75936-5
Nitrogen dioxide [VFr/PPres] Airway adaptor --during inspiration
Active
Term Description
The IEEE 11073 Standards Committee does not distinguish between measures of gas concentration reported as partial pressure and volume percent because they can be converted from one to the other under the law of gases. To make it clear that these could be reported either way, LOINC presents the property for these terms as both a volume fraction and a partial pressure (VFr/PPres), with corresponding units of %{vol} and mm[Hg], respectively.
Part Description
LP186951-2 Nitrogen dioxide
Nitrogen dioxide (NO2) is a potentially toxic gas formed from nitrous oxide (NO) in the presence of oxygen (O2). For patients who are on a mechanical ventilator, the amount of NO2 produced in the ventilator circuit is directly proportional to the concentration of NO and O2 and inversely proportional to minute ventilation and total gas flow. NO2 monitors detect the amount of NO2 present in the circuit. PMID: 9142588
Source: Regenstrief LOINC,
PMID: 9142588
LOINC Names Get Info
- Fully-Specified Name
- Nitrogen dioxide^during inspiration:
VFr/PPres: Pt: Airway adaptor: Qn: - Long Common Name
- Nitrogen dioxide [VFr/PPres] Airway adaptor --during inspiration
- Short Name
- NO2 during insp VFr/PPres Away adap
Part Model Get Info
- Component
- Nitrogen dioxide^during inspiration
LP308885-5
- Analyte
- Nitrogen dioxide
LP186951-2
- Component Numerator
- Nitrogen dioxide
LP186951-2
- Component Numerator Core
- Nitrogen dioxide
LP186951-2
- Component Numerator Core Suffix
- NULL
- Component Denominator
- NULL
- Component Denominator Core
- NULL
- Component Denominator Core Suffix
- NULL
- Challenge
- during inspiration
LP101881-3
- Adjustment
- NULL
- Count
- NULL
- Property
- VFr/PPres
LP186992-6
- Time
- Pt
LP6960-1
- Time Core
- Pt
LP6960-1
- Time Modifier
- NULL
- System
- Airway adaptor
LP207647-1
- System Core
- Airway adaptor
LP207647-1
- Super System
- NULL
- Scale
- Qn
LP7753-9
- Method
- NULL
Basic Attributes
- Class
- PULM
- Type
- Clinical
- First Released
- Version 2.56
- Last Updated
- Version 2.56 (MAJ)
- Order vs. Observation
- Both
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 75885-4 | IEEE 11073 Rosetta panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Διοξείδιο του αζώτου^κατά την εισπνοή: Synonyms: Pt PULM Qn VFr/PPres Άζωτο Διοξείδιο του αζώτου εισπνοή κατά την εισπνοή Προσαρμογέας αεραγωγού |
| es-MX | Spanish (Mexico) | Dióxido de nitrógeno ^ durante la inspiración: |
| it-IT | Italian (Italy) | Biossido di azoto^durante l'inspirazione: Synonyms: Gestione ventilazione polmonare Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 二氧化氮^在吸气过程中: Synonyms: In N; |
Example Units
| Unit | Source |
|---|---|
| %{vol}; mm[Hg] | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info