93236-8
aPTT.lupus sensitive.excess phospholipid in Platelet poor plasma by Coagulation assay --post heparin neutralization
Active
Term Description
Confirmatory lupus sensitive aPTT, measured after heparin neutralization, which removes the effects of any heparin that may be present in the sample. Heparin neutralization methods include the addition of heparinase, an enzyme that breaks down heparin, and heparin adsorption, in which a substance is added that binds the heparin that is present.
Source: Regenstrief LOINC
Part Descriptions
LP185878-8 Coagulation surface induced.lupus sensitive.excess phospholipid
Activated partial thromboplastic time with excess phospholipid is a confirmatory lab test for lupus anticoagulants (LA), which are phospholipid autoantibodies associated with excess clot formation, excess bleeding, and repeated miscarriages.Confirmatory testing measures aPTT in the presence of excess phospholipid, which saturates the antibody binding sites and thereby diminishes the inhibitory effect of the LA, resulting in a normalization of the aPTT. The aPTT screen to confirm ratio is calculated as Screen aPTT/Confirm aPTT, and the aPTT percent correction is calculated as [(Screen aPTT - Confirm aPTT)/Screen aPTT]x100.
PMID: 19624461
Source: Regenstrief LOINC, PMID: 19624461
LP411053-4 post heparin neutralization
The "post heparin neutralization" challenge in LOINC includes a variety of methods to remove the effect of heparin from a sample before testing. These methods include the addition of heparinase, an enzyme that breaks down heparin, and heparin adsorption, in which a substance is added that binds the heparin that is present.
Source: Regenstrief LOINC
Fully-Specified Name
- Component
- Coagulation surface induced.lupus sensitive.excess phospholipid^post heparin neutralization
- Property
- Time
- Time
- Pt
- System
- PPP
- Scale
- Qn
- Method
- Coag
Additional Names
- Short Name
- aPTT-LA confirm p hep neut PPP
- Display Name
- aPTT.lupus sensitive.excess phospholipid post heparin neutralization Coag (PPP) [Time]
- Consumer Name Alpha Get Info
- aPTT.lupus sensitive.excess phospholipid after heparin neutralization, Blood
Basic Attributes
- Class
- COAG
- Type
- Laboratory
- First Released
- Version 2.67
- Last Updated
- Version 2.67
- Order vs. Observation
- Observation
Member of these Panels
LOINC | Long Common Name |
---|---|
75515-7 | Lupus anticoagulant aPTT and dRVVT screening panel W Reflex |
75881-3 | Lupus anticoagulant aPTT, dRVVT and PT screening panel W Reflex |
Language Variants Get Info
Tag | Language | Translation |
---|---|---|
es-ES | Spanish (Spain) | Tiempo de tromboplastina parcial activada (aPTT). lupus sensible. exceso de fosfolípidos^Pos neutralización de heparina: Synonyms: Cuantitativo |
es-MX | Spanish (Mexico) | Superficie de coagulación inducida, sensible al lupus, exceso de fosfolípidos, después de la neutralización de heparina: |
fr-FR | French (France) | Temps de céphaline sensible aux anticoagulants circulants de type lupique avec excès de phospholipides après neutralisation à l'héparine: |
it-IT | Italian (Italy) | Coagulazione superficiale indotta.lupus sensibile.fosfolipidi in eccesso^post neutralizzazione di eparina: Synonyms: Neutralizzazione dell''eparina Plasma povero di piastrine Punto nel tempo (episodio) Studio di coagulazione Tempo (e.g. secondi) Tempo di tromboplastina parziale attivata (aPTT) Tempo di tromboplastina parziale attivata (aPTT).l Test di coagulazione |
zh-CN | Chinese (China) | 表面诱导型凝血过程.狼疮敏感性.过量磷脂^在肝素中和之后: Synonyms: APTT; |
Example Units
Unit | Source |
---|---|
s | Example UCUM Units |
LOINC Terminology Service (API) using HL7® FHIR® Get Info
Requests to this service require a free LOINC username and password. Below is a sample of the possible capabilities. See the LOINC Terminology Service documentation for more information.
- CodeSystem lookup
- https:
//fhir.loinc.org/CodeSystem/$lookup?system=http: //loinc.org&code=93236-8
LOINC Copyright
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright