Part Description

LP6617-7   US.doppler
Doppler ultrasound detects the shift in frequency of ultrasound signals reflected from moving objects. Conventional Doppler techniques assess the velocity of blood flow by measuring high-frequency, low-amplitude signals from small, fast-moving blood cells. PMID: 16534017 Source: Regenstrief LOINC, PMID: 16534017

LOINC Names Get Info

Fully-Specified Name
Regurgitant blood duration of 1 to 3 meters per second flow velocity:Time:Pt:Mitral valve:Qn:US.doppler
Long Common Name
Mitral valve Regurgitant blood duration of 1 to 3 meters per second flow velocity by US.doppler
Short Name
MV Dur of 1-3 m/s regurg flow vel DOP

Part Model Get Info

  • Component
    Regurgitant blood duration of 1 to 3 meters per second flow velocity
    LP212116-0
    • Analyte
      Regurgitant blood duration of 1 to 3 meters per second flow velocity
      LP212116-0
      • Component Numerator
        Regurgitant blood duration of 1 to 3 meters per second flow velocity
        LP212116-0
        • Component Numerator Core
          Regurgitant blood duration of 1 to 3 meters per second flow velocity
          LP212116-0
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Time
    LP6879-3
  • Time
    Pt
    LP6960-1
  • System
    Mitral valve
    LP7424-7
    • System Core
      Mitral valve
      LP7424-7
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    US.doppler
    LP6617-7

Basic Attributes

Class
CARD.US
Type
Clinical
First Released
Version 2.56
Last Updated
Version 2.71 (MIN)
Order vs. Observation
Observation

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Διάρκεια ροής αίματος παλινδρόμησης 1 έως 3 μέτρα ανά δευτερόλεπτο:Time:Pt:Μιτροειδής βαλβίδα:Qn:Υπερηχογράφημα.doppler
Synonyms: CARD.US Pt Qn Time Αίμα Διάρκεια Διάρκεια ροής αίματος παλινδρόμησης 1 έως 3 μέτρα ανά δευτερόλεπτο ΗΠΑ Μιτροειδής βαλβίδα Ροή Υπερηχογράφημα.doppler
es-MXSpanish (Mexico)Duración de la sangre regurgitante de 1 a 3 metros por segundo velocidad de flujo:Tiempo:Punto temporal:La válvula mitral:Cuantitativo:US.doppler
it-ITItalian (Italy)Tempo di rigurgito sanguigno da 1 a 3 metri per secondo della velocità del flusso:Tempo:Pt:Valvola mitrale:Qn:Eco.doppler
Synonyms: Eco Ecografia cardiaca Ecografia.doppler Punto nel tempo (episodio) Tempo (e.g. secondi)
zh-CNChinese (China)流速为 1 至 3 米每秒的血液反流持续时间:时间:时间点:二尖瓣:定量型:超声.多普勒
Synonyms: Ⅰ 2nd Ⅲ I III 三 僧帽瓣 动态 叁 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 心脏病学 心脏病学.超声;心脏超声 心脏超声.多普勒 持续时长;时长;时间长度;为时;为期;历时;延续时间;持久时间 时刻;随机;随意;瞬间 时间(如秒);时间(如秒数) 流 流速为 1 至 3 米每秒(米每秒钟、m/s)的血液反流持续时间(持续时长、时长、时间长度、时间、时间长短、为时、为期、历时、延续时间、持久时间、持续期) 流量;流速;流体 第 2 个 第二 第二(Second,2nd) 第二个 血;全血 超声检查方法;超声检查法;超声波;超声波检查方法;超声波检查法

Example Units

UnitSource
msExample UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=81387-3