78179-9
Mitral valve Orifice area by US.2D+Measured by planimetry
Active
Part Description
LP32280-7 US.2D+Measured by planimetry
Two-dimensional (2D) imaging is one of three ultrasound modes (2D, M-mode, and Doppler) used for cardiac imaging. 2D imaging is the primary method of cardiac imaging and allows structures to be viewed moving in real time in a cross-section of the heart (two dimensions). It is used to detect abnormal anatomy or motion. The most common cross-sectional views are the parasternal long axis, the parasternal short axis, and the apical view. The gastric or subcostal and suprasternal views are also commonly used. [NCBI Books: NBK2215]
Source: Regenstrief LOINC,
NCBI Books: NBK2215
LOINC Names Get Info
- Fully-Specified Name
- Orifice area:
Area: Pt: Mitral valve: Qn: US.2D+Measured by planimetry - Long Common Name
- Mitral valve Orifice area by US.2D+Measured by planimetry
- Short Name
- MV Orifice area US.2D.PLN
Part Model Get Info
- Component
- Orifice area
LP212500-5
- Analyte
- Orifice area
LP212500-5
- Component Numerator
- Orifice area
LP212500-5
- Component Numerator Core
- Orifice area
LP212500-5
- Component Numerator Core Suffix
- NULL
- Component Denominator
- NULL
- Component Denominator Core
- NULL
- Component Denominator Core Suffix
- NULL
- Challenge
- NULL
- Adjustment
- NULL
- Count
- NULL
- Property
- Area
LP6782-9
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- Mitral valve
LP7424-7
- System Core
- Mitral valve
LP7424-7
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- US.2D+Measured by planimetry
LP32280-7
Basic Attributes
- Class
- CARD.US
- Type
- Clinical
- First Released
- Version 2.54
- Last Updated
- Version 2.67 (NAM)
- Change Reason
- Release 2.67: COMPONENT: Updated Component to Orifice area for consistency across terms
- Order vs. Observation
- Observation
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Περιοχή στομίου: Synonyms: CARD.US Pt Qn US.2D Επιφάνεια ΗΠΑ Μετρούμενο Μιτροειδής βαλβίδα Περιοχή στομίου Υπερηχογράφημα.2D+Μετρηθέν με επιπεδομετρία |
| es-MX | Spanish (Mexico) | Área del orificio: |
| it-IT | Italian (Italy) | Area dell'orifizio: Synonyms: Eco Ecografia 2D Ecografia 2D.planimetria Ecografia cardiaca Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 口面积: Synonyms: 二维超声; |
Example Units
| Unit | Source |
|---|---|
| cm2 | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://