Version 2.77

Status Information

Status
TRIAL

Term Description

A spirometric test requires that the subject take a full, deep breath and then exhale as forcefully as possible into a hand-held portable spirometer. The subject's effort is called the forced expiratory maneuver and most commonly measures the amount and speed of air that is exhaled. The total amount (volume) of air exhaled is called the forced vital capacity (FVC). The amount (volume) of air exhaled in 1 second is called the forced expiratory volume in 1 second (FEV1). While hand-held spirometers are commonly used in clinical research studies, the same results can be obtained from more sophisticated floor-mounted devices that are typically available in a respiratory function testing laboratory. Numerous instructions are embedded in the protocol and in Table 1 of the protocol.
Source: Regenstrief LOINC

Reference Information

Type Source Reference
Citation Consensus measures for Phenotypes and Exposures European Respiratory Journal, 26(2), 319-338.

Panel Hierarchy

Details for each LOINC in Panel LHC-Forms

LOINC Name R/O/C Cardinality Example UCUM Units
62639-0 PhenX - respiratory - spirometry protocol 091601
Indent64591-1 Data type
Indent20053-5 Atmospheric pressure mm[Hg]
Indent60832-3 Room temperature Cel;[degF]
Indent65643-9 Relative humidity (%) %
Indent64592-9 FVC quality attribute
Indent64593-7 FEV1 quality attribute
Indent64594-5 Effort attribute
Indent64595-2 Deleted maneuver
Indent64596-0 Acceptable maneuver
Indent64597-8 Technician quality control code
Indent64598-6 Computer quality code
Indent64599-4 Plateau achieved
Indent64600-0 Review
Indent65644-7 BTPS factor {ratio}
Indent64601-8 Date of review
Indent65645-4 Reviewer initials
Indent65646-2 Manufacturer name
Indent41927-5 Oxygen saturation device Vendor model code
Indent41928-3 Oxygen saturation device Vendor serial number
Indent41925-9 Type of Oxygen saturation device
Indent65652-0 Testing facility name
Indent65647-0 City
Indent52830-7 State, district or territory federal abbreviation Facility
Indent45401-7 Postal code [Location]
Indent65649-6 Country
Indent65650-4 E-mail
Indent65651-2 Phone number
Indent64991-3 Date of observation
Indent64603-4 Calibration result
Indent64991-3 Date of observation
Indent64604-2 Technician ID
Indent64605-9 Maneuver number
Indent30525-0 Age a
Indent3137-7 Body height Measured [in_us];cm;m
Indent3141-9 Body weight Measured [lb_av];kg
Indent46098-0 Sex
Indent64606-7 Race, 2-character race code
Indent21112-8 Birth date {mm/dd/yyyy}
Indent64607-5 Reference values source
Indent65817-9 Reference values correction factor
Indent64608-3 Testing position
Indent65653-8 Test type
Indent65818-7 Medication [Mass/volume] Dose
Indent65866-6 Methacholine [Mass] of Dose mg
Indent19868-9 Forced vital capacity [Volume] Respiratory system by Spirometry L
Indent65654-6 Extrapolated volume mL
Indent20150-9 FEV1 (liters) L
Indent65655-3 FEV6 L
Indent33452-4 Maximum expiratory gas flow Respiratory system airway L/min
Indent19945-5 Gas flow FEV 25%-75% airway L/s
Indent19866-3 Vital capacity [Volume] Respiratory system by Spirometry L
Indent65819-5 Forced expiratory time s
Indent65820-3 Time to PEF
Indent19869-7 Forced vital capacity [Volume] Respiratory system Predicted L
Indent20149-1 FEV1 Predicted L
Indent65656-1 Predicted FEV6 L
Indent19925-7 FEV1/FVC Predicted %
Indent65658-7 Predicted FEV1/FEV6% %
Indent8251-1 Service comment
Indent65660-3 Original sampling interval
Indent65821-1 FEF25% L/s
Indent65822-9 FEF50% L/s
Indent65823-7 FEF75% L/s
Indent65824-5 FEF90% L/s
Indent65661-1 Number of data points {#}
Indent65662-9 Flow data points (mL/s; variable number contained in number of data points)

Fully-Specified Name

Component
PhenX - respiratory - spirometry protocol 091601
Property
-
Time
Pt
System
^Patient
Scale
-
Method
PhenX

Additional Names

Short Name
Resp spirometry proto

Survey Question

Source
PX091601

Basic Attributes

Class
PANEL.PHENX
Type
Clinical
First Released
Version 2.36
Last Updated
Version 2.66
Change Reason
Updated the PhenX ID from "PhenX.<ID>" to "PX<ID>" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.
Panel Type
Panel

Member of these Panels

LOINC Long Common Name
62611-9 PhenX domain - Respiratory

Language Variants Get Info

Tag Language Translation
es-MX Spanish (Mexico) PhenX - respiratorio - protocolo de espirometría 091601:-:Punto temporal:^ Paciente:-:PhenX
it-IT Italian (Italy) PhenX - respiratorio - spirometria, protocollo:-:Pt:^Paziente:-:PhenX
Synonyms: Panel PhenX paziente PhenX Punto nel tempo (episodio)
ru-RU Russian (Russian Federation) PhenX - дыхание - спирометрия протокол:-:ТчкВрм:^Пациент:-:PhenX
Synonyms: Точка во времени;Момент
zh-CN Chinese (China) PhenX - 呼吸系统 - 肺活量测定方案 091601:-:时间点:^患者:-:PhenX
Synonyms: Consensus measures for Phenotypes and eXposures;PhenX;暴露;接触;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 Consensus measures for Phenotypes and eXposures;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 PhenX - 呼吸系统 - 肺活量测定(肺活量测定法、肺量测定、肺量测定法、呼吸量测定、呼吸量测定法)方案 091601;Consensus measures for Phenotypes and eXposures;PhenX;暴露;接触;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 医嘱套餐 医嘱套餐类 医嘱套餐组 医嘱组 医嘱组.PhenX;组套(组合、医嘱组、套餐、套餐医嘱、医嘱套餐、组合申请、组合项目).PhenX;Consensus measures for Phenotypes and eXposures;PhenX;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标;PhenX 医嘱组 医嘱组合 医嘱组合类 医嘱组套 医嘱组套类 医嘱组类 医疗服务对象;客户;病人;病患;病号;超系统 - 病人 多重;多重型;多重标尺类型;多重精度类型 套餐 套餐医嘱 套餐医嘱组 套餐医嘱组类 实验室医嘱套餐 实验室医嘱套餐类 实验室医嘱组 实验室医嘱组合类 实验室医嘱组套 实验室医嘱组套类 实验室套餐医嘱组 实验室套餐医嘱组类 实验室检验项目医嘱组合类 实验室检验项目组合类 时刻;随机;随意;瞬间 检验医嘱组合类 检验项目医嘱组合类 检验项目组合类 组 组合 组合医嘱 组合类 组套

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=62639-0