107160-4
Phase angle Xc/R [Ratio] Bioelectrical impedance analysis
Active
Term Description
Phase angel (PhA) is obtained as a ratio between the raw measures resistance (R) and reactance (Xc) from bioelectrical impedance analysis (BIA). PhA has been considered a predictor of disease severity in clinical conditions, such as malnutrition and increased nutritional risk
Part Description
LP190312-1 BIA
Bioelectrical impedance analysis (BIA) is a method for assessing body composition in patients. BIA measures the flow of an electric current through body tissues which can then be used to determine the total body water (TBW), fat mass (FM), fat-free mass (FFM), and fat mass percentage. Many BIA equations are available in the literature for estimating FFM. They varying in terms of the parameters included in multiple regression equations and in their applicability to individuals with different clinical presentations.[Mialich et. al. (2014). IJCN, 2(1), 1-10]
Source: Regenstrief LOINC
LOINC Names Get Info
- Fully-Specified Name
- Phase angle Xc/R:
Ratio: Pt: ^Patient: Qn: BIA - Long Common Name
- Phase angle Xc/R [Ratio] Bioelectrical impedance analysis
- Short Name
- Phase angle Xc/R BIA
Part Model Get Info
- Component
- Phase angle Xc/R
LP445927-9
- Analyte
- Phase angle Xc/R
LP445927-9
- Component Numerator
- Phase angle Xc
LP446845-2
- Component Numerator Core
- Phase angle Xc
LP446845-2
- Component Numerator Core Suffix
- NULL
- Component Denominator
- R
LP446846-0
- Component Denominator Core
- R
LP446846-0
- Component Denominator Core Suffix
- NULL
- Challenge
- NULL
- Adjustment
- NULL
- Count
- NULL
- Property
- Ratio
LP6852-0
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- ^Patient
LP310005-6
- System Core
- NULL
- Super System
- Patient
LP6985-8
- Scale
- Qn
LP7753-9
- Method
- BIA
LP190312-1
Basic Attributes
- Class
- NUTRITION&DIETETICS
- Type
- Clinical
- First Released
- Version 2.81
- Last Updated
- Version 2.81 (ADD)
- Order vs. Observation
- Observation
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| it-IT | Italian (Italy) | Angolo di fase Xc/D: Synonyms: Analisi bioimpedenziometrica Destro Nutrizione e Dietetica paziente Punto nel tempo (episodio) Reattanza |
| zh-CN | Chinese (China) | 相位角 Xc/R: Synonyms: Xc 相位角; |
Example Units
| Unit | Source |
|---|---|
| % | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://