66745-1
Clot Lysis [Length fraction] in Blood by Thromboelastography --30 minutes post maximum clot amplitude
Active
Part Description
LP69276-1 Thromboelastography
Thromboelastography (TEG) is a viscoelastic test of hemostasis. In TEG, whole blood is added to a cup in which a pin is suspended, the cup is rotated, and as the clot forms, the rotational force is transferred to the pin. The torsion of the pin is transformed into a graphic record of the physical shape of a clot during fibrin formation and lysis. TEG can provide information about the status of coagulation factors, platelet function and fibrinolysis in whole blood. TEG is primarily used for assessment of hemostasis after cardiopulmonary bypass, during liver transplant surgery, or hemorrhaging episodes. TEG parameters are also used as part of the guiding algorithms for plasma, platelet and cryoprecipitate transfusions.
Copyright Copyright © 1995-2009
Source: Mayo Medical Laboratories
LOINC Names Get Info
- Fully-Specified Name
- Coagulum lysis^30M post maximum clot amplitude:
LenFr: Pt: Bld: Qn: Thromboelastography - Long Common Name
- Clot Lysis [Length fraction] in Blood by Thromboelastography --30 minutes post maximum clot amplitude
- Short Name
- Clot Lysis 30M p MA LenFr Bld TEG
- Display Name
- Clot Lysis 30 Min post maximum clot amplitude TEG (Bld) [Length fraction]
- Consumer Name Alpha Get Info
- Clot lysis 30 min after max clot amplitude, Blood
Part Model Get Info
- Component
- Coagulum lysis^30M post maximum clot amplitude
LP307715-5
- Analyte
- Coagulum lysis
LP15985-2
- Challenge
- 30M post maximum clot amplitude
LP129061-0
- Adjustment
- NULL
- Count
- NULL
- Property
- LenFr
LP6823-1
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- Bld
LP7057-5
- System Core
- Bld
LP7057-5
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- Thromboelastography
LP69276-1
Basic Attributes
- Class
- COAG
- Type
- Laboratory
- First Released
- Version 2.38
- Last Updated
- Version 2.73 (MIN)
- Change Reason
- Release 2.67: ORDER_OBS: Updated Order_Obs from "Observation" to "Both"
- Order vs. Observation
- Both
- Common Test Rank Get Info
- 3768
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 67790-6 | Thromboelastography panel - Blood |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| cs-CZ | Czech (Czechia) | Lýza koagula^minut po dosažení maximální amplitudy: |
| el-GR | Greek (Greece) | Λύση πήγματος^30 λεπτά μετά το μέγιστο εύρος θρόμβου: Synonyms: 30 λεπτά μετά το μέγιστο εύρος θρόμβου COAG LenFr Pt Qn Αίμα Θρομβοελαστογραφία Θρόμβος Λύση πήγματος |
| es-ES | Spanish (Spain) | Lisis del coágulo^30M despúes de la amplitud máxima del coágulo: Synonyms: Cuantitativo |
| es-MX | Spanish (Mexico) | Lisis del coágulo ^30 M después de la amplitud máxima del coágulo: |
| fr-FR | French (France) | Temps de lyse des euglobulines^T30min après amplitude maximale du caillot: |
| it-IT | Italian (Italy) | Tempo di lisi del coagulo^30Minuti post massima ampiezza coagulo: Synonyms: 30 minuti dopo massima ampiezza del coagulo Frazione di lunghezza Lisi del coagulo Punto nel tempo (episodio) Sangue Studio di coagulazione TEG |
| nl-NL | Dutch (Netherlands) | stolsellysis^30 min na maximum stollingsamplitude: Synonyms: 30M na maximum stollingsamplitude coagulatiemethode |
| pl-PL | Polish (Poland) | Liza skrzepu^30min po maksimum amplitudy skrzepu: Synonyms: 30 minut po maksimum amplitudy skrzepu Liza skrzepu po 30M od maksymalnej amplitudy skrzepu |
| tr-TR | Turkish (Turkey) | Pıhtı lizisi^30dk snr maksimum pıhtı büyüklüğü: |
| zh-CN | Chinese (China) | 血凝块溶解^在达到最大凝固幅度之后30分钟: Synonyms: XXX刺激 - 在...之后 之后于... 优球朊凝块溶解时间; |
Example Units
| Unit | Source |
|---|---|
| % | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://