62707-5PhenX - refractive error - child protocol 111402Trial

Status Information

Status
Trial

Term Description

Refractive error in children is measured using cycloplegic autorefraction with the Retinomax. Eyes undergo cycloplegia after pupillary dilating eyedrops and eight readings of refractive error of each eye are taken with the Retinomax in the Refractions and Keratometry mode. In instances where cycloplegic autorefraction cannot be obtained on an eye or when it is of poor quality (Retinomax confidence rating <= 7), cycloplegic retinoscopy is performed to obtain a measure of refractive error. This protocol uses Retinomax to measure refractive error in children. Other instruments can be used to measure refractive error. If other instruments are used, the reproducibility of the measurements should be comparable to those acquired with this protocol. In addition, when other instruments are used to collect these measurements, the manufacturer and model of equipment should be recorded. These other devices may require some different steps than are described in this protocol. Investigators should follow the equipment manufacturer's instructions to ensure quality control.
Source: Regenstrief LOINC

Panel Hierarchy
Details for each LOINC in Panel LHC-Forms

LOINC Name R/O/C Cardinality Example UCUM Units
62707-5 PhenX - refractive error - child protocol 111402
Indent46496-6 Agency patient number [CMS Assessment]
Indent65882-3 Model of instrument used to measure refractive error
Indent65529-0 Corneal vertex distance measured by Retinomax mm
Indent65890-6 Spherical power [Inverse Length] Right eye [diop]
Indent65892-2 Cylindrical power [Inverse Length] Right eye deg
Indent65891-4 Cylinder axis Right eye deg
Indent65893-0 Best corrected visual acuity Right eye [ft_us]/[ft_us]
Indent65894-8 Spherical power [Inverse Length] Left eye [diop]
Indent65896-3 Cylindrical power [Inverse Length] Left eye [diop]
Indent65895-5 Cylinder axis Left eye deg
Indent65897-1 Best corrected visual acuity Left eye [ft_us]/[ft_us]
Indent65882-3 Model of instrument used to measure refractive error
Indent65890-6 Spherical power [Inverse Length] Right eye [diop]
Indent65892-2 Cylindrical power [Inverse Length] Right eye deg
Indent65891-4 Cylinder axis Right eye deg
Indent65894-8 Spherical power [Inverse Length] Left eye [diop]
Indent65896-3 Cylindrical power [Inverse Length] Left eye [diop]
Indent65895-5 Cylinder axis Left eye deg

Fully-Specified Name

Component
PhenX - refractive error - child protocol 111402
Property
-
Time
Pt
System
^Patient
Scale
-
Method
PhenX

Additional Names

Short Name
Refractive error child proto

Basic Attributes

Class
PANEL.PHENX
Type
Clinical
First Released
Version 2.36
Last Updated
Version 2.66
Change Reason
Updated the PhenX ID from "PhenX.<ID>" to "PX<ID>" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.
Panel Type
Panel

Survey Question

Source
PX111402

Member of these Panels

LOINC Long Common Name
62677-0 PhenX domain - Ocular

Language Variants Get Info

zh-CNChinese (CHINA)
PhenX - 屈光不正 - 儿童方案 111402:-:时间点:^患者:-:PhenX
it-ITItalian (ITALY)
PhenX - errori di rifrazione - bambino, protocollo:-:Pt:^Paziente:-:PhenX
ru-RURussian (RUSSIAN FEDERATION)
PhenX - рефракционная ошибка - детский протокол:-:ТчкВрм:^Пациент:-:PhenX

LOINC FHIR® API Example - CodeSystem Request Get Info

https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=62707-5