Russian Federation)Отсоединение чувствительность установка:ОбФр:ТчкВрм:Аппарат ИВЛ.сигнал тревоги:Колич:
Synonyms: Аппарат искусственной вентиляции лёгких Количественный Объемная фракция Точка во времени;Момент
zh-CNChinese (China)断开灵敏度设置:体积分数:时间点:呼吸机.警报:定量型:
Synonyms: 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 呼吸机(通气装置、呼吸器).警报(警告、报警、警示) 容积分数 断开连接灵敏度设置;管道脱落灵敏度设置;脱落灵敏度设置;脱管灵敏度设置 时刻;随机;随意;瞬间 肺部测量指标与呼吸机管理 设置;环境;场景;背景;设置;设定 通气装置;呼吸器

Example Units

UnitSource
%Example UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=57657-9