LOINC terms are not intended to transmit all possible information about a test or observation. They are only intended to identify the test result or clinical observation. Other fields in the message can transmit the identity of the source laboratory and special details about the sample. For instance, the result code may identify a blood culture, but the message source code can be more specific and identify the sample as pump blood.

The level of detail in the LOINC Fully-Specified Name was intended to distinguish tests that are usually distinguished as separate test results within the master file of existing laboratory systems. Indeed, at the outset, we used the master files from seven U.S. laboratories to shape this effort, and requests from commercial labs and hospitals continue to shape the content of the LOINC effort. Therefore, certain parameters and descriptions pertaining to test performance are specifically excluded from the fully specified test name. These parameters will typically be reported in separate fields (attributes) of a test/observation report message, not as part of the observation name. Attributes that we explicitly exclude from the fully specified name are:

  • the instrument used in testing
  • fine details about the sample or the site of collection, such as “right antecubital fossa”
  • the priority of the testing, e.g., whether stat or routine
  • who verified the result
  • the size of the sample collected
  • the place of testing (e.g., home, bedside, clinical lab)

In the case of laboratory tests, the name does include information that identifies the type of sample (or specimen). However, the “sample” part of the name is not meant to carry all possible information about the sample, but only enough to indicate significant differences in the result and to reflect current usage in test names. For example, laboratories usually define urine sodium, sweat sodium, and serum sodium as different tests because each of these has a different normal range. But laboratories do not define different tests to distinguish the concentration of arterial serum sodium from venous serum sodium, though the lab may report that the sample was venous or arterial in another part of the report. We are guided by the pragmatics of conventional usage. If laboratories define separate tests for the same measurements done on different specimens (this usually implies a well-defined normal range difference), we will define different “result-able” tests in our dictionary. If they do not, we will not.

The extent to which we include methods as part of the name is also guided by pragmatics. We distinguish tests/observations by the type of method used to produce the results only if a given type of method has an important effect on the interpretation of the result. This is a complex subject and it is difficult to fully describe our rationale in this guide. Where laboratories do not tend to include the method in the name (e.g., most of chemistry) we do not include the method in the name. Where they tend to (e.g., in immunochemistry) we do. For some tests, this can be justified by the standardization of methods to produce “equivalent” results, and sometimes by the many variables (method, reagent) that one could never hope to represent fully in a single name. However, even when we do distinguish these cases, we distinguish by type of method, not the most detailed possible method distinction. (See Section 2.7 – Type of Method, for more details.)

The College of American Pathologists produces statistical summaries of the results for measurements of standard samples broken down by laboratory and by instrument or procedure. (These are called CAP surveys.) We considered using this CAP survey data to decide empirically when test names should be distinguished by method, but decided this was not feasible because many of the apparent differences in method obtained with the standard samples were artifacts of the sample matrix and did not apply to serum specimens. In addition, the variation among laboratories was often of the same magnitude as the variation among methods within laboratories for the same method.

We do not mean to underrate the importance of method differences. The result message will still include information about the normal range for that particular test, the source laboratory and, if the laboratory wishes, specific information about the method. However, such information is reported in separate fields in the HL7 message (e.g., OBX-17 can carry very detailed method information). It is not embedded in the name of the test.