69578-3
Diffusion capacity.carbon monoxide/Alveolar volume adjusted for hemoglobin
Active
Part Description
LP72464-8 Diffusion capacity.carbon monoxide
Diffusing capacity (DLCO) is the carbon monoxide uptake from a single inspiration in a standard time (usually 10 sec). Since air consists of very minute or trace quantities of carbon monoxide (CO), 10 seconds is considered to be the standard time for inhalation, then rapidly blow it out (exhale). The exhaled gas is tested to determine how much of the tracer gas was absorbed during the breath. This will pick up diffusion impairments, for instance in pulmonary fibrosis. This must be corrected for anemia (because rapid CO diffusion is dependent on hemoglobin in RBC's; a low hemoglobin concentration, anemia, will reduce DLCO) and pulmonary hemorrhage (excess RBC's in the interstitium or alveoli can absorb CO and artificially increase the DLCO capacity). Atmospheric pressure and/or altitude will also affect measured DLCO, and so a correction factor is needed to adjust for standard pressure. Online calculators are available to correct for hemoglobin levels and altitude and/or pressure where the measurement was taken.
Copyright Text is available under the Creative Commons Attribution/Share-Alike License. See http://creativecommons.org/licenses/by-sa/3.0/ for details.
Source: Wikipedia,
Wikipedia
LOINC Names Get Info
- Fully-Specified Name
- Diffusion capacity.carbon monoxide/Alveolar volume^^adjusted for hemoglobin:
Inverse VI: Pt: Respiratory system: Qn: - Long Common Name
- Diffusion capacity.carbon monoxide/Alveolar volume adjusted for hemoglobin
- Short Name
- Diff cap.CO/Alv vol Hgb adj
Part Model Get Info
- Component
- Diffusion capacity.carbon monoxide/Alveolar volume^^adjusted for hemoglobin
LP308808-7
- Analyte
- Diffusion capacity.carbon monoxide/Alveolar volume
LP285907-4
- Challenge
- NULL
- Adjustment
- adjusted for hemoglobin
LP71889-7
- Count
- NULL
- Property
- Inverse VI
LP6821-5
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- Respiratory system
LP7556-6
- System Core
- Respiratory system
LP7556-6
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- NULL
Basic Attributes
- Class
- PULM
- Type
- Clinical
- First Released
- Version 2.40
- Last Updated
- Version 2.70 (MIN)
- Change Reason
- Corrected UCUM units from L/min/mm{Hg} to L/min/[Hg]
- Order vs. Observation
- Observation
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ικανότητα διάχυσης.μονοξείδιο του άνθρακα/Κυψελιδικός όγκος^^προσαρμοσμένο για αιμοσφαιρίνη: Synonyms: (Ικανότητα διάχυσης Inverse VI Pt PULM Qn Αιμοσφαιρίνη Αναπνευστικό Αναπνευστικό σύστημα Ικανότητα διάχυσης Ικανότητα διάχυσης.μονοξείδιο του άνθρακα Κυψελιδικός όγκος Μονοξείδιο του άνθρακα Όγκος προσαρμοσμένο προσαρμοσμένο για αιμοσφαιρίνη |
| es-MX | Spanish (Mexico) | Capacidad de difusión Monóxido de carbono / Volumen alveolar ^^ ajustado para hemoglobina: |
| it-IT | Italian (Italy) | Capacità di diffusione.monossido di carbonio/Volume alveolare^^regolato per emoglobina: Synonyms: Gestione ventilazione polmonare Punto nel tempo (episodio) |
| ru-RU | Russian (Russian Federation) | Диффузионная способность.углерод монооксид/Альвеолярный объём^^поправленный на гемоглобин: Synonyms: Количественный Точка во времени; |
| zh-CN | Chinese (China) | 弥散量.一氧化碳/肺泡容积^^经过针对血红蛋白而调整的: Synonyms: (弥散容量 CO 可用数量表示的; |
Example Units
| Unit | Source |
|---|---|
| L/min/mm[Hg] | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://