66758-4
Clot firmness reduction [Length fraction] in Blood by Thromboelastography --60M post maximum clot amplitude
Active
Part Description
LP69276-1 Thromboelastography
Thromboelastography (TEG) is a viscoelastic test of hemostasis. In TEG, whole blood is added to a cup in which a pin is suspended, the cup is rotated, and as the clot forms, the rotational force is transferred to the pin. The torsion of the pin is transformed into a graphic record of the physical shape of a clot during fibrin formation and lysis. TEG can provide information about the status of coagulation factors, platelet function and fibrinolysis in whole blood. TEG is primarily used for assessment of hemostasis after cardiopulmonary bypass, during liver transplant surgery, or hemorrhaging episodes. TEG parameters are also used as part of the guiding algorithms for plasma, platelet and cryoprecipitate transfusions.
Copyright Copyright © 1995-2009
Source: Mayo Medical Laboratories
LOINC Names Get Info
- Fully-Specified Name
- Clot firmness reduction^60M post maximum clot amplitude:
LenFr: Pt: Bld: Qn: Thromboelastography - Long Common Name
- Clot firmness reduction [Length fraction] in Blood by Thromboelastography --60M post maximum clot amplitude
- Short Name
- CF reduc 60M p MA LenFr Bld TEG
- Display Name
- Clot firmness reduction 60 Min post maximum clot amplitude TEG (Bld) [Length fraction]
- Consumer Name Alpha Get Info
- Clot firmness reduction 60 min after max clot amplitude, Blood
Part Model Get Info
- Component
- Clot firmness reduction^60M post maximum clot amplitude
LP307617-3
- Analyte
- Clot firmness reduction
LP129070-1
- Component Numerator
- Clot firmness reduction
LP129070-1
- Component Numerator Core
- Clot firmness reduction
LP129070-1
- Component Numerator Core Suffix
- NULL
- Component Denominator
- NULL
- Component Denominator Core
- NULL
- Component Denominator Core Suffix
- NULL
- Challenge
- 60M post maximum clot amplitude
LP129071-9
- Adjustment
- NULL
- Count
- NULL
- Property
- LenFr
LP6823-1
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- Bld
LP7057-5
- System Core
- Bld
LP7057-5
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- Thromboelastography
LP69276-1
Basic Attributes
- Class
- COAG
- Type
- Laboratory
- First Released
- Version 2.38
- Last Updated
- Version 2.70 (MIN)
- Order vs. Observation
- Observation
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| cs-CZ | Czech (Czechia) | Sraženina snížení pevnosti^60 minut po dosažení maximální amplitudy sraženiny: |
| el-GR | Greek (Greece) | Μείωση της σταθερότητας του θρόμβου^60 λεπτά μετά το μέγιστο εύρος θρόμβου: Synonyms: 60 λεπτά μετά το μέγιστο εύρος θρόμβου COAG LenFr Pt Qn Αίμα Θρομβοελαστογραφία Θρόμβος Μείωση της σταθερότητας του θρόμβου Σταθερότητα Σταθερότητα θρόμβου |
| es-ES | Spanish (Spain) | Reduccion de la firmeza del coágulo^60M después de amplitud maxima del coágulo: Synonyms: Cuantitativo |
| es-MX | Spanish (Mexico) | Reducción de la firmeza del coágulo ^60 M después de la amplitud máxima del coágulo: |
| fr-FR | French (France) | Caillot réduction de la fermeté^T60min après amplitude maximale du caillot: |
| it-IT | Italian (Italy) | Riduzione fermezza coagulo^60Minuti post massima ampiezza coagulo: Synonyms: 60 minuti dopo massima ampiezza del coagulo Compattezza Fermezza del coagulo Frazione di lunghezza Punto nel tempo (episodio) Riduzione della fermezza del coagulo Sangue Studio di coagulazione TEG |
| nl-NL | Dutch (Netherlands) | stolselstevigheid afname^60 minuten na maximum stollingsamplitude: Synonyms: 60M na maximum stollingsamplitude coagulatiemethode |
| pl-PL | Polish (Poland) | Zmniejszenie spoistości skrzepu^60min po maksimum amplitudy skrzepu: Synonyms: 60 minut po maksimum amplitudy skrzepu Redukcja spójności skrzepu po 60M od maksymalnej amplitudy |
| tr-TR | Turkish (Turkey) | Pıhtı sertliğinin azaltılması^60dk maksimum pıhtı büyüklüğü: |
| zh-CN | Chinese (China) | 凝块稳固性降低^在达到最大凝固幅度之后60分钟: Synonyms: XXX刺激 - 在...之后 之后于... 凝块稳固性下降; |
Example Units
| Unit | Source |
|---|---|
| % | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
LOINC Copyright
Copyright © Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://