62615-0
PhenX - respiratory - bronchodilator responsiveness - BDR protocol 090301
Active
Term Description
A series of spirometry maneuvers is performed to obtain acceptable and reproducible results. An inhaled bronchodilator medication is administered, and a second series of spirometry maneuvers is performed. The Spirometry measure, also found in the Toolkit, should be followed for step 1 of the BDR testing process.
Reference Information
| Type | Source | Reference |
|---|---|---|
| Citation | Consensus measures for Phenotypes and Exposures | US Department of Health and Human Services, National Institutes of Health, COPDGene Study, Manual of Procedures, Version 5.0 June 15, 2009. Refer to Clinical Center Manual of Procedures. |
Panel Hierarchy
Details for each LOINC in Panel LHC-Forms
| LOINC | Name | R/O/C | Cardinality | Example UCUM Units |
|---|---|---|---|---|
| 62615-0 | PhenX - respiratory - bronchodilator responsiveness - BDR protocol 090301 | |||
| Indent8867-4 | Heart rate | R | {beats}/min;{counts}/min | |
| Indent64024-3 | Spirometry Contraindicated | |||
| Indent64025-0 | Reason for Contraindication | |||
| Indent64026-8 | Pre-bronchodilator forced expiratory volume, FEV, in 1 second attempt | |||
| Indent20157-4 | FEV1 --pre bronchodilation | L | ||
| Indent64027-6 | Pre-Bronchodilator Forced Vital Capacity (FVC) attempt | |||
| Indent19876-2 | Forced vital capacity [Volume] Respiratory system by Spirometry --pre bronchodilation | L | ||
| Indent64028-4 | Post-Bronchodilator Forced Expiratory Volume (FEV1) in 1 second attempt | |||
| Indent20155-8 | FEV1 --post bronchodilation | L | ||
| Indent64029-2 | Post-Bronchodilator Forced Vital Capacity (FVC) attempt | |||
| Indent19874-7 | Forced vital capacity [Volume] Respiratory system by Spirometry --post bronchodilation | L | ||
| Indent64030-0 | Percent of Baseline Forced Expiratory Volume in 1 second | %{baseline} | ||
| Indent20152-5 | FEV1 measured/predicted | % | ||
| Indent64031-8 | Absolute Volume | L |
LOINC Names Get Info
- Fully-Specified Name
- PhenX - respiratory - bronchodilator responsiveness - BDR protocol 090301:
-: Pt: ^Patient: -: PhenX - Long Common Name
- PhenX - respiratory - bronchodilator responsiveness - BDR protocol 090301
- Short Name
- Resp bronchodil respons proto
Part Model Get Info
- Component
- PhenX - respiratory - bronchodilator responsiveness - BDR protocol 090301
LP111959-5
- Analyte
- PhenX - respiratory - bronchodilator responsiveness - BDR protocol 090301
LP111959-5
- Component Numerator
- PhenX - respiratory - bronchodilator responsiveness - BDR protocol 090301
LP111959-5
- Component Numerator Core
- PhenX - respiratory - bronchodilator responsiveness - BDR protocol 090301
LP111959-5
- Component Numerator Core Suffix
- NULL
- Component Denominator
- NULL
- Component Denominator Core
- NULL
- Component Denominator Core Suffix
- NULL
- Challenge
- NULL
- Adjustment
- NULL
- Count
- NULL
- Property
- -
LP6769-6
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- ^Patient
LP310005-6
- System Core
- NULL
- Super System
- Patient
LP6985-8
- Scale
- -
LP7747-1
- Method
- PhenX
LP95333-8
Survey Question
- PX090301
Basic Attributes
- Class
- PANEL.PHENX
- Type
- Clinical
- First Released
- Version 2.36
- Last Updated
- Version 2.81 (MIN)
- Change Reason
- Release 2.81: Status: Changing PhenX Concept from Status = Trial to Active; Previous Releases: Updated the PhenX ID from "PhenX.<ID>" to "PX<ID>" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.
- Panel Type
- Panel
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 62611-9 | PhenX domain - Respiratory |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | PhenX - αναπνευστικό - άβρογχοδιασταλτική ανταπόκριση - BDR πρωτόκολλο 090301: Synonyms: - PANEL.PHENX PHENX PhenX - αναπνευστικό - άβρογχοδιασταλτική ανταπόκριση - BDR πρωτόκολλο 090301 Pt Ασθενής |
| es-MX | Spanish (Mexico) | PhenX - respiratorio - respuesta broncodilatadora - protocolo BDR 090301: |
| it-IT | Italian (Italy) | PhenX - respiratorio - risposta al broncodilatatore - BDR, protocollo: Synonyms: Panel PhenX paziente PhenX Punto nel tempo (episodio) |
| ru-RU | Russian (Russian Federation) | PhenX - дыхание - бронходилататор ответ - BDR протокол: Synonyms: Точка во времени; |
| zh-CN | Chinese (China) | PhenX - 呼吸系统 - 支气管扩张剂响应性方案 090301: Synonyms: Consensus measures for Phenotypes and eXposures; |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=62615-0 - Questionnaire definition
- https:
//fhir.loinc.org/Questionnaire/?url=http: //loinc.org/q/62615-0
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://