Part Descriptions

LP33382-0   Guidance for angioplasty
Angioplasty is the mechanical alteration of a narrowed or totally obstructed vascular lumen, generally caused by atheroma (the lesion of atherosclerosis). The term derives from the roots Angio or vessel and plasticos fit for molding. The term has come to include all manner of vascular interventions typically performed in a minimally invasive or percutaneous method. See also Sheldoectomy Most commonly, the Seldinger technique is used to cannulate a blood vessel for access. A guiding catheter is introduced into the arterial (or venous) system and advanced through the system to the location of an obstruction. This in turn is followed by introduction of a guidewire which is advanced though the guide catheter, through the obstruction and extended into the blood vessel lumen beyond the obstruction. Over the guidewire, a balloon catheter is advanced through both the guide catheter and the obstruction. Copyright Text is available under the Creative Commons Attribution/Share-Alike License. See http://creativecommons.org/licenses/by-sa/3.0/ for details. Source: Wikipedia, Angioplasty (Wikipedia)

LP33382-0   Guidance for angioplasty
Endovascular reconstruction of an artery, which may include the removal of atheromatous plaque and/or the endothelial lining as well as simple dilatation. These are procedures performed by catheterization. When reconstruction of an artery is performed surgically, it is called ENDARTERECTOMY. Source: National Library of Medicine, MeSH 2006

LOINC Names Get Info

Fully-Specified Name
Guidance for angioplasty^W contrast IA:Find:Pt:Lower extremity.bilateral>Tibioperoneal arteries:Doc:RF.angio
Long Common Name
RFA Guidance for angioplasty of Tibioperoneal arteries - bilateral-- W contrast IA
Short Name
RFA Guided Tibioper aa-Bl Ang W contr IA

Part Model Get Info

  • Component
    Guidance for angioplasty^W contrast IA
    LP309061-2
    • Analyte
      Guidance for angioplasty
      LP33382-0
      • Component Numerator
        Guidance for angioplasty
        LP33382-0
        • Component Numerator Core
          Guidance for angioplasty
          LP33382-0
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      W contrast IA
      LP33384-6
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Find
    LP6813-2
  • Time
    Pt
    LP6960-1
  • System
    Lower extremity.bilateral>Tibioperoneal arteries
    LP36638-2
    • System Core
      Lower extremity.bilateral>Tibioperoneal arteries
      LP36638-2
    • Super System
      NULL
       
  • Scale
    Doc
    LP32888-7
  • Method
    RF.angio
    LP220469-3

Associated Observations

81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Releases 2.0 & 2.1.

LOINCNameR/O/CCardinalityExample UCUM Units
81220-6Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections
Indent11329-0History generalO
Indent55115-0Request (Radiology)O
Indent55111-9Current imaging procedure descriptions DocumentO
Indent55114-3Prior procedure descriptionsO
Indent18834-2Radiology Comparison study - observationO
Indent18782-3Radiology Study observation (findings)R
Indent19005-8Radiology - ImpressionO
Indent18783-1Radiology Study recommendationO
Indent55110-1ConclusionsO
Indent55107-7AddendumO
Indent18785-6Radiology Reason for studyO
Indent55108-5Patient presentationO
Indent55109-3ComplicationsO
Indent55112-7SummaryO
Indent55113-5Key imagesO

72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on the HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Release 1.1.

LOINCNameR/O/CCardinalityExample UCUM Units
72230-6Diagnostic imaging report - recommended C-CDA R1.1 sections
Indent18782-3Radiology Study observation (findings)R
Indent55107-7AddendumO
Indent55108-5Patient presentationO
Indent55109-3ComplicationsO
Indent55110-1ConclusionsO
Indent55111-9Current imaging procedure descriptions DocumentO
Indent11329-0History generalO
Indent55113-5Key imagesO
Indent55114-3Prior procedure descriptionsO
Indent19005-8Radiology - ImpressionO
Indent18834-2Radiology Comparison study - observationO
Indent18785-6Radiology Reason for studyO
Indent18783-1Radiology Study recommendationO
Indent55115-0Request (Radiology)O
Indent55112-7SummaryO

Basic Attributes

Class
RAD
Type
Clinical
First Released
Version 2.17
Last Updated
Version 2.64 (MIN)
Change Reason
The scale has been changed from "Nar" to "Doc" to fit with the CDA model.; Method of "XR.fluor.angio" was changed to "RF.angio". The LOINC/RadLex Committee agreed to use a subset of the two-letter DICOM modality codes as the primary modality identifier.; Changed System from "Tibioperoneal arteries.bilateral" based on the LOINC/Radlex unified model.;updated component from "angioplasty^W contrast IA' based on LOINC/Radlex unified model
Order vs. Observation
Both
HL7® Attachment Structure
Implementation guide exists

Member of these Groups Get Info

LOINC GroupGroup Name
LG41849-7Region imaged: Lower extremity
LG38378-2RF.angio|Tibioperoneal arteries|Guidance for angioplasty^W contrast IA|Laterality:ANY

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Οδηγίες για αγγειοπλαστική^Με σκιαγραφικό ενδοαρτηριακώς:Εύρεση:Pt:Κάτω άκρο.αμφοτερόπλεuρα>Κνημοπερονιαίες αρτηρίες:Doc:RF.angio
Synonyms: Doc Pt RAD RF RF.angio Άκρο Άκρο.αμφοτερόπλεuρα Εύρεση Κάτω άκρο Κάτω άκρο.αμφοτερόπλεuρα Κάτω άκρο.αμφοτερόπλεuρα>Κνημοπερονιαίες αρτηρίες Με σκιαγραφικό Με σκιαγραφικό ενδοαρτηριακώς Οδηγίες Οδηγίες για αγγειοπλαστική
es-MXSpanish (Mexico)Guía para angioplastia ^ W contraste IA:Tipo:Punto temporal:Extremidad inferior bilateral> arterias tibioperoneales:Documento:RF.angio
it-ITItalian (Italy)Angioplastica^Con contrasto intra arterioso:Osservazione:Pt:Estremità inferiore.bilaterale>Arterie tibioperoneali:Doc:RF.angio
Synonyms: Arterie tibioperoneali Bilaterali Estremità Bilaterale Estremità inferiore Bilaterale Osservazione Punto nel tempo (episodio) Radio-fluoroscopia Radio-fluoroscopia Angiografia Radiologia
pt-BRPortuguese (Brazil)Angioplastia^com contraste IA:Achado:Pt:Artérias tibiofibulares.bilateral:Nar:Radioscopia.angiografia
Synonyms: ; Angpsty; Angplsty; W contr IA; WC; Finding; Findings; Point in time; Random; Tibioperon aa-BL; Tibioperon aa-BL; Narrative; Report; XRA; Angiogram; Ang; Angm; Flr; Fluoro; Fluoroscopy; Xray; X-ray; Plain Films; c; Contrst; Contr; Contra; RADIOLOGY; Imaging; Arteriogram
zh-CNChinese (China)旨在血管成形术的引导^采用动脉注射对比剂:发现:时间点:下肢.双侧>胫腓动脉类:文档型:放射荧光透视法.血管造影术
Synonyms: RF;放射荧光透视;放射线荧光透视法;放射线荧光透视;透视摄影;无线荧光透视法;无线荧光透视 下 下的 下肢(腿、腿部).双侧(两侧、两边);双下肢;双侧下肢;双腿 下部 两侧 两侧的 临床文档型;临床文档;文档;文书;医疗文书;临床医疗文书 低级 低级的 制导 动脉X光照片 动脉像 动脉血管造影 动脉血管造影术 动脉血管造影照片 动脉造影 动脉造影术 动脉造影照片 双 双侧的 发现是一个原子型临床观察指标,并不是作为印象的概括陈述。体格检查、病史、系统检查及其他此类观察指标的属性均为发现。它们的标尺对于编码型发现可能是名义型,而对于叙述型文本之中所报告的发现,则可能是叙述型。;发现物;所见;结果;结论 增强剂 对比剂动脉血管造影 对比剂动脉血管造影术 对比剂动脉造影 对比剂动脉造影术 对比剂多动脉血管造影 对比剂多动脉血管造影术 对比剂多动脉造影 对比剂多动脉造影术 对比增强剂 导向 成像;放射医学;放射学;显像 指导 指引 放射荧光透视法(RF、放射荧光透视、放射线荧光透视法、放射线荧光透视、透视摄影、无线荧光透视法、无线荧光透视).血管造影术(血管造影、血管照相术、血管照相、血管学、血管摄影、血管摄影术) 时刻;随机;随意;瞬间 肢;四肢 肢体(肢、四肢).双侧(两侧、两边);双侧肢体 胫腓动脉类.双侧;双侧胫腓动脉类;双侧胫腓动脉;下肢(腿、腿部).双侧>胫腓动脉类(胫腓动脉) 腿;腿部 血管重建术;旨在(针对、用于)血管成形术(血管重建术、血管成型术、血管整形术、血管扩张术、扩张术、血管成形、血管成型、血管扩张)的引导 较低 较低的 采用动脉注射对比剂 血管造影 采用增强剂;采用对比增强剂 采用对比剂 IA 血管造影 采用对比剂 IA 血管造影术 采用对比剂 IA;采用动脉注射增强剂 采用对比剂 多动脉 血管造影

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=43794-7