Term Description

The maximum clot strength in the presence of activator F, as measured by the amplitude of resonance of the blood meniscus as the blood sample clots. In this test, thrombin activity is blocked, and Activator F is used to activate fibrinogen in order to measure the clot strength based on fibrin. This term was created for, but is not limited in use to, the Submitter's test kit, the TEG6s PlateletMapping ADP Assay Cartridge for heparinized blood.

LOINC Names Get Info

Fully-Specified Name
Maximum clot strength amplitude:Len:Pt:Bld:Qn:Thromboelastography.resonance.activator F induced
Long Common Name
Maximum clot strength amplitude [Length] in Blood by Thromboelastography.resonance.activator F induced
Short Name
Max clot strength amp Bld TEG..res.ac
Display Name
Maximum clot strength amplitude (Bld) [Length]
Consumer Name Alpha Get Info
Maximum clot strength amplitude, Blood

Part Model Get Info

  • Component
    Maximum clot strength amplitude
    LP449127-2
    • Analyte
      Maximum clot strength amplitude
      LP449127-2
      • Component Numerator
        Maximum clot strength amplitude
        LP449127-2
        • Component Numerator Core
          Maximum clot strength amplitude
          LP449127-2
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Len
    LP6822-3
  • Time
    Pt
    LP6960-1
  • System
    Bld
    LP7057-5
    • System Core
      Bld
      LP7057-5
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    Thromboelastography.resonance.activator F induced
    LP448903-7

Basic Attributes

Class
COAG
Type
Laboratory
First Released
Version 2.65
Last Updated
Version 2.83 (MIN)
Order vs. Observation
Observation

Member of these Panels

LOINCLong Common Name
91124-8Platelet function with adenosine diphosphate induction panel - Blood by Resonance TEG
107573-8Platelet mapping (function) panel - Blood by Resonance TEG

Language Variants Get Info

TagLanguageTranslation
cs-CZCzech (Czechia)Amplituda maximální aktivátorem F indukovaná:Délka:Časový bod:Krev:Kvantitativní:Rezonanční tromboelastografie (TEG)
el-GRGreek (Greece)Μέγιστο εύρος ισχύος θρόμβου.επαγόμενο από ενεργοποιητή F:Len:Pt:Αίμα:Qn:Θρομβοελαστογραφία.συντονισμού
Synonyms: COAG Len Pt Qn Αίμα Θρομβοελαστογραφία Θρομβοελαστογραφία.συντονισμού Θρόμβος Ισχύς θρόμβου Μέγιστο εύρος ισχύος θρόμβου.επαγόμενο από ενεργοποιητή F Περιεκτικότητα
es-ESSpanish (Spain)Amplitud máxima de fuerza de coagulación inducida por activador F:Longitud:Punto temporal:Sangre:Qn:Tromboelastografía. Resonancia
Synonyms: Cuantitativo
es-MXSpanish (Mexico)Amplitud máxima de la fuerza del coágulo. Inducida por el activador F:Largo:Punto temporal:Sangre:Cuantitativo:Resonancia TEG
fr-FRFrench (France)Caillot résistance amplitude maximale induite par activateur F:Longueur:Ponctuel:Sang:Numérique:Thromboélastographie par résonance
it-ITItalian (Italy)Ampiezza massima della forza del coagulo:Len:Pt:Sangue:Qn:Tromboelastografia.risonanza.indotta da attivatore F
Synonyms: Forza del coagulo Lunghezza Punto nel tempo (episodio) Risonanza TEG Sangue Studio di coagulazione TEG
zh-CNChinese (China)最大凝块强度幅度.激活剂 F 诱导型:长度:时间点:全血:定量型:血栓弹力描记术.共振
Synonyms: 体力;力;强度;浓度;规格;药品规格;药品规格或剂量 凝血功能;凝血功能试验;凝血过程;血液凝固;血液凝固功能;血液凝固过程 凝血弹性描记法;血栓弹性描记法;血栓弹力图;Thromboelastography;TEG 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 时刻;随机;随意;瞬间 最大凝块强度幅度.激活剂(激活剂) F 诱导型(诱导的) 纤维蛋白凝块强度;血液凝块强度;血凝块强度 血;血液 血栓弹力描记术(凝血弹性描记法;血栓弹性描记法;血栓弹力、TEG).共振(谐振、共振式、谐振式);共振式血栓弹力描记术;Resonance thromboelastography;RTG;RTEM 长;长短

Example Units

UnitSource
mmExample UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=91126-3