Part Description

LP262710-9   {Imaging modality}
{Imaging modality} is used for image-guided procedures, where the particular type of imaging used is not specified in the orderable. For example, liver biopsies may be performed under ultrasound or CT guidance, and the particular modality used may be at the discretion of the operator. In such cases, {Imaging modality} indicates imaging guidance not further specified. This concept corresponds to the RP (radiology procedure) concept used in RSNA's RadLex Playbook. Source: Regenstrief LOINC

LOINC Names Get Info

Fully-Specified Name
Guidance additional for placement of stent:Find:Pt:Lower extremity>Lower leg vessel:Doc:{Imaging modality}
Long Common Name
Guidance for additional placement of stent of Lower leg vessel
Short Name
Guided Lower leg ves Stent place addl

Part Model Get Info

  • Component
    Guidance additional for placement of stent
    LP262724-0
    • Analyte
      Guidance additional for placement of stent
      LP262724-0
      • Component Numerator
        Guidance additional for placement of stent
        LP262724-0
        • Component Numerator Core
          Guidance additional for placement of stent
          LP262724-0
        • Component Numerator Core Suffix
          NULL
           
      • Component Denominator
        NULL
         
        • Component Denominator Core
          NULL
           
        • Component Denominator Core Suffix
          NULL
           
    • Challenge
      NULL
       
    • Adjustment
      NULL
       
    • Count
      NULL
       
  • Property
    Find
    LP6813-2
  • Time
    Pt
    LP6960-1
  • System
    Lower extremity>Lower leg vessel
    LP262727-3
    • System Core
      Lower extremity>Lower leg vessel
      LP262727-3
    • Super System
      NULL
       
  • Scale
    Doc
    LP32888-7
  • Method
    {Imaging modality}
    LP262710-9

Associated Observations

81220-6 Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Releases 2.0 & 2.1.

LOINCNameR/O/CCardinalityExample UCUM Units
81220-6Diagnostic imaging report - recommended C-CDA R2.0 and R2.1 sections
Indent11329-0History generalO
Indent55115-0Request (Radiology)O
Indent55111-9Current imaging procedure descriptions DocumentO
Indent55114-3Prior procedure descriptionsO
Indent18834-2Radiology Comparison study - observationO
Indent18782-3Radiology Study observation (findings)R
Indent19005-8Radiology - ImpressionO
Indent18783-1Radiology Study recommendationO
Indent55110-1ConclusionsO
Indent55107-7AddendumO
Indent18785-6Radiology Reason for studyO
Indent55108-5Patient presentationO
Indent55109-3ComplicationsO
Indent55112-7SummaryO
Indent55113-5Key imagesO

72230-6 Diagnostic imaging report - recommended C-CDA R1.1 sections

This panel contains the recommended sections for diagnostic imaging reports based on the HL7 Implementation Guide for CDA® Release 2: Consolidated CDA Templates for Clinical Notes (US Realm) DSTU Release 1.1.

LOINCNameR/O/CCardinalityExample UCUM Units
72230-6Diagnostic imaging report - recommended C-CDA R1.1 sections
Indent18782-3Radiology Study observation (findings)R
Indent55107-7AddendumO
Indent55108-5Patient presentationO
Indent55109-3ComplicationsO
Indent55110-1ConclusionsO
Indent55111-9Current imaging procedure descriptions DocumentO
Indent11329-0History generalO
Indent55113-5Key imagesO
Indent55114-3Prior procedure descriptionsO
Indent19005-8Radiology - ImpressionO
Indent18834-2Radiology Comparison study - observationO
Indent18785-6Radiology Reason for studyO
Indent18783-1Radiology Study recommendationO
Indent55115-0Request (Radiology)O
Indent55112-7SummaryO

Basic Attributes

Class
RAD
Type
Clinical
First Released
Version 2.63
Last Updated
Version 2.64 (MIN)
Order vs. Observation
Both
HL7® Attachment Structure
Implementation guide exists

Member of these Groups Get Info

LOINC GroupGroup Name
LG41849-7Region imaged: Lower extremity

Language Variants Get Info

TagLanguageTranslation
el-GRGreek (Greece)Πρόσθετες οδηγίες για τοποθέτηση ενδοπρόθεσης:Εύρεση:Pt:Κάτω άκρο>Αγγείο κνήμης:Doc:{Μέθοδος απεικόνισης}
Synonyms: {Μέθοδος απεικόνισης} Doc Pt RAD Άκρο Απεικόνιση Εύρεση Κάτω άκρο Κάτω άκρο>Αγγείο κνήμης Κάτω άκρο>Κνήμη Κνήμη Οδηγίες Πρόσθετες οδηγίες για τοποθέτηση ενδοπρόθεσης
es-MXSpanish (Mexico)Orientación adicional para la colocación de un stent:Tipo:Punto temporal:Extremidad inferior> Vaso de la pierna:Documento:{Imaging modality}
it-ITItalian (Italy)Linee guida aggiuntive per posizionamento di stent:Osservazione:Pt:Estremità inferiore>Vaso della parte inferiore della gamba:Doc:{Modalità imaging}
Synonyms: {Modalità diagnostica per immagini} Osservazione Parte inferiore della gamba Punto nel tempo (episodio) Raccomandazioni cliniche aggiuntive per posizionamento di stent Radiologia Vaso della parte inferiore della gamba
zh-CNChinese (China)旨在额外置入支架的引导:发现:时间点:下肢>小腿血管:文档型:{成像方式}
Synonyms: {成像(显象、影像学、扫描)方式(模态、模式、设备)};成像方式;成像模态;显象方式;成像模式;成像设备;显像模式 下 下的 下肢(腿、腿部)>小腿 下肢(腿、腿部)>小腿血管(脉管) 下部 临床文档型;临床文档;文档;文书;医疗文书;临床医疗文书 低级 低级的 制导 发现是一个原子型临床观察指标,并不是作为印象的概括陈述。体格检查、病史、系统检查及其他此类观察指标的属性均为发现。它们的标尺对于编码型发现可能是名义型,而对于叙述型文本之中所报告的发现,则可能是叙述型。;发现物;所见;结果;结论 外辅骨;小腿肚;排骨;胫;胫骨;腓;腓肠;腿肚子;辅骨;骸 导向 成像;放射医学;放射学;显像 成象;成象技术;影像学;显像;透视显像 指导 指引 旨在(针对、用于)额外(附加、另外、其他)置入(安置、放置、摆位、安排)支架的引导;旨在额外支架置入(置入术)的引导 时刻;随机;随意;瞬间 肢;四肢 脉管 腿;腿部 较低 较低的 附加的 额外 额外的

LOINC Terminology Service (API) using HL7® FHIR® Get Info

CodeSystem lookup
https://fhir.loinc.org/CodeSystem/$lookup?system=http://loinc.org&code=87140-0