Term Description

This panel includes terms to report results related to intermittent hemodialysis, including parameters related to the pressures, volumes and rates of various components in the dialysis circuit, information about the patient's dialysis access, and lab results. Intermittent hemodialysis is prescribed for patients with chronic renal failure and typically involves three- to six-hour dialysis sessions three times a week. During hemodialysis, a concentration gradient between the dialysate fluid and the patient's blood causes solutes in the blood, which would normally be filtered by healthy kidneys, to diffuse across the dialysis membrane into the dialysate. PMID: 18360553

Panel Hierarchy

Details for each LOINC in Panel LHC-Forms

LOINCNameR/O/CCardinalityExample UCUM Units
99737-9Intermittent hemodialysis panel
Indent57835-1Appearance of Dialysis fluid
Indent51617-9Color of Dialysis fluid
Indent12457-8Volume of Dialysis fluidmL
Indent53654-0pH of Dialysis fluid[pH]
Indent5919-6Creatinine [Mass/volume] in Dialysis fluidmg/dL
Indent2343-2Glucose [Mass/volume] in Dialysis fluidmg/dL
Indent2775-5Phosphate [Mass/volume] in Dialysis fluidmg/dL
Indent2820-9Potassium [Moles/volume] in Dialysis fluidmmol/L
Indent5920-4Protein [Mass/volume] in Dialysis fluidg/L
Indent2949-6Sodium [Moles/volume] in Dialysis fluidmmol/L
Indent45302-7Urea [Moles/volume] in Dialysis fluidmmol/L
Indent5918-8Urea nitrogen [Mass/volume] in Dialysis fluidmg/dL
Indent99738-7Hemodialysis fluid removal goal [Volume]mL
Indent99739-5Hemodialysis fluid removed [Volume]mL
Indent99740-3Hemodialysis fluid removed [Volume] 1 hourmL
Indent99741-1Ultrafiltrate volume removedmL
Indent99710-6Venous lumen volume Dialysis cathetermL
Indent99711-4Blood flow rate Renal replacement therapy circuitmL/min
Indent99712-2Dialysate flow rate Renal replacement therapy circuitmL/min
Indent99713-0Post-filter replacement fluid rate Renal replacement therapy circuitmL/min
Indent99714-8Pre-filter replacement fluid rate Renal replacement therapy circuitmL/min
Indent99715-5Dialysis access site
Indent99716-3Dialysis access site appearance
Indent99717-1Access pressure Renal replacement therapy circuitmm[Hg]
Indent99718-9Effluent pressure Renal replacement therapy circuitmm[Hg]
Indent99719-7Filter pressure Renal replacement therapy circuitmm[Hg]
Indent99720-5Transmembrane pressure Renal replacement therapy circuitmm[Hg]
Indent99721-3Return pressure Renal replacement therapy circuitmm[Hg]
Indent99731-2Pressure drop Renal replacement therapy circuitmm[Hg]
Indent99732-0Dialysate fluid Renal replacement therapy circuit
Indent99733-8Replacement fluid Renal replacement therapy circuit
Indent99734-6Arterial lumen volume Dialysis cathetermL
Indent99735-3Ultrafiltrate volume removed 1 hourmL
Indent72050-8Dialysis access
Indent99736-1Reason for filter change Renal replacement therapy circuit

LOINC Names Get Info

Fully-Specified Name
Intermittent hemodialysis panel:-:Pt:^Patient:-:
Long Common Name
Intermittent hemodialysis panel
Short Name
Intermittent hemodialysis panel

Part Model Get Info

  • Component
    Intermittent hemodialysis panel
    LP430880-7
    • Analyte
      Intermittent hemodialysis panel
      LP430880-7
      • Component Numerator
        Intermittent hemodialysis panel
        LP430880-7
        • Component Numerator Core
          Intermittent hemodialysis panel
          LP430880-7
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    -
    LP6769-6
  • Time
    Pt
    LP6960-1
  • System
    ^Patient
    LP310005-6
    • System Core
      NULL
       
    • Super System
      Patient
      LP6985-8
  • Scale
    -
    LP7747-1
  • Method
    NULL
     

Basic Attributes

Class
PANEL.CLIN
Type
Clinical
First Released
Version 2.72
Last Updated
Version 2.72 (ADD)
Order vs. Observation
Order
Panel Type
Convenience group

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Πίνακας διαλείπουσας αιμοκάθαρσης:-:Pt:^Ασθενής:-:
Synonyms: - CLIN PANEL.CLIN Pt Ασθενής Πίνακας διαλείπουσας αιμοκάθαρσης
it-ITItalian (Italy)Emodialisi intermittente, panel:-:Pt:^Paziente:-:
Synonyms: Clinico Panel di emodialisi intermittente paziente Punto nel tempo (episodio) Set clinico NEC (non classificato altrove)
zh-CNChinese (China)间歇性血液透析组套:-:时间点:^患者:-:
Synonyms: 医嘱套餐 医嘱套餐类 医嘱套餐组 医嘱组 医嘱组.临床;组套(组合、医嘱组、套餐、套餐医嘱、医嘱套餐、组合申请、组合项目).临床(CLIN、Clinical) 医嘱组合 医嘱组合类 医嘱组套 医嘱组套类 医嘱组类 医疗服务对象;客户;病人;病患;病号;超系统 - 病人 多重;多重型;多重标尺类型;多重精度类型 套餐 套餐医嘱 套餐医嘱组 套餐医嘱组类 实验室医嘱套餐 实验室医嘱套餐类 实验室医嘱组 实验室医嘱组合类 实验室医嘱组套 实验室医嘱组套类 实验室套餐医嘱组 实验室套餐医嘱组类 实验室检验项目医嘱组合类 实验室检验项目组合类 时刻;随机;随意;瞬间 检验医嘱组合类 检验项目医嘱组合类 检验项目组合类 组 组合 组合医嘱 组合类 组套 间歇性血液透析(间歇性血液透析治疗、间歇性血液透析疗法、间断性血液透析)组套(组合、医嘱组、套餐、套餐医嘱、医嘱套餐、组合申请、组合项目)

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=99737-9
Questionnaire definition
https://fhir.loinc.org/Questionnaire/?url=http://loinc.org/q/99737-9