60924-8
Carbon dioxide [VFr/PPres] in Airway adaptor --during inspiration
Active
Term Description
The IEEE 11073 Standards Committee does not distinguish between measures of gas concentration reported as partial pressure and volume percent because they can be converted from one to the other under the law of gases. To make it clear that these could be reported either way, LOINC presents the property for these terms as both a volume fraction and a partial pressure (VFr/PPres), with corresponding units of %{vol} and mm[Hg], respectively.
Part Description
LP15150-3 Carbon dioxide
CO2 content is a measurement of total CO2 in the blood. Most of it is in the form of bicarbonate (HCO3) controlled by the kidney. A small amount (5%) of CO2 is dissolved in the blood as insoluble carbonic acid (H2CO3). Changes in CO2 content generally relate to metabolic issues, renal function and unusual losses (diarrhea). Respiratory disease can ultimately effect CO2 content, but only slightly and only if prolonged. (Operational Medicine 2001, Arterial Blood Gas, Brookside Associates Medical Education Division)
Source: Regenstrief Institute
LOINC Names Get Info
- Fully-Specified Name
- Carbon dioxide^during inspiration:
VFr/PPres: Pt: Airway adaptor: Qn: - Long Common Name
- Carbon dioxide [VFr/PPres] in Airway adaptor --during inspiration
- Short Name
- CO2 during insp VFr/PPres Away adap
Part Model Get Info
- Component
- Carbon dioxide^during inspiration
LP308227-0
- Analyte
- Carbon dioxide
LP15150-3
- Challenge
- during inspiration
LP101881-3
- Adjustment
- NULL
- Count
- NULL
- Property
- VFr/PPres
LP186992-6
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- Airway adaptor
LP207647-1
- System Core
- Airway adaptor
LP207647-1
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- NULL
Basic Attributes
- Class
- PULM
- Type
- Clinical
- First Released
- Version 2.54
- Last Updated
- Version 2.70 (MIN)
- Change Reason
- Changed System from "Airway" to "Airway adaptor" to clarify meaning per IEEE 11073:10101a standard and to distinguish the "Airway adaptor" device from "Respiratory system.airway", which is the airway portion of the patient respiratory system.
- Order vs. Observation
- Both
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 75885-4 | IEEE 11073 Rosetta panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Διοξείδιο του άνθρακα^κατά την εισπνοή: Synonyms: Pt PULM Qn VFr/PPres Διοξείδιο του άνθρακα εισπνοή κατά την εισπνοή Προσαρμογέας αεραγωγού |
| es-MX | Spanish (Mexico) | Dióxido de carbono ^ durante la inspiración: |
| it-IT | Italian (Italy) | Diossido di carbonio^durante l'inspirazione: Synonyms: Biossido di carbonio Gestione ventilazione polmonare Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 二氧化碳^在吸气过程中: Synonyms: cCO2; |
Example Units
| Unit | Source |
|---|---|
| %{vol}; mm[Hg] | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://