99697-5
Permanent pacemaker panel
Active
99698-3 Permanent pacemaker Atrial stimulation setting
Term Description
This term represents the atrial stimulation setting for permanent (implanted) pacemakers. Temporary pacemaker atrial stimulation is measured in mA rather than mV and should be recorded using LOINC 99679-3.
Fully-Specified Name
- Component
- Atrial stimulation setting
- Property
- Elpot
- Time
- Pt
- System
- Pacemaker.permanent
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ρύθμιση κολπικής διέγερσης: Synonyms: Elpot Pt Qn Βηματοδότης Βηματοδότης.μόνιμος Πλαίσιο Ρύθμιση κολπικής διέγερσης ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Stimolazione atriale, setting: Synonyms: Dispositivi medici Pacemaker permanente Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) Setting stimolazione atriale, Impostazione stimolazione atriale |
| zh-CN | Chinese (China) | 心房刺激阈值: Synonyms: 伏特; |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
99699-1 Permanent pacemaker Atrial stimulation threshold
Term Description
This term represents the atrial stimulation threshold for permanent (implanted) pacemakers. Temporary pacemaker atrial stimulation threshold is measured in mA rather than mV and should be recorded using LOINC 99680-1.
Fully-Specified Name
- Component
- Atrial stimulation threshold
- Property
- Elpot
- Time
- Pt
- System
- Pacemaker.permanent
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Όριο κολπικής διέγερσης: Synonyms: Elpot Pt Qn Threshold Βηματοδότης Βηματοδότης.μόνιμος Όριο κολπικής διέγερσης ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Stimolazione atriale, soglia: Synonyms: Dispositivi medici Pacemaker permanente Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 心房刺激阈值: Synonyms: 伏特; |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
99700-7 Permanent pacemaker Ventricular stimulation setting
Term Description
This term represents the ventricular stimulation setting for permanent (implanted) pacemakers. Temporary pacemaker ventricular stimulation is measured in mA rather than mV and should be recorded using LOINC 99693-4.
Fully-Specified Name
- Component
- Ventricular stimulation setting
- Property
- Elpot
- Time
- Pt
- System
- Pacemaker.permanent
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ρύθμιση κοιλιακής διέγερσης: Synonyms: Elpot Pt Qn Βηματοδότης Βηματοδότης.μόνιμος Πλαίσιο Ρύθμιση κοιλιακής διέγερσης ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Stimolazione ventricolare, setting: Synonyms: Dispositivi medici Impostazione stimolazione ventricolare Pacemaker permanente Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) Setting stimolazione ventricolare |
| zh-CN | Chinese (China) | 心室刺激设置: Synonyms: 伏特; |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
99701-5 Permanent pacemaker Ventricular stimulation threshold
Term Description
This term represents the ventricular stimulation threshold for permanent (implanted) pacemakers. Temporary pacemaker ventricular stimulation threshold is measured in mA rather than mV and should be recorded using LOINC 99694-2.
Fully-Specified Name
- Component
- Ventricular stimulation threshold
- Property
- Elpot
- Time
- Pt
- System
- Pacemaker.permanent
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Όριο κοιλιακής διέγερσης: Synonyms: Elpot Pt Qn Threshold Βηματοδότης Βηματοδότης.μόνιμος Όριο κοιλιακής διέγερσης ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Stimolazione ventricolare, soglia: Synonyms: Dispositivi medici Pacemaker permanente Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) Soglia stimolazione ventricolare |
| zh-CN | Chinese (China) | 心室刺激阈值: Synonyms: 伏特; |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
99675-1 Pacemaker Atrial electrical activity captured
Fully-Specified Name
- Component
- Atrial electrical activity captured
- Property
- Find
- Time
- Pt
- System
- Pacemaker
- Scale
- Ord
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Example Answer List LL361-7
| Answer | Code | Score | Answer ID |
|---|---|---|---|
| Yes Copyright http://snomed.info/sct ID:373066001 Yes (qualifier value) | LA33-6 | ||
| No Copyright http://snomed.info/sct ID:373067005 No (qualifier value) | LA32-8 |
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Λήψη κολπικής ηλεκτρικής δραστηριότητας: Synonyms: Ord Pt Βηματοδότης Δραστηριότητα Εύρεση Λήψη κολπικής ηλεκτρικής δραστηριότητας ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Attività elettrica atriale catturata: Synonyms: Dispositivi medici Osservazione Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 捕获到心房电活动: Synonyms: 依次型; |
Third Party Copyright
This material includes SNOMED Clinical Terms® (SNOMED CT®) which is used by permission of the International Health Terminology Standards Development Organisation (IHTSDO) under license. All rights reserved. SNOMED CT® was originally created by The College of American Pathologists. "SNOMED" and "SNOMED CT" are registered trademarks of the IHTSDO.
This material includes content from the US Edition to SNOMED CT, which is developed and maintained by the U.S. National Library of Medicine and is available to authorized UMLS Metathesaurus Licensees from the UTS Downloads site at https://uts.nlm.nih.gov.
Use of SNOMED CT content is subject to the terms and conditions set forth in the SNOMED CT Affiliate License Agreement. It is the responsibility of those implementing this product to ensure they are appropriately licensed and for more information on the license, including how to register as an Affiliate Licensee, please refer to https://www.snomed.org/get-snomed or [email protected]<mailto:[email protected]>. This may incur a fee in SNOMED International non-Member countries.
99676-9 Pacemaker Atrial electrical activity sensed
Fully-Specified Name
- Component
- Atrial electrical activity sensed
- Property
- Find
- Time
- Pt
- System
- Pacemaker
- Scale
- Ord
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Example Answer List LL361-7
| Answer | Code | Score | Answer ID |
|---|---|---|---|
| Yes Copyright http://snomed.info/sct ID:373066001 Yes (qualifier value) | LA33-6 | ||
| No Copyright http://snomed.info/sct ID:373067005 No (qualifier value) | LA32-8 |
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ανίχνευση κολπικής ηλεκτρικής δραστηριότητας: Synonyms: Ord Pt Ανίχνευση κολπικής ηλεκτρικής δραστηριότητας Βηματοδότης Δραστηριότητα Εύρεση ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Attività elettrica atriale rilevata: Synonyms: Dispositivi medici Osservazione Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 感应到心房电活动: Synonyms: 依次型; |
Third Party Copyright
This material includes SNOMED Clinical Terms® (SNOMED CT®) which is used by permission of the International Health Terminology Standards Development Organisation (IHTSDO) under license. All rights reserved. SNOMED CT® was originally created by The College of American Pathologists. "SNOMED" and "SNOMED CT" are registered trademarks of the IHTSDO.
This material includes content from the US Edition to SNOMED CT, which is developed and maintained by the U.S. National Library of Medicine and is available to authorized UMLS Metathesaurus Licensees from the UTS Downloads site at https://uts.nlm.nih.gov.
Use of SNOMED CT content is subject to the terms and conditions set forth in the SNOMED CT Affiliate License Agreement. It is the responsibility of those implementing this product to ensure they are appropriately licensed and for more information on the license, including how to register as an Affiliate Licensee, please refer to https://www.snomed.org/get-snomed or [email protected]<mailto:[email protected]>. This may incur a fee in SNOMED International non-Member countries.
99677-7 Pacemaker Atrial sensitivity setting
Fully-Specified Name
- Component
- Atrial sensitivity setting
- Property
- Elpot
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ρύθμιση κολπικής ευαισθησίας: Synonyms: Elpot Pt Qn Βηματοδότης Πλαίσιο Ρύθμιση κολπικής ευαισθησίας ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Sensibilità atriale, setting: Synonyms: Dispositivi medici Impostazione sensibilità atriale Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) Setting sensibilità atriale |
| zh-CN | Chinese (China) | 心房电活动设置: Synonyms: 伏特; |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
99678-5 Pacemaker Atrial sensitivity threshold
Fully-Specified Name
- Component
- Atrial sensitivity threshold
- Property
- Elpot
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Όριο κολπικής ευαισθησίας: Synonyms: Elpot Pt Qn Threshold Βηματοδότης Όριο κολπικής ευαισθησίας ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Sensibilità atriale, soglia: Synonyms: Dispositivi medici Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 心房电活动阈值: Synonyms: 伏特; |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
99681-9 Pacemaker Atrial wire
Fully-Specified Name
- Component
- Atrial wire
- Property
- Num
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Κολπικό καλώδιο: Synonyms: Pt Qn Αρ. Βηματοδότης Κολπικό καλώδιο ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Cavo atriale: Synonyms: Dispositivi medici Numero (conta) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 心房导线: Synonyms: 个数; |
Example Units
| Unit | Source |
|---|---|
| {#} | Example UCUM Units |
99682-7 Pacemaker Atrioventricular interval
Fully-Specified Name
- Component
- Atrioventricular interval
- Property
- Time
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Κολποκοιλιακό διάστημα: Synonyms: Pt Qn Time Βηματοδότης Κολποκοιλιακό διάστημα ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Intervallo atrioventricolare: Synonyms: Dispositivi medici Punto nel tempo (episodio) Tempo (e.g. secondi) |
| zh-CN | Chinese (China) | 房室间期: Synonyms: 可用数量表示的; |
Example Units
| Unit | Source |
|---|---|
| ms | Example UCUM Units |
99683-5 Pacemaker Ground wire
Fully-Specified Name
- Component
- Ground wire
- Property
- Num
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Καλώδιο γείωσης: Synonyms: Pt Qn Αρ. Βηματοδότης Καλώδιο γείωσης ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Filo di terra: Synonyms: Dispositivi medici Numero (conta) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 地线: Synonyms: 个数; |
Example Units
| Unit | Source |
|---|---|
| {#} | Example UCUM Units |
99684-3 Pacemaker mode
Fully-Specified Name
- Component
- Pacemaker mode
- Property
- Type
- Time
- Pt
- System
- Pacemaker
- Scale
- Nom
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Example Answer List LL6145-8
| Answer | Code | Score | Answer ID |
|---|---|---|---|
| Atrial asynchronous | LA33046-6 | ||
| Atrial demand | LA33047-4 | ||
| Ventricular asynchronous | LA33048-2 | ||
| Ventricular demand | LA33052-4 | ||
| Dual chamber asynchronous | LA33049-0 | ||
| Dual chamber demand | LA33051-6 |
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Λειτουργία βηματοδότη: Synonyms: Nom Pt Type Βηματοδότης Λειτουργία βηματοδότη ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Pacemaker, modalità: Synonyms: Dispositivi medici Modalità del pacemaker Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 起搏器模式: Synonyms: 分类型应答; |
99685-0 Pacemaker rate
Fully-Specified Name
- Component
- Pacemaker rate
- Property
- NRat
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ρυθμός βηματοδότη: Synonyms: NRat Pt Qn Αξία Βηματοδότης Ρυθμός βηματοδότη ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Pacemaker, frequenza: Synonyms: Dispositivi medici Frequenza del pacemaker Indice numerico Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 起搏器速率: Synonyms: 单位时间内的数量或计数; |
Example Units
| Unit | Source |
|---|---|
| {beats}/min | Example UCUM Units |
99686-8 Pacemaker type
Fully-Specified Name
- Component
- Pacemaker type
- Property
- Type
- Time
- Pt
- System
- Pacemaker
- Scale
- Nom
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Example Answer List LL6146-6
| Answer | Code | Score | Answer ID |
|---|---|---|---|
| Single chamber | LA33053-2 | ||
| Dual chamber | LA33054-0 | ||
| Biventricular | LA33055-7 |
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Τύπος βηματοδότη: Synonyms: Nom Pt Type Βηματοδότης ΣΥΣΚΕΥΕΣ Τύπος βηματοδότη |
| it-IT | Italian (Italy) | Pacemaker, tipo: Synonyms: Dispositivi medici Punto nel tempo (episodio) Tipo di pacemaker |
| zh-CN | Chinese (China) | 起搏器类型: Synonyms: 分类型应答; |
99688-4 Pacemaker Post-ventricular atrial refractory period setting
Fully-Specified Name
- Component
- Post-ventricular atrial refractory period setting
- Property
- Time
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ρύθμιση μετακοιλιακής κολπικής ανερέθιστης περιόδου: Synonyms: Pt Qn Time Βηματοδότης Πλαίσιο Ρύθμιση μετακοιλιακής κολπικής ανερέθιστης περιόδου ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Periodo refrattario atriale post-ventricolare, setting: Synonyms: Dispositivi medici Punto nel tempo (episodio) Setting periodo refrattario atriale post-ventricolare Tempo (e.g. secondi) |
| zh-CN | Chinese (China) | 心室后心房不应期设置: Synonyms: XXX刺激 - 在...之后 之后于... 可用数量表示的; |
Example Units
| Unit | Source |
|---|---|
| ms | Example UCUM Units |
99689-2 Pacemaker Ventricular electrical activity captured
Fully-Specified Name
- Component
- Ventricular electrical activity captured
- Property
- Find
- Time
- Pt
- System
- Pacemaker
- Scale
- Ord
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Example Answer List LL361-7
| Answer | Code | Score | Answer ID |
|---|---|---|---|
| Yes Copyright http://snomed.info/sct ID:373066001 Yes (qualifier value) | LA33-6 | ||
| No Copyright http://snomed.info/sct ID:373067005 No (qualifier value) | LA32-8 |
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Λήψη κοιλιακής ηλεκτρικής δραστηριότητας: Synonyms: Ord Pt Βηματοδότης Δραστηριότητα Εύρεση Λήψη κοιλιακής ηλεκτρικής δραστηριότητας ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Attività elettrica ventricolare catturata: Synonyms: Dispositivi medici Osservazione Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 捕获到心室电活动: Synonyms: 依次型; |
Third Party Copyright
This material includes SNOMED Clinical Terms® (SNOMED CT®) which is used by permission of the International Health Terminology Standards Development Organisation (IHTSDO) under license. All rights reserved. SNOMED CT® was originally created by The College of American Pathologists. "SNOMED" and "SNOMED CT" are registered trademarks of the IHTSDO.
This material includes content from the US Edition to SNOMED CT, which is developed and maintained by the U.S. National Library of Medicine and is available to authorized UMLS Metathesaurus Licensees from the UTS Downloads site at https://uts.nlm.nih.gov.
Use of SNOMED CT content is subject to the terms and conditions set forth in the SNOMED CT Affiliate License Agreement. It is the responsibility of those implementing this product to ensure they are appropriately licensed and for more information on the license, including how to register as an Affiliate Licensee, please refer to https://www.snomed.org/get-snomed or [email protected]<mailto:[email protected]>. This may incur a fee in SNOMED International non-Member countries.
99690-0 Pacemaker Ventricular electrical activity sensed
Fully-Specified Name
- Component
- Ventricular electrical activity sensed
- Property
- Find
- Time
- Pt
- System
- Pacemaker
- Scale
- Ord
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Example Answer List LL361-7
| Answer | Code | Score | Answer ID |
|---|---|---|---|
| Yes Copyright http://snomed.info/sct ID:373066001 Yes (qualifier value) | LA33-6 | ||
| No Copyright http://snomed.info/sct ID:373067005 No (qualifier value) | LA32-8 |
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ανίχνευση κοιλιακής ηλεκτρικής δραστηριότητας: Synonyms: Ord Pt Ανίχνευση κοιλιακής ηλεκτρικής δραστηριότητας Βηματοδότης Δραστηριότητα Εύρεση ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Attività elettrica ventricolare rilevata: Synonyms: Dispositivi medici Osservazione Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 感应到心室电活动: Synonyms: 依次型; |
Third Party Copyright
This material includes SNOMED Clinical Terms® (SNOMED CT®) which is used by permission of the International Health Terminology Standards Development Organisation (IHTSDO) under license. All rights reserved. SNOMED CT® was originally created by The College of American Pathologists. "SNOMED" and "SNOMED CT" are registered trademarks of the IHTSDO.
This material includes content from the US Edition to SNOMED CT, which is developed and maintained by the U.S. National Library of Medicine and is available to authorized UMLS Metathesaurus Licensees from the UTS Downloads site at https://uts.nlm.nih.gov.
Use of SNOMED CT content is subject to the terms and conditions set forth in the SNOMED CT Affiliate License Agreement. It is the responsibility of those implementing this product to ensure they are appropriately licensed and for more information on the license, including how to register as an Affiliate Licensee, please refer to https://www.snomed.org/get-snomed or [email protected]<mailto:[email protected]>. This may incur a fee in SNOMED International non-Member countries.
99691-8 Pacemaker Ventricular sensitivity setting
Fully-Specified Name
- Component
- Ventricular sensitivity setting
- Property
- Elpot
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Ρύθμιση κοιλιακής ευαισθησίας: Synonyms: Elpot Pt Qn Βηματοδότης Πλαίσιο Ρύθμιση κοιλιακής ευαισθησίας ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Sensibilità ventricolare, setting: Synonyms: Dispositivi medici Impostazione sensibilità ventricolare Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) Setting sensibilità ventricolare |
| zh-CN | Chinese (China) | 心室敏感性设置: Synonyms: 伏特; |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
99692-6 Pacemaker Ventricular sensitivity threshold
Fully-Specified Name
- Component
- Ventricular sensitivity threshold
- Property
- Elpot
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Όριο κοιλιακής ευαισθησίας: Synonyms: Elpot Pt Qn Threshold Βηματοδότης Όριο κοιλιακής ευαισθησίας ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Sensibilità ventricolare, soglia: Synonyms: Dispositivi medici Potenziale Elettrico (Voltaggio) Punto nel tempo (episodio) Soglia sensibilità ventricolare |
| zh-CN | Chinese (China) | 心室敏感性阈值: Synonyms: 伏特; |
Example Units
| Unit | Source |
|---|---|
| mV | Example UCUM Units |
99695-9 Pacemaker Ventricular wire
Fully-Specified Name
- Component
- Ventricular wire
- Property
- Num
- Time
- Pt
- System
- Pacemaker
- Scale
- Qn
- Method
Basic Attributes
- Class
- DEVICES
- Type
- Clinical
- First Released
- Version 2.72
- Last Updated
- Version 2.72 (ADD)
- Order vs. Observation
- Observation
Member of these Panels
| LOINC | Long Common Name |
|---|---|
| 99697-5 | Permanent pacemaker panel |
| 99674-4 | Temporary pacemaker panel |
Language Variants Get Info
| Tag | Language | Translation |
|---|---|---|
| el-GR | Greek (Greece) | Κοιλιακό σύρμα: Synonyms: Pt Qn Αρ. Βηματοδότης Κοιλιακό σύρμα ΣΥΣΚΕΥΕΣ |
| it-IT | Italian (Italy) | Filo ventricolare: Synonyms: Dispositivi medici Numero (conta) Punto nel tempo (episodio) |
| zh-CN | Chinese (China) | 心室导线: Synonyms: 个数; |
Example Units
| Unit | Source |
|---|---|
| {#} | Example UCUM Units |