Disconnect sensitivity setting Ventilator alarm
Active
Term Description
From the Puritan Bennett 840 Operator's and Technical Reference Manual: The DSENS setting defines the percentage of returned volume lost, above which the ventilator declares a CIRCUIT DISCONNECT alarm. When DSENS is set to its lowest value (20%), it has the highest sensitivity for detecting a disconnect or leak. When DSENS is set to its highest value (95%), the ventilator has the least sensitivity for detecting a circuit disconnection, as greater than 95% of the returned volume must be lost before the alarm occurs.
LOINC Names Get Info
- Fully-Specified Name
- Disconnect sensitivity setting:
VFr: Pt: Ventilator.alarm: Qn: - Long Common Name
- Disconnect sensitivity setting Ventilator alarm
- Short Name
- Disconnect sensitivity VFr Vent alarm
Part Model Get Info
- Component
- Disconnect sensitivity setting
LP97532-3
- Analyte
- Disconnect sensitivity setting
LP97532-3
- Challenge
- NULL
- Adjustment
- NULL
- Count
- NULL
- Property
- VFr
LP6891-8
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- Ventilator.alarm
LP7709-1
- System Core
- Ventilator.alarm
LP7709-1
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- NULL
Basic Attributes
- Class
- PULM
- Type
- Clinical
- First Released
- Version 2.29
- Last Updated
- Version 2.70 (MIN)
- Order vs. Observation
- Observation
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Αποσύνδεση ρύθμιση ευαισθησίας: Synonyms: Pt PULM Qn VFr Αναπνευστήρας Αναπνευστήρας.συναγερμός Αποσύνδεση ρύθμιση ευαισθησίας Πλαίσιο |
| es-MX | Spanish (Mexico) | Desconectar el ajuste de sensibilidad: |
| it-IT | Italian (Italy) | Sensibilità disconnessione, setting: Synonyms: Allarme del respiratore Frazione di Volume Gestione ventilazione polmonare Impostazione sensibilità di disconnessione Punto nel tempo (episodio) Setting sensibilità di disconnessione |
| pt-BR | Portuguese (Brazil) | Desligue o ajuste de sensibilidade: Synonyms: ; |
| ru-RU | Russian (Russian Federation) | Отсоединение чувствительность установка: Synonyms: Аппарат искусственной вентиляции лёгких Количественный Объемная фракция Точка во времени; |
| zh-CN | Chinese (China) | 断开灵敏度设置: Synonyms: 可用数量表示的; |
Example Units
| Unit | Source |
|---|---|
| % | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://