96227-4
Multifocal electroretinography (mfERG) panel
Active
96229-0 Right macula N1 amplitude--light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420845-2 N1 amplitude
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- N1 amplitude^light-adapted
- Property
- Elpot
- Time
- Pt
- System
- Macula.right
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Εύρος N1^προσαρμογή στο φως: Synonyms: Elpot EYE EYE.ERG Pt Qn Εύρος N1 Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Ωχρά κηλίδα Ωχρά κηλίδα.δεξιά |
| es-MX | Spanish (Mexico) | Amplitud N1^ adaptado a la luz: |
| it-IT | Italian (Italy) | N1, ampiezza^adattato alla luce: Synonyms: Ampiezza N1 Elettroretinogramma Macula destra Mediante ERG mfERG Occhio Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | N1 波振幅^明适应型: Synonyms: N1 波振幅(波幅、 |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
96228-2 Left macula N1 amplitude--light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420845-2 N1 amplitude
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- N1 amplitude ^light-adapted
- Property
- Elpot
- Time
- Pt
- System
- Macula.left
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Εύρος N1^προσαρμογή στο φως: Synonyms: Elpot EYE EYE.ERG Pt Qn Εύρος N1 Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Ωχρά κηλίδα Ωχρά κηλίδα.αριστερά |
| es-MX | Spanish (Mexico) | Amplitud N1^ adaptado a la luz: |
| it-IT | Italian (Italy) | N1, ampiezza^adattato alla luce: Synonyms: Ampiezza N1 Elettroretinogramma Macula sinistra Mediante ERG mfERG Occhio Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | N1 波振幅^明适应型: Synonyms: L LT N1 波振幅(波幅、 |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
96230-8 Right macula N1 implicit time --light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420849-4 N1 implicit time
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- N1 implicit time^light-adapted
- Property
- Time
- Time
- Pt
- System
- Macula.right
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Χρόνος μέγιστης Ν1^προσαρμογή στο φως: Synonyms: EYE EYE.ERG Pt Qn Time Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Χρόνος μέγιστης Ν1 Ωχρά κηλίδα Ωχρά κηλίδα.δεξιά |
| es-MX | Spanish (Mexico) | N1 tiempo implícito^ adaptado a la luz: |
| it-IT | Italian (Italy) | N1, tempo implicito^adattato alla luce: Synonyms: Elettroretinogramma Macula destra Mediante ERG mfERG Occhio Punto nel tempo (episodio) Tempo (e.g. secondi) Tempo implicito N1 |
| zh-CN | Chinese (China) | N1 波潜伏时间^明适应型: Synonyms: N1 波潜伏时间(潜伏期、 |
Example Units
| Unit | Source |
|---|---|
| ms | Example UCUM Units |
96231-6 Left macula N1 implicit time --light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420849-4 N1 implicit time
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- N1 implicit time^light-adapted
- Property
- Time
- Time
- Pt
- System
- Macula.left
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Χρόνος μέγιστης Ν1^προσαρμογή στο φως: Synonyms: EYE EYE.ERG Pt Qn Time Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Χρόνος μέγιστης Ν1 Ωχρά κηλίδα Ωχρά κηλίδα.αριστερά |
| es-MX | Spanish (Mexico) | N1 tiempo implícito^ adaptado a la luz: |
| it-IT | Italian (Italy) | N1, tempo implicito^adattato alla luce: Synonyms: Elettroretinogramma Macula sinistra Mediante ERG mfERG Occhio Punto nel tempo (episodio) Tempo (e.g. secondi) Tempo implicito N1 |
| zh-CN | Chinese (China) | N1 波潜伏时间^明适应型: Synonyms: L LT N1 波潜伏时间(潜伏期、 |
Example Units
| Unit | Source |
|---|---|
| ms | Example UCUM Units |
96238-1 Right macula P1 amplitude--light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420847-8 P1 amplitude
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- P1 amplitude^light-adapted
- Property
- Elpot
- Time
- Pt
- System
- Macula.right
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Εύρος P1^προσαρμογή στο φως: Synonyms: Elpot EYE EYE.ERG P1 Pt Qn Εύρος P1 Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Ωχρά κηλίδα Ωχρά κηλίδα.δεξιά |
| es-MX | Spanish (Mexico) | Amplitud P1^ adaptado a la luz: |
| it-IT | Italian (Italy) | P1, ampiezza^adattato alla luce: Synonyms: Ampiezza P1 Elettroretinogramma Macula destra Mediante ERG mfERG Occhio Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | P1 波振幅^明适应型: Synonyms: P1 型 P1 波振幅(波幅、 |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
96239-9 Left macula P1 amplitude--light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420847-8 P1 amplitude
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- P1 amplitude^light-adapted
- Property
- Elpot
- Time
- Pt
- System
- Macula.left
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Εύρος P1^προσαρμογή στο φως: Synonyms: Elpot EYE EYE.ERG P1 Pt Qn Εύρος P1 Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Ωχρά κηλίδα Ωχρά κηλίδα.αριστερά |
| es-MX | Spanish (Mexico) | Amplitud P1^ adaptado a la luz: |
| it-IT | Italian (Italy) | P1, ampiezza^adattato alla luce: Synonyms: Ampiezza P1 Elettroretinogramma Macula sinistra Mediante ERG mfERG Occhio Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | P1 波振幅^明适应型: Synonyms: L LT P1 型 P1 波振幅(波幅、 |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
96240-7 Right macula P1 implicit time --light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420851-0 P1 implicit time
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- P1 implicit time^light-adapted
- Property
- Time
- Time
- Pt
- System
- Macula.right
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Χρόνος μέγιστης P1^προσαρμογή στο φως: Synonyms: EYE EYE.ERG P1 Pt Qn Time Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Χρόνος μέγιστης P1 Ωχρά κηλίδα Ωχρά κηλίδα.δεξιά |
| es-MX | Spanish (Mexico) | P1 tiempo implícito^ adaptado a la luz: |
| it-IT | Italian (Italy) | P1, tempo implicito^adattato alla luce: Synonyms: Elettroretinogramma Macula destra Mediante ERG mfERG Occhio Punto nel tempo (episodio) Tempo (e.g. secondi) Tempo implicito P1 |
| zh-CN | Chinese (China) | P1 波潜伏时间^明适应型: Synonyms: P1 型 P1 波潜伏时间(潜伏期、 |
Example Units
| Unit | Source |
|---|---|
| ms | Example UCUM Units |
96241-5 Left macula P1 implicit time --light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420851-0 P1 implicit time
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- P1 implicit time^light-adapted
- Property
- Time
- Time
- Pt
- System
- Macula.left
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Χρόνος μέγιστης P1^προσαρμογή στο φως: Synonyms: EYE EYE.ERG P1 Pt Qn Time Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Χρόνος μέγιστης P1 Ωχρά κηλίδα Ωχρά κηλίδα.αριστερά |
| es-MX | Spanish (Mexico) | P1 tiempo implícito^ adaptado a la luz: |
| it-IT | Italian (Italy) | P1, tempo implicito^adattato alla luce: Synonyms: Elettroretinogramma Macula sinistra Mediante ERG mfERG Occhio Punto nel tempo (episodio) Tempo (e.g. secondi) Tempo implicito P1 |
| zh-CN | Chinese (China) | P1 波潜伏时间^明适应型: Synonyms: L LT P1 型 P1 波潜伏时间(潜伏期、 |
Example Units
| Unit | Source |
|---|---|
| ms | Example UCUM Units |
96232-4 Right macula N2 amplitude--light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420846-0 N2 amplitude
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- N2 amplitude^light-adapted
- Property
- Elpot
- Time
- Pt
- System
- Macula.right
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Εύρος N2^προσαρμογή στο φως: Synonyms: Elpot EYE EYE.ERG Pt Qn Εύρος N2 Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Ωχρά κηλίδα Ωχρά κηλίδα.δεξιά |
| es-MX | Spanish (Mexico) | Amplitud N2^ adaptado a la luz: |
| it-IT | Italian (Italy) | N2, ampiezza^adattato alla luce: Synonyms: Ampiezza N2 Elettroretinogramma Macula destra Mediante ERG mfERG Occhio Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | N2 波振幅^明适应型: Synonyms: N2 波振幅(波幅、 |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
96233-2 Left macula N2 amplitude--light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420846-0 N2 amplitude
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- N2 amplitude^light-adapted
- Property
- Elpot
- Time
- Pt
- System
- Macula.left
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Εύρος N2^προσαρμογή στο φως: Synonyms: Elpot EYE EYE.ERG Pt Qn Εύρος N2 Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Ωχρά κηλίδα Ωχρά κηλίδα.αριστερά |
| es-MX | Spanish (Mexico) | Amplitud N2^ adaptado a la luz: |
| it-IT | Italian (Italy) | N2, ampiezza^adattato alla luce: Synonyms: Ampiezza N2 Elettroretinogramma Macula sinistra Mediante ERG mfERG Occhio Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | N2 波振幅^明适应型: Synonyms: L LT N2 波振幅(波幅、 |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
96234-0 Right macula N2 implicit time --light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420850-2 N2 implicit time
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- N2 implicit time^light-adapted
- Property
- Time
- Time
- Pt
- System
- Macula.right
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Χρόνος μέγιστης Ν2^προσαρμογή στο φως: Synonyms: EYE EYE.ERG Pt Qn Time Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Χρόνος μέγιστης Ν2 Ωχρά κηλίδα Ωχρά κηλίδα.δεξιά |
| es-MX | Spanish (Mexico) | N2 tiempo implícito^ adaptado a la luz: |
| it-IT | Italian (Italy) | N2, tempo implicito^adattato alla luce: Synonyms: Elettroretinogramma Macula destra Mediante ERG mfERG Occhio Punto nel tempo (episodio) Tempo (e.g. secondi) Tempo implicito N2 |
| zh-CN | Chinese (China) | N2 波潜伏时间^明适应型: Synonyms: N2 波潜伏时间(潜伏期、 |
Example Units
| Unit | Source |
|---|---|
| ms | Example UCUM Units |
96235-7 Left macula N2 implicit time --light-adapted by mfERG
Part Descriptions
LP200598-3 light-adapted
Electrooculography (EOG) is a technique for measuring the resting potential of the retina. The EOG is used to assess the function of the pigment epithelium. During dark adaptation, the resting potential decreases slightly and reaches a minimum ("dark trough" or "Dt") after several minutes. When the light is switched on, a substantial increase of the resting potential occurs ("light peak" or "Lp"), which drops off after a few minutes when the retina adapts to the light. The ratio of the voltages (i.e., light peak divided by dark trough) is known as the Arden ratio and is normally above 1.80. The Arden ratio is often abnormal in retinitis pigmentosa, diabetic retinopathy, detached retina, Best disease and many other eye disorders.
Source: Regenstrief LOINC
LP420843-7 Electroretinogram.multifocal
A multifocal electroretinogram (mfERG) is a type of ERG. An ERG measures retinal electrical activity using a corneal electrode; an mfERG measures that activity in smaller areas of the retina in order to find local variation and pinpoint areas of dysfunction. PMID: 22038576
Source: Regenstrief LOINC
LP420850-2 N2 implicit time
The waveform found on a multifocal electroretinogram (mfERG) is typically a biphasic wave. The first deflection is negative, the second is positive, and the third is negative, and the three peaks are called N1, P1, and N2, respectively. The amplitude and implicit time can be measured for each, though P1 amplitude and implicit time are the most common measurements. PMID: 22038576
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- N2 implicit time^light-adapted
- Property
- Time
- Time
- Pt
- System
- Macula.left
- Scale
- Qn
- Method
- Electroretinogram.multifocal
Basic Attributes
- Class
- EYE.ERG
- Type
- Clinical
- First Released
- Version 2.69
- Last Updated
- Version 2.83 (MIN)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 96227-4 | Multifocal electroretinography (mfERG) panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Χρόνος μέγιστης Ν2^προσαρμογή στο φως: Synonyms: EYE EYE.ERG Pt Qn Time Ηλεκτροαμφιβληστροειδογράφημα Ηλεκτρορετινογράφημα.πολυεστιακό προσαρμογή στο φως Χρόνος μέγιστης Ν2 Ωχρά κηλίδα Ωχρά κηλίδα.αριστερά |
| es-MX | Spanish (Mexico) | N2 tiempo implícito^ adaptado a la luz: |
| it-IT | Italian (Italy) | N2, tempo implicito^adattato alla luce: Synonyms: Elettroretinogramma Macula sinistra Mediante ERG mfERG Occhio Punto nel tempo (episodio) Tempo (e.g. secondi) Tempo implicito N2 |
| zh-CN | Chinese (China) | N2 波潜伏时间^明适应型: Synonyms: L LT N2 波潜伏时间(潜伏期、 |
Example Units
| Unit | Source |
|---|---|
| ms | Example UCUM Units |