Status Information

Status
DISCOURAGED

Term Description

The Six-Minute Walk Test is a timed test that requires minimal technical resources to measure the distance that a patient can quickly walk on a flat, hard surface in a period of 6 minutes (the six-minute walk distance, 6MWD). This measure has been shown to be a reproducible, objective indicator of functional capacity and is a part of the multicomponent BODE index (body-mass index, airflow obstruction, dyspnea, and exercise capacity) that correlates with survival. It is important to emphasize that this is a test of maximum exercise performance; subjects should be instructed and encouraged to push themselves to achieve maximal distance.

Reference Information

TypeSourceReference
CitationConsensus measures for Phenotypes and ExposuresAmerican Thoracic Society. (2002). ATS Statement: Guidelines for the six-minute walk test. American Journal of Respiratory and Critical Care Medicine, 166(1), 111-117.
ArticleConsensus measures for Phenotypes and ExposuresEisner, MD, Iribarren, C, Yelin, EH, Sidney, S, Katz, PP, Ackerson, L, Lathon, P, Tolstykh, I, Omachi, T, Byl, N, Blanc, PD. (2008). Pulmonary function and the risk of functional limitation in chronic obstructive pulmonary disease. American Journal of Epidemiology, 167, 1090-1101.
ArticleConsensus measures for Phenotypes and ExposuresEnright, PL. (2003). The Six-minute walk test. Respiratory Care, 48, 783-785.
ArticleConsensus measures for Phenotypes and ExposuresMascolo, MC, Truwit, JD. (2003). Role of exercise evaluation in restrictive lung disease: new insights between March 2001 and February 2003. Current Opinion in Pulmonary Medicine, 9, 408-410
ArticleConsensus measures for Phenotypes and ExposuresNixon PA, Joswiak ML, Fricker FJ. A six-minute walk test for assessing exercise tolerance in severely ill children. J Pediatr 1996; 129:362-366.

Panel Hierarchy

Details for each LOINC in Panel LHC-Forms

LOINCNameR/O/CCardinalityExample UCUM Units
62619-2PhenX - respiratory - exercise capacity - 6 minute walk test protocol 090601
Indent64100-1Contraindication
Indent64107-6Number of laps{#}
Indent8480-6Systolic blood pressureRmm[Hg]
Indent8462-4Diastolic blood pressureRmm[Hg]
Indent45847-1Oxygen therapy [Minimum Data Set]
Indent3151-8Inhaled oxygen flow rateCL/min
Indent64102-7Supplemental oxygen during the test type
Indent64103-5Baseline Time{clock_time}
Indent40443-4Heart rate --resting{beats}/min
Indent64113-4Baseline Dyspnea (from the Borg scale)
Indent64101-9Baseline Fatigue (from the Borg scale)
Indent59417-6Oxygen saturation in Arterial blood by Pulse oximetry --resting%
Indent64114-2End of test time{clock_time}
Indent40442-6Heart rate --post exercise{beats}/min
Indent64112-6End of Test Dyspnea (from Borg scale)
Indent64097-9End of Test Fatigue (from Borg scale)
Indent59412-7Oxygen saturation in Arterial blood by Pulse oximetry --post exercise%
Indent64104-3Stopped or paused before 6 minutes?
Indent64105-0Reason stopped or paused before 6 minutes
Indent64106-8Other symptoms at end of exercise
Indent64107-6Number of laps{#}
Indent64108-4Final partial lap distancem
Indent64098-7Total distance walked in 6 minutes (Number of laps X 60 meters + Final partial lap distance)m/(6.min)
Indent8251-1Service comment
Indent64110-0Interpretation (including comparison with a preintervention 6MWD)

LOINC Names Get Info

Fully-Specified Name
PhenX - respiratory - exercise capacity - 6M walk test protocol 090601:-:Pt:^Patient:-:PhenX
Long Common Name
PhenX - respiratory - exercise capacity - 6 minute walk test protocol 090601
Short Name
Resp exercise 6M walk proto

Part Model Get Info

  • Component
    PhenX - respiratory - exercise capacity - 6M walk test protocol 090601
    LP111963-7
    • Analyte
      PhenX - respiratory - exercise capacity - 6M walk test protocol 090601
      LP111963-7
      • Component Numerator
        PhenX - respiratory - exercise capacity - 6M walk test protocol 090601
        LP111963-7
        • Component Numerator Core
          PhenX - respiratory - exercise capacity - 6M walk test protocol 090601
          LP111963-7
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    -
    LP6769-6
  • Time
    Pt
    LP6960-1
  • System
    ^Patient
    LP310005-6
    • System Core
      NULL
       
    • Super System
      Patient
      LP6985-8
  • Scale
    -
    LP7747-1
  • Method
    PhenX
    LP95333-8

Survey Question

PX090601

Basic Attributes

Class
PANEL.PHENX
Type
Clinical
First Released
Version 2.36
Last Updated
Version 2.81 (MIN)
Change Reason
Release 2.81: Status: Changing concept status from Trial to Discouraged upon recommendation from RTI; concept is deprecated in PhenX toolkit; Previous Releases: Updated the PhenX ID from "PhenX.<ID>" to "PX<ID>" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.
Panel Type
Panel

Member of these Panels

LOINCLong Common Name
62611-9PhenX domain - Respiratory

Member of these Groups Get Info

LOINC GroupGroup Name
LG41761-4Exercise/Activity

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)PhenX - αναπνευστικό - ικανότητα άσκησης - δοκιμασία βάδισης 6 λεπτών πρωτόκολλο 090601:-:Pt:^Ασθενής:-:PhenX
Synonyms: - PANEL.PHENX PHENX PhenX - αναπνευστικό - ικανότητα άσκησης - δοκιμασία βάδισης 6 λεπτών πρωτόκολλο 090601 Pt Ασθενής
es-MXSpanish (Mexico)PhenX - respiratorio - capacidad de ejercicio - protocolo de prueba de marcha 6M 090601:-:Punto temporal:^ Paciente:-:PhenX
it-ITItalian (Italy)PhenX - respiratorio - capacità di esercizio - cammino 6Minuti, test, protocollo:-:Pt:^Paziente:-:PhenX
Synonyms: Panel PhenX paziente PhenX PhenX - respiratorio - capacità di esercizio - cam Punto nel tempo (episodio)
ru-RURussian (Russian Federation)PhenX - дыхание - нагрузка переносимость - 6 минут ходьба тест протокол:-:ТчкВрм:^Пациент:-:PhenX
Synonyms: Точка во времени;Момент
zh-CNChinese (China)PhenX - 呼吸系统 - 运动能力 - 6 分钟行走试验方案 090601:-:时间点:^患者:-:PhenX
Synonyms: Consensus measures for Phenotypes and eXposures;PhenX;暴露;接触;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 Consensus measures for Phenotypes and eXposures;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 PhenX - 呼吸系统 - 运动(锻炼、锻炼活动、体育锻炼活动、体育锻炼、身体锻炼活动、训练、活动)能力(耐量) - 6 分钟行走(步行、散步、徒步、走路)试验(测试)方案 090601;Consensus measures for Phenotypes and eXposures;PhenX;暴露;接触;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 医嘱套餐 医嘱套餐类 医嘱套餐组 医嘱组 医嘱组.PhenX;组套(组合、医嘱组、套餐、套餐医嘱、医嘱套餐、组合申请、组合项目).PhenX;Consensus measures for Phenotypes and eXposures;PhenX;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标;PhenX 医嘱组 医嘱组合 医嘱组合类 医嘱组套 医嘱组套类 医嘱组类 医疗服务对象;客户;病人;病患;病号;超系统 - 病人 多重;多重型;多重标尺类型;多重精度类型 套餐 套餐医嘱 套餐医嘱组 套餐医嘱组类 实验室医嘱套餐 实验室医嘱套餐类 实验室医嘱组 实验室医嘱组合类 实验室医嘱组套 实验室医嘱组套类 实验室套餐医嘱组 实验室套餐医嘱组类 实验室检验项目医嘱组合类 实验室检验项目组合类 时刻;随机;随意;瞬间 检验医嘱组合类 检验项目医嘱组合类 检验项目组合类 组 组合 组合医嘱 组合类 组套 运动

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=62619-2
Questionnaire definition
https://fhir.loinc.org/Questionnaire/?url=http://loinc.org/q/62619-2