91982-9
Specific airway resistance measured/predicted by Plethysmograph body box
Active
Part Description
LP310432-2 Specific resistance.airway
Specific airway resistance (sRaw) reflects airway resistance (Raw) that has been adjusted for lung volume. It is measured by plethysmography during normal breathing (i.e., tidal breathing), does not require special maneuvers, and is independent of height and sex, so it is commonly used in pediatrics and can be used for children as young as 2. The relationship between sRaw and Raw is: sRaw = Raw * TGV, where TGV is thoracic gas volume. There are different methods used for calculating sRaw from the data gathered during plethysmography, including:
1. sRtot (total specific resistance), which uses the flow measurements at the maximum change in pressure
2. sRaw Vmax, which uses the the measurements at the maximum flow
3. sRaw0.5, which uses the measurements where the flow reaches 0.5 L/s
Specifying the method used to calculate sRaw is important for interpreting the results.
PMID: 16002957
Source: Regenstrief LOINC
LOINC Names Get Info
- Fully-Specified Name
- Specific resistance.airway/predicted:
RelFldResist: Stdy^mean: Respiratory system.airway: Qn: Plethysmograph.body box - Long Common Name
- Specific airway resistance measured/predicted by Plethysmograph body box
- Short Name
- Specific airway resist meas/pred Pleth
Part Model Get Info
- Component
- Specific resistance.airway/predicted
LP406703-1
- Analyte
- Specific resistance.airway/predicted
LP406703-1
- Component Numerator
- Specific resistance.airway
LP310432-2
- Component Numerator Core
- Specific resistance.airway
LP310432-2
- Component Numerator Core Suffix
- NULL
- Component Denominator
- Predicted
LP140658-8
- Component Denominator Core
- Predicted
LP140658-8
- Component Denominator Core Suffix
- NULL
- Challenge
- NULL
- Adjustment
- NULL
- Count
- NULL
- Property
- RelFldResist
LP310434-8
- Time
- Stdy^mean
LP281592-8
- System
- Respiratory system.airway
LP7558-2
- System Core
- Respiratory system.airway
LP7558-2
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- Plethysmograph.body box
LP6453-7
Basic Attributes
- Class
- PULM
- Type
- Clinical
- First Released
- Version 2.66
- Last Updated
- Version 2.66 (ADD)
- Order vs. Observation
- Both
Formula (Readable)
sRaw measured/sRaw predicted, where sRaw is specific airway resistance.
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ειδική αντίσταση.αεραγωγός/Προβλεπόμενη: Synonyms: PULM Qn RelFldResist Stdy Αναπνευστικό Αναπνευστικό σύστημα Αναπνευστικό σύστημα.αεραγωγός Αντίσταση.αεραγωγός Ειδική αντίσταση.αεραγωγός μέσο Πληθυσμιογράφος.ολόσωμος θάλαμος Προβλεπόμενη |
| es-MX | Spanish (Mexico) | Resistencia específica vía aérea / prevista: |
| it-IT | Italian (Italy) | Resistenza specifica.vie aeree/Previsto: Synonyms: Gestione ventilazione polmonare Pletismografo o body box Resistenza relativa ai fluidi Via aeree dell''apparato respiratorio |
| zh-CN | Chinese (China) | 特异性阻力.气道/预计法: Synonyms: RelFldResist; |
Example Units
| Unit | Source |
|---|---|
| % | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://