Part Description

LP6617-7   US.doppler
Doppler ultrasound detects the shift in frequency of ultrasound signals reflected from moving objects. Conventional Doppler techniques assess the velocity of blood flow by measuring high-frequency, low-amplitude signals from small, fast-moving blood cells. PMID: 16534017 Source: Regenstrief LOINC, PMID: 16534017

Fully-Specified Name

Component
Multisection limited
Property
Find
Time
Pt
System
Head
Scale
Doc
Method
US.doppler

Additional Names

Short Name
DOP Head Ltd

Associated Observations

81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Releases 2.0 & 2.1.

LOINC Name R/O/C Cardinality Example UCUM Units
81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections
Indent11329-0 History general O
Indent55115-0 Request (Radiology) O
Indent55111-9 Current imaging procedure descriptions Document O
Indent55114-3 Prior procedure descriptions O
Indent18834-2 Radiology Comparison study - observation O
Indent18782-3 Radiology Study observation (findings) R
Indent19005-8 Radiology - Impression O
Indent18783-1 Radiology Study recommendation O
Indent55110-1 Conclusions O
Indent55107-7 Addendum O
Indent18785-6 Radiology Reason for study O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55112-7 Summary O
Indent55113-5 Key images O

72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on the HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Release 1.1.

LOINC Name R/O/C Cardinality Example UCUM Units
72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections
Indent18782-3 Radiology Study observation (findings) R
Indent55107-7 Addendum O
Indent55108-5 Patient presentation O
Indent55109-3 Complications O
Indent55110-1 Conclusions O
Indent55111-9 Current imaging procedure descriptions Document O
Indent11329-0 History general O
Indent55113-5 Key images O
Indent55114-3 Prior procedure descriptions O
Indent19005-8 Radiology - Impression O
Indent18834-2 Radiology Comparison study - observation O
Indent18785-6 Radiology Reason for study O
Indent18783-1 Radiology Study recommendation O
Indent55115-0 Request (Radiology) O
Indent55112-7 Summary O

Basic Attributes

Class
RAD
Type
Clinical
First Released
Version 2.56
Last Updated
Version 2.61
Order vs. Observation
Both
HL7® Attachment Structure
Implementation guide exists

Member of these Groups Get Info

LOINC Group Group Name
LG41824-0 Region imaged: Head

Language Variants Get Info

Tag Language Translation
es-MX Spanish (Mexico) Multisección limitada:Tipo:Punto temporal:Cabeza:Documento:US.doppler
it-IT Italian (Italy) Sezioni multiple limitata:Osservazione:Pt:Testa:Doc:Eco.doppler
Synonyms: Eco Ecografia.doppler Multistrato Multistrato limitata Osservazione Punto nel tempo (episodio) Radiologia
zh-CN Chinese (China) 局部多层:发现:时间点:头部:文档型:超声.多普勒
Synonyms: (多层(多平面、多切面、多断面、多截面、多剖面、多排) 一种超声检查,用于确定几个脑部结构的位置和大小,从而系统地检查脑部和脊髓可疑的软组织疾病。 临床文档型;临床文档;文档;文书;医疗文书;临床医疗文书 发现是一个原子型临床观察指标,并不是作为印象的概括陈述。体格检查、病史、系统检查及其他此类观察指标的属性均为发现。它们的标尺对于编码型发现可能是名义型,而对于叙述型文本之中所报告的发现,则可能是叙述型。;发现物;所见;结果;结论 受限 受限的 多层(多平面、多切面、多断面、多截面、多剖面、多排);多排 多层局部;多层有限;局部多层(多平面、多切面、多断面、多截面、多剖面、多排);有限多层;局限多层;多层局部(局部多层、多层有限、有限多层、局限多层) 大脑;头;头壳;头的;头盖;头盖的;头盖骨;头部的;头颅;头颅内;头颅内的;头骨;脑;脑壳;脑的;颅;颅侧;颅的;颅骨;颅骨内;颅骨内的 头部超声检查方法 头部超声波 头部超声波检查方法 局部的 心脏超声.多普勒 成像;放射医学;放射学;显像 时刻;随机;随意;瞬间 有界的 有限 有限的 脑回波图 脑回波描记仪 脑回波描记仪术 被限制的 超声检查方法;超声检查法;超声波;超声波检查方法;超声波检查法 限制的

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=80856-8