Term Description

Because of the confusion that occurs in countries that report results as both decimal fraction and percent, this property was created to represent decimal fractions that are reported without units.

Part Description

LP21258-6   Oxygen saturation
Oxygen saturation (sO2) is defined as the ratio of oxyhemoglobin to "active" hemoglobin (oxyhemoglobin + deoxyhemoglobin). Some say the term oxygen saturation has been erroneously redefined with a denominator of "total" instead of "active" hemoglobin, an ambiguity that can sometimes create confusion when viewing reported values from different instruments (Anesth Analg. 2007 Dec;105(6 Suppl):S5-9.) Oxygen saturation is commonly measured by blood gas analyzers and pulse oximetry. Source: Regenstrief LOINC

LOINC Names Get Info

Fully-Specified Name
Oxygen saturation:MFr.DF:Pt:BldMV:Qn:
Long Common Name
Oxygen saturation [Pure mass fraction] in Mixed venous blood
Short Name
SaO2 DF BldMV
Display Name
SaO2% (BldMV) [Pure mass fraction]
Consumer Name Alpha Get Info
SaO2%, Blood

Part Model Get Info

  • Component
    Oxygen saturation
    LP21258-6
    • Analyte
      Oxygen saturation
      LP21258-6
      • Component Numerator
        Oxygen saturation
        LP21258-6
        • Component Numerator Core
          Oxygen saturation
          LP21258-6
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    MFr.DF
    LP150070-3
  • Time
    Pt
    LP6960-1
  • System
    BldMV
    LP7071-6
    • System Core
      BldMV
      LP7071-6
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    NULL
     

Basic Attributes

Class
CHEM
Type
Laboratory
First Released
Version 2.40
Last Updated
Version 2.73 (MIN)
Order vs. Observation
Observation
Common Test Rank Get Info
4639

Language Variants Get Info

TagLanguageTranslation
cs-CZCzech (Czechia)Kyslík saturace:Hmotnostní podíl desetinný:Časový bod:Krev venózní smíšená:Kvantitativní:
el-GRGreek (Greece)Κορεσμός οξυγόνου:MFr.DF:Pt:Μάζα/όγκος αίματος:Qn:
Synonyms: CHEM MFr.DF Pt Qn Κορεσμός οξυγόνου Μάζα/όγκος αίματος Οξυγόνο
es-ESSpanish (Spain)Saturación de Oxígeno:MFr.DF:Punto temporal:Sangre venosa mixta:Qn:
Synonyms: Cuantitativo
es-MXSpanish (Mexico)Saturación de oxígeno:Fracción de masa decimal:Punto temporal:Sangre venosa mixta:Cuantitativo:
fr-CAFrench (Canada)Saturation en oxygène:Fraction de masse.DF:Temps ponctuel:Sang veineux mélangé:Quantitatif:
fr-FRFrench (France)Oxygène saturation:Fraction massique (sans unité):Ponctuel:Sang mêlé veineux:Numérique:
it-ITItalian (Italy)Saturazione dell'ossigeno:MFr.DF:Pt:Sangue ven mis:Qn:
Synonyms: Chimica Frazione di massa decimale Punto nel tempo (episodio) Sangue venoso misto
nl-NLDutch (Netherlands)zuurstofverzadiging:decimale massafractie:moment:gemengd veneus bloed:kwantitatief:
pl-PLPolish (Poland)Wysycenie tlenem:frakcja masowa:punkt w czasie:krew żylna mieszana:ilościowy:
ru-RURussian (Russian Federation)Кислородом сатурация:МасДоля.ДецДоля:ТчкВрм:КрСмВ:Колич:
Synonyms: Десятичное масс отношение Количественный Кровь смешанная венозная Насыщение кислородом Точка во времени;Момент
tr-TRTurkish (Turkey)Oksijen satürasyonu:KütlFr.Ondlk:Zmlı:KanKarşVen:Kant:
Synonyms: Oksijen doymuşluğu
zh-CNChinese (China)氧饱和度:质量分数.小数型:时间点:混合静脉全血:定量型:
Synonyms: O2;tO2;总氧;氧气 全血 - 混合静脉;全血 - 混合静脉性;混合静脉血;血液 - 混合静脉;血液 - 混合静脉性 化学;化学检验项目;化学检验项目类;化学类;化学试验;非刺激耐受型化学检验项目;非刺激耐受型化学检验项目类;非刺激耐受型化学试验;非刺激耐受型化学试验类 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 时刻;随机;随意;瞬间 质量分数.小数;小数型质量分数;质量分数.DF 饱和 饱和状态 饱和程度

Example Units

UnitSource
%Example UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=71846-0