Term Description

The IEEE 11073 Standards Committee does not distinguish between measures of gas concentration reported as partial pressure and volume percent because they can be converted from one to the other under the law of gases. To make it clear that these could be reported either way, LOINC presents the property for these terms as both a volume fraction and a partial pressure (VFr/PPres), with corresponding units of %{vol} and mm[Hg], respectively.

Part Descriptions

LP18610-3   Enflurane
An extremely stable inhalation anesthetic that allows rapid adjustments of anesthesia depth with little change in pulse or respiratory rate. Source: National Library of Medicine, MeSH 2006

LP18610-3   Enflurane
Enflurane is a commonly used organic anesthetic. Used in combination with nitrous oxide, it is a very effective anesthetic. The dosage of Enflurane being administered is set and monitored throughout general anesthesia.
PMID: 571219 Source: Regenstrief LOINC

LOINC Names Get Info

Fully-Specified Name
Enflurane^during expiration:VFr/PPres:Pt:Airway adaptor:Qn:
Long Common Name
Enflurane [VFr/PPres] Airway adaptor --during expiration
Short Name
Enf during expir VFr/PPres Away adap

Part Model Get Info

  • Component
    Enflurane^during expiration
    LP308232-0
    • Analyte
      Enflurane
      LP18610-3
      • Component Numerator
        Enflurane
        LP18610-3
        • Component Numerator Core
          Enflurane
          LP18610-3
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      during expiration
      LP101880-5
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    VFr/PPres
    LP186992-6
  • Time
    Pt
    LP6960-1
  • System
    Airway adaptor
    LP207647-1
    • System Core
      Airway adaptor
      LP207647-1
    • Super System
      NULL
       
  • Scale
    Qn
    LP7753-9
  • Method
    NULL
     

Basic Attributes

Class
PULM
Type
Clinical
First Released
Version 2.56
Last Updated
Version 2.70 (MIN)
Order vs. Observation
Both

Member of these Panels

LOINCLong Common Name
75885-4IEEE 11073 Rosetta panel

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Ενφλουράνιο^κατά την εκπνοή:VFr/PPres:Pt:Προσαρμογέας αεραγωγού:Qn:
Synonyms: Pt PULM Qn VFr/PPres Εκπνοή Ενφλουράνιο κατά την εκπνοή Προσαρμογέας αεραγωγού
es-MXSpanish (Mexico)Enflurano ^ durante la expiración:VFr / PPres:Punto temporal:Adaptador de vías respiratorias:Cuantitativo:
it-ITItalian (Italy)Enflurano^durante l'espirazione:VFr/Ppres:Pt:Adattatore di via respiratoria:Qn:
Synonyms: Gestione ventilazione polmonare Punto nel tempo (episodio)
zh-CNChinese (China)安氟醚^在呼气过程中:体积分数/分压:时间点:气道连接器:定量型:
Synonyms: 可用数量表示的;定量性;数值型;数量型;连续数值型标尺 吐气 呼 呼出 呼出;呼出气体 在呼气期间;呼气过程中;呼气期间 容积分数/分压;体积(容积)分数/分压(分压力、分压强、局部压力、气体分压、部分压力) 恩氟烷;氟甲氧氟烷;安氟烷;氨氟醚;易使宁 时刻;随机;随意;瞬间 气道接头;气道适配器;气道接合器 肺部测量指标与呼吸机管理

Example Units

UnitSource
%{vol}; mm[Hg]Example UCUM Units

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=61019-6