Status Information

Status
DEPRECATED
Comment
Measure terms were added to match PhenX hierarchy but make it difficult to locate protocols (which contain the set of variables you would use for a particular purpose). They have been deprecated and mapped directly to protocols.

Term Description

Axial length of the eye and central corneal thickness is measured using contact biometry and pachymetry. Depth of the anterior chamber, lens thickness and depth of the posterior chamber can also be obtained. Many eye diseases are known to be associated with either excessively short eyes (nanophthalmos and angle closure glaucoma) or excessively long eyes (degenerative myopia, Stickler's Syndrome). In addition, ocular biometry provides information about the thickness of the lens (for studies of cataract) and the size of the posterior chamber. Axial length of the eye is an essential measurement for selecting the proper intraocular lens when doing cataract surgery. Central corneal thickness influences intraocular pressure measurements (thicker corneas result in artificially higher pressure and thinner corneas in lower pressure). In addition thinner central corneal thickness may be an independent risk factor for optic nerve degeneration in glaucoma.Results of all measurements are then printed. The WG recommends that three readings be taken and recorded from each eye for both axial length and central corneal thickness (measurements in millimeters). The WG recommends that the central corneal thickness-pachymetry measurements be taken first followed by the axial length measurements, as presented in this protocol. This protocol for contact biometry uses the ultrasonic A scan/pachymeter DGH 4000B SBH IOL Computation module. Other instruments can be used to measure ocular biometry including axial length and central corneal thickness. If other instruments are used, the reproducibility of the measurements should be comparable to those acquired with this protocol. In addition, when other instruments are used to collect these measurements, the manufacturer and model of equipment should be recorded. These other devices may require some different steps than are described in this protocol. Investigators should follow the equipment manufacturer's instructions to ensure quality control.

LOINC Names Get Info

Fully-Specified Name
PhenX measure - contact biometry:-:Pt:^Patient:-:PhenX
Long Common Name
Deprecated PhenX measure - contact biometry

Part Model Get Info

  • Component
    PhenX measure - contact biometry
    LP112246-6
    • Analyte
      PhenX measure - contact biometry
      LP112246-6
      • Component Numerator
        PhenX measure - contact biometry
        LP112246-6
        • Component Numerator Core
          PhenX measure - contact biometry
          LP112246-6
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    -
    LP6769-6
  • Time
    Pt
    LP6960-1
  • System
    ^Patient
    LP310005-6
    • System Core
      NULL
       
    • Super System
      Patient
      LP6985-8
  • Scale
    -
    LP7747-1
  • Method
    PhenX
    LP95333-8

Survey Question

PhenX.110100

Basic Attributes

Class
PANEL.PHENX
Type
Clinical
First Released
Version 2.36
Last Updated
Version 2.46 (DEL)

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Μέτρηση PhenX - βιομετρία επαφής:-:Pt:^Ασθενής:-:PhenX
Synonyms: - PANEL.PHENX PHENX Pt Ασθενής Μέτρηση PhenX - βιομετρία επαφής
es-MXSpanish (Mexico)Medida PhenX - biometría de contacto:-:Punto temporal:^ Paciente:-:PhenX
it-ITItalian (Italy)PhenX, misura - biometria contatto:-:Pt:^Paziente:-:PhenX
Synonyms: Panel PhenX paziente PhenX Punto nel tempo (episodio)
ru-RURussian (Russian Federation)PhenX мера - контактная биометрия:-:ТчкВрм:^Пациент:-:PhenX
Synonyms: Точка во времени;Момент
zh-CNChinese (China)PhenX 指标 - 接触式生物测量法:-:时间点:^患者:-:PhenX
Synonyms: Consensus measures for Phenotypes and eXposures;PhenX;暴露;接触;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 Consensus measures for Phenotypes and eXposures;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 PhenX 指标 - 接触式生物测量法(接触式生物测量、接触法生物测量、接触式生物测定法);Consensus measures for Phenotypes and eXposures;PhenX;暴露;接触;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标 医嘱套餐 医嘱套餐类 医嘱套餐组 医嘱组 医嘱组.PhenX;组套(组合、医嘱组、套餐、套餐医嘱、医嘱套餐、组合申请、组合项目).PhenX;Consensus measures for Phenotypes and eXposures;PhenX;表型与暴露共识指标;表现型与暴露共识指标;表型与暴露公认指标;PhenX 医嘱组 医嘱组合 医嘱组合类 医嘱组套 医嘱组套类 医嘱组类 医疗服务对象;客户;病人;病患;病号;超系统 - 病人 多重;多重型;多重标尺类型;多重精度类型 套餐 套餐医嘱 套餐医嘱组 套餐医嘱组类 实验室医嘱套餐 实验室医嘱套餐类 实验室医嘱组 实验室医嘱组合类 实验室医嘱组套 实验室医嘱组套类 实验室套餐医嘱组 实验室套餐医嘱组类 实验室检验项目医嘱组合类 实验室检验项目组合类 时刻;随机;随意;瞬间 检验医嘱组合类 检验项目医嘱组合类 检验项目组合类 组 组合 组合医嘱 组合类 组套

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=62678-8