Term Description

The time interval from the beginning of electrical stimulation of the ventricles to the opening of the aortic valve (electrical systole).

Part Description

LP187098-1   NI-ICG
Non-invasive impedance cardiography (ICG) applies a constant, low-amplitude, high-frequency, alternating electrical current to the thorax and measures the corresponding voltage to detect changes in thoracic impedance. The beat-to-beat changes in impedance are used to to measure both direct and derived variables, such as stroke volume, cardiac output, systemic vascular resistance, and velocity index. PMID: 14564142 Source: Regenstrief LOINC, PMID: 14564142

LOINC Names Get Info

Fully-Specified Name
Pre ejection time:Time:Pt:Heart.ventricle.left:Qn:NI-ICG
Long Common Name
Left ventricular Pre ejection Time
Short Name
LV Pre eject Time

Part Model Get Info

  • Component
    Pre ejection time
    LP73136-1
    • Analyte
      Pre ejection time
      LP73136-1
      • Component Numerator
        Pre ejection time
        LP73136-1
        • Component Numerator Core
          Pre ejection time
          LP73136-1
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Time
    LP6879-3
  • Time
    Pt
    LP6960-1
  • System
    Heart.ventricle.left
    LP7310-8
    • System Core
      Heart.ventricle.left
      LP7310-8
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    NI-ICG
    LP187098-1

Basic Attributes

Class
CARDIO-PULM
Type
Clinical
First Released
Version 2.54
Last Updated
Version 2.70 (MIN)
Order vs. Observation
Both

Member of these Panels

LOINCLong Common Name
75885-4IEEE 11073 Rosetta panel

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Χρόνος πριν από την εκτόξευση:Time:Pt:Καρδιά.κοιλία.αριστερή:Qn:NI-ICG
Synonyms: CARDIO-PULM NI-ICG Pt PULM Qn Time Καρδιά Καρδιά.κοιλία Καρδιά.κοιλία.αριστερή Χρόνος εξώθησης Χρόνος πριν από την εκτόξευση
es-MXSpanish (Mexico)Tiempo de pre eyección:Tiempo:Punto temporal:Corazón.ventrículo.izquierdo:Cuantitativo:NI-ICG
it-ITItalian (Italy)pre tempo di espulsione:Tempo:Pt:Cuore.ventricolo.sinistro:Qn:NI-ICG,Non-invasive impedance cardiography (ICG),cardiogr
Synonyms: Cardiopolmonare Gestione ventilazione polmonare prima di espulsione prima di tempo di espulsione Punto nel tempo (episodio) Tempo (e.g. secondi) Ventricolo cardiaco Ventricolo cardiaco Sinistro
zh-CNChinese (China)在射血时间之前:时间:时间点:心脏.心室.左侧:定量型:NI-ICG
Synonyms: L LT XXX刺激 - 在...之前 之前于射血 之前于射血期;在射血时间(喷射时间、发射时间、排血时间、排出时间、排出期、喷血时间、射血期)之前 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 向左 向左侧 喷射时间;发射时间;排血时间;排出时间;排出期;喷血时间;射血期 左 左侧(Left,LT,L) 左向 左心室;心.室.左侧;心.心室.左侧;心脏.室.左侧 左边 心 心.室;心.心室;心室;心脏.室 心肺;心肺机能 无创(非侵入性)阻抗心动描记术(心阻抗图、心阻抗血流图、阻抗心动图法、阻抗心动描记法、NI-ICG)Non-invasive impedance cardiography (NI-ICG) 时刻;随机;随意;瞬间 时间(如秒);时间(如秒数) 肺部测量指标与呼吸机管理

Example Units

UnitSource
msExample UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=60973-5